472 related articles for article (PubMed ID: 7699089)
21. Comparative study of power-based versus mean frequency-based transcranial color-coded duplex sonography in normal adults.
Baumgartner RW; Schmid C; Baumgartner I
Stroke; 1996 Jan; 27(1):101-4. PubMed ID: 8553384
[TBL] [Abstract][Full Text] [Related]
22. Clinical applications of transcranial color-coded duplex sonography.
Krejza J; Baumgartner RW
J Neuroimaging; 2004 Jul; 14(3):215-25. PubMed ID: 15228761
[TBL] [Abstract][Full Text] [Related]
23. Transcranial harmonic power duplex sonography for the evaluation of cerebral arteries.
Seidel G; Christoph A; Algermissen C; Katzer T; Claasen L; Vidal-Langwasser M
J Neuroimaging; 2000 Oct; 10(4):216-20. PubMed ID: 11147400
[TBL] [Abstract][Full Text] [Related]
24. Transcranial color-coded real-time sonography of intracranial veins. Normal values of blood flow velocities and findings in superior sagittal sinus thrombosis.
Becker G; Bogdahn U; Gehlberg C; Fröhlich T; Hofmann E; Schlief MD
J Neuroimaging; 1995 Apr; 5(2):87-94. PubMed ID: 7718947
[TBL] [Abstract][Full Text] [Related]
25. Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters.
Krejza J; Mariak Z; Walecki J; Szydlik P; Lewko J; Ustymowicz A
AJR Am J Roentgenol; 1999 Jan; 172(1):213-8. PubMed ID: 9888770
[TBL] [Abstract][Full Text] [Related]
26. A validation study on the intraobserver reproducibility of transcranial color-coded duplex sonography velocity measurements.
Baumgartner RW; Mathis J; Sturzenegger M; Mattle HP
Ultrasound Med Biol; 1994; 20(3):233-7. PubMed ID: 7914715
[TBL] [Abstract][Full Text] [Related]
27. Evaluation of posterior cerebral artery blood flow with transcranial Doppler sonography: value and risk of common carotid artery compression.
Jatuzis D; Zachrisson H; Blomstrand C; Ekholm S; Holm J; Volkmann R
J Clin Ultrasound; 2000; 28(9):452-60. PubMed ID: 11056022
[TBL] [Abstract][Full Text] [Related]
28. Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults.
Schöning M; Walter J
Stroke; 1992 Sep; 23(9):1280-6. PubMed ID: 1519283
[TBL] [Abstract][Full Text] [Related]
29. Normal blood flow velocities of basal cerebral arteries decrease with advancing age: a transcranial Doppler sonography study.
Demirkaya S; Uluc K; Bek S; Vural O
Tohoku J Exp Med; 2008 Feb; 214(2):145-9. PubMed ID: 18285672
[TBL] [Abstract][Full Text] [Related]
30. Transcranial color-coded duplex sonography of intracranial veins and sinuses in adults. Reference data from 130 volunteers.
Stolz E; Kaps M; Kern A; Babacan SS; Dorndorf W
Stroke; 1999 May; 30(5):1070-5. PubMed ID: 10229746
[TBL] [Abstract][Full Text] [Related]
31. Comparison between magnetic resonance phase contrast imaging and transcranial Doppler ultrasound with regard to blood flow velocity in intracranial arteries: work in progress.
Seitz J; Strotzer M; Schlaier J; Nitz WR; Völk M; Feuerbach S
J Neuroimaging; 2001 Apr; 11(2):121-8. PubMed ID: 11296580
[TBL] [Abstract][Full Text] [Related]
32. The prognostic value of early transcranial Doppler ultrasound following cardiopulmonary resuscitation.
Wessels T; Harrer JU; Jacke C; Janssens U; Klötzsch C
Ultrasound Med Biol; 2006 Dec; 32(12):1845-51. PubMed ID: 17169697
[TBL] [Abstract][Full Text] [Related]
33. Transcranial color duplex sonography of basal cerebral arteries: reference data of flow velocities from childhood to adulthood.
Schöning M; Niemann G; Hartig B
Neuropediatrics; 1996 Oct; 27(5):249-55. PubMed ID: 8971745
[TBL] [Abstract][Full Text] [Related]
34. Transcranial doppler ultrasonography cerebral blood flow dynamics study of neurosurgical patients in peri-agonal period with fixed dilated or non-reacting pupils.
Shrestha P; Ansari SR; Ghimire RK; Gongal DN; Devkota UP
Br J Neurosurg; 2018 Apr; 32(2):182-187. PubMed ID: 29693475
[TBL] [Abstract][Full Text] [Related]
35. Transcranial ultrasonography of cerebral veins and sinuses.
Schreiber SJ; Stolz E; Valdueza JM
Eur J Ultrasound; 2002 Nov; 16(1-2):59-72. PubMed ID: 12470851
[TBL] [Abstract][Full Text] [Related]
36. Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.
Baumgartner RW; Mattle HP; Schroth G
Stroke; 1999 Jan; 30(1):87-92. PubMed ID: 9880394
[TBL] [Abstract][Full Text] [Related]
37. Transiently increased basilar artery flow velocity following severe head injury: a time course transcranial Doppler study.
Hadani M; Bruk B; Ram Z; Knoller N; Bass A
J Neurotrauma; 1997 Sep; 14(9):629-36. PubMed ID: 9337125
[TBL] [Abstract][Full Text] [Related]
38. Suitability of temporal bone acoustic window: conventional TCD versus transcranial color-coded duplex sonography.
Krejza J; Swiat M; Pawlak MA; Oszkinis G; Weigele J; Hurst RW; Kasner S
J Neuroimaging; 2007 Oct; 17(4):311-4. PubMed ID: 17894619
[TBL] [Abstract][Full Text] [Related]
39. Color Doppler sonographic evaluation of collateral circulation in patients with cerebral aneurysms and the occlusion of the brachiocephalic vessels.
Kaspera W; Majchrzak H; Ladziński P; Tomalski W
Neurosurgery; 2005 Dec; 57(6):1117-26; discussion 1117-26. PubMed ID: 16331159
[TBL] [Abstract][Full Text] [Related]
40. Transcranial color-coded duplex sonography in unilateral flow-restrictive extracranial carotid artery disease.
Baumgartner RW; Baumgartner I; Mattle HP; Schroth G
AJNR Am J Neuroradiol; 1996 Apr; 17(4):777-83. PubMed ID: 8730200
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]