These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Evaluation of One Touch II hospital in a community-hospital setting. Hijazi BE; Peddicord C Clin Lab Sci; 1995; 8(6):365-8. PubMed ID: 10163343 [TBL] [Abstract][Full Text] [Related]
23. Clinical evaluation of a novel test strip technology for blood glucose monitoring: accuracy at hypoglycaemic glucose levels. Bellary S; Cameron H; Macleod K; Malecha M; Koria K; Raja P; Cabezudo JD; Ellison J Diabetes Res Clin Pract; 2012 Dec; 98(3):430-5. PubMed ID: 23063304 [TBL] [Abstract][Full Text] [Related]
25. Performance of a new blood glucose monitoring system in the hands of intended users. Bailey TS; Wallace JF; Parkes JL; Pardo S; Yu J; Schachner HC; Simmons DA; Chu A Diabetes Technol Ther; 2012 Sep; 14(9):783-9. PubMed ID: 22746838 [TBL] [Abstract][Full Text] [Related]
26. Correlation of capillary and venous blood glucometry with laboratory determination. Kumar G; Sng BL; Kumar S Prehosp Emerg Care; 2004; 8(4):378-83. PubMed ID: 15625997 [TBL] [Abstract][Full Text] [Related]
28. [Evaluation of accuracy and influence factors of bedside blood glucose monitoring in critically ill patients]. Feng T; Cao XY Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2012 Aug; 24(8):482-6. PubMed ID: 22871408 [TBL] [Abstract][Full Text] [Related]
29. The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Mastrototaro J; Shin J; Marcus A; Sulur G; Diabetes Technol Ther; 2008 Oct; 10(5):385-90. PubMed ID: 18715215 [TBL] [Abstract][Full Text] [Related]
30. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense). Dimeski G; Jones BW; Tilley V; Greenslade MN; Russell AW Ann Clin Biochem; 2010 Jul; 47(Pt 4):358-65. PubMed ID: 20592335 [TBL] [Abstract][Full Text] [Related]
31. Laboratory assessment of three glucometers. Ajala MO; Oladipo OO; Fasanmade O; Adewole TA Afr J Med Med Sci; 2003 Sep; 32(3):279-82. PubMed ID: 15030088 [TBL] [Abstract][Full Text] [Related]
32. Comparative accuracy of glucose monitors. Fanghänel G; Sanchez-Reyes L; Morales M; Torres E; Chavira J; Sotres D; Valles V Arch Med Res; 1998; 29(4):325-9. PubMed ID: 9887551 [TBL] [Abstract][Full Text] [Related]
33. The validity of the Medisafe self-monitoring blood glucose system. Nillakupt K; Nathalang O; Arnutti P; Rangsin R Diabetes Technol Ther; 2002; 4(5):615-21. PubMed ID: 12450442 [TBL] [Abstract][Full Text] [Related]
34. Bedside glucose monitoring. Comparison of performance as studied by the College of American Pathologists Q-Probes program. Howanitz PJ; Jones BA Arch Pathol Lab Med; 1996 Apr; 120(4):333-8. PubMed ID: 8619743 [TBL] [Abstract][Full Text] [Related]
35. Accuracy of home blood glucose monitors using forearm blood samples: FreeStyle versus One Touch Ultra. Demers J; Kane MP; Bakst G; Busch RS; Hamilton RA Am J Health Syst Pharm; 2003 Jun; 60(11):1130-5. PubMed ID: 12816023 [TBL] [Abstract][Full Text] [Related]
36. Acceptability of capillary blood glucose testing with Companion 2 after intensive individual patient training. Kabadi UM; Kabadi M; O'Connell KM Diabetes Res; 1994; 26(1):25-32. PubMed ID: 7664534 [TBL] [Abstract][Full Text] [Related]
37. Capillary blood glucose screening (Accu-Chek Advantage) for gestational diabetes. Srimaekarat T J Med Assoc Thai; 2009 Oct; 92(10):1268-72. PubMed ID: 19845232 [TBL] [Abstract][Full Text] [Related]
38. Bedside capillary blood glucose measurements in critically ill patients: influence of catecholamine therapy. Fekih Hassen M; Ayed S; Gharbi R; Ben Sik Ali H; Marghli S; Elatrous S Diabetes Res Clin Pract; 2010 Jan; 87(1):87-91. PubMed ID: 19853946 [TBL] [Abstract][Full Text] [Related]
39. Assessment of glucose meter performance at the antenatal diabetes clinic: exploration of patient-related and pre-analytical factors. Parwaiz M; Lunt H; Florkowski CM; Logan FJ; Irons L; Perwick C; Frampton CM; Moore MP Ann Clin Biochem; 2014 Jan; 51(Pt 1):47-53. PubMed ID: 24003257 [TBL] [Abstract][Full Text] [Related]