These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 7706333)

  • 21. Hydroxyapatite-electroplated cp-titanium implant and its bone integration potentiality: an in vivo study.
    Badr NA; El Hadary AA
    Implant Dent; 2007 Sep; 16(3):297-308. PubMed ID: 17846546
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of hydroxyapatite/tricalcium-phosphate coating on osseointegration of plasma-sprayed titanium alloy implants.
    Stewart M; Welter JF; Goldberg VM
    J Biomed Mater Res A; 2004 Apr; 69(1):1-10. PubMed ID: 14999745
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of hydrosyapatite coating on Ti-6A1-4V implant-site infection in a rabbit tibial model.
    Vogely HC; Oosterbos CJ; Puts EW; Nijhof MW; Nikkels PG; Fleer A; Tonino AJ; Dhert WJ; Verbout AJ
    J Orthop Res; 2000 May; 18(3):485-93. PubMed ID: 10937638
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Gap healing enhanced by hydroxyapatite coating in dogs.
    Søballe K; Hansen ES; Brockstedt-Rasmussen H; Hjortdal VE; Juhl GI; Pedersen CM; Hvid I; Bünger C
    Clin Orthop Relat Res; 1991 Nov; (272):300-7. PubMed ID: 1657476
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs.
    Søballe K; Brockstedt-Rasmussen H; Hansen ES; Bünger C
    Acta Orthop Scand; 1992 Apr; 63(2):128-40. PubMed ID: 1590045
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Scanning electron microscopic study of titanium-hydroxyapatite, the functionally graded-material implanted in rabbits].
    Tang XJ; Xing SZ; Song XL; Gui L; Chu CL
    Zhonghua Zheng Xing Wai Ke Za Zhi; 2005 Nov; 21(6):415-7. PubMed ID: 16463775
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Histological and mechanical comparison of hydroxyapatite-coated cobalt-chrome and titanium implants in the rabbit femur.
    Friedman RJ; Bauer TW; Garg K; Jiang M; An YH; Draughn RA
    J Appl Biomater; 1995; 6(4):231-5. PubMed ID: 8589507
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions.
    Søballe K; Hansen ES; B-Rasmussen H; Jørgensen PH; Bünger C
    J Orthop Res; 1992 Mar; 10(2):285-99. PubMed ID: 1311039
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Quantitative analysis of in vivo tissue responses to titanium-oxide- and hydroxyapatite-coated titanium alloy.
    Hayashi K; Uenoyama K; Matsuguchi N; Sugioka Y
    J Biomed Mater Res; 1991 Apr; 25(4):515-23. PubMed ID: 2050714
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Osteoblast response and osseointegration of a Ti-6Al-4V alloy implant incorporating strontium.
    Park JW; Kim HK; Kim YJ; Jang JH; Song H; Hanawa T
    Acta Biomater; 2010 Jul; 6(7):2843-51. PubMed ID: 20085830
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Histologic investigation of the biologic behavior of different hydroxyapatite plasma-sprayed coatings in rabbits.
    Jansen JA; van der Waerden JP; Wolke JG
    J Biomed Mater Res; 1993 May; 27(5):603-10. PubMed ID: 8314812
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [In vivo effect of nanophase Ti6Al4V on osseointegration: experiment with rabbits].
    Han P; Ji WP; Jiang Y; Zhao CL; Zhang XN
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(25):1767-71. PubMed ID: 19035089
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Defective implant osseointegration under protein undernutrition: prevention by PTH or pamidronate.
    Dayer R; Badoud I; Rizzoli R; Ammann P
    J Bone Miner Res; 2007 Oct; 22(10):1526-33. PubMed ID: 17563238
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Adjuvant therapies of bone graft around non-cemented experimental orthopedic implants stereological methods and experiments in dogs.
    Baas J
    Acta Orthop Suppl; 2008 Aug; 79(330):1-43. PubMed ID: 19065776
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of surface topology on the osseointegration of implant materials in trabecular bone.
    Wong M; Eulenberger J; Schenk R; Hunziker E
    J Biomed Mater Res; 1995 Dec; 29(12):1567-75. PubMed ID: 8600147
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A long-term study on defect filling and bone ingrowth using a canine fiber metal total hip model.
    Greis PE; Kang JD; Silvaggio V; Rubash HE
    Clin Orthop Relat Res; 1992 Jan; (274):47-59. PubMed ID: 1729022
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Porous titanium granules promote bone healing and growth in rabbit tibia peri-implant osseous defects.
    Wohlfahrt JC; Monjo M; Rønold HJ; Aass AM; Ellingsen JE; Lyngstadaas SP
    Clin Oral Implants Res; 2010 Feb; 21(2):165-73. PubMed ID: 19912270
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Histological reaction to titanium alloy and hydroxyapatite particles in the rabbit tibia.
    Goodman SB; Davidson JA; Fornasier VL
    Biomaterials; 1993 Aug; 14(10):723-8. PubMed ID: 8218720
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.