These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 7706570)
41. Spontaneous breathing trial and post-extubation work of breathing in morbidly obese critically ill patients. Mahul M; Jung B; Galia F; Molinari N; de Jong A; Coisel Y; Vaschetto R; Matecki S; Chanques G; Brochard L; Jaber S Crit Care; 2016 Oct; 20(1):346. PubMed ID: 27784322 [TBL] [Abstract][Full Text] [Related]
42. Modeling the effect of progressive endotracheal tube occlusion on tidal volume in pressure-control mode. Tung A; Morgan SE Anesth Analg; 2002 Jul; 95(1):192-7, table of contents. PubMed ID: 12088967 [TBL] [Abstract][Full Text] [Related]
43. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system. Banner MJ; Blanch PB; Kirby RR Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467 [TBL] [Abstract][Full Text] [Related]
44. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate. Ivanov VA Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200 [TBL] [Abstract][Full Text] [Related]
45. Clinical evaluation of the v-gel supraglottic airway device in comparison with a classical laryngeal mask and endotracheal intubation in cats during spontaneous and controlled mechanical ventilation. Prasse SA; Schrack J; Wenger S; Mosing M Vet Anaesth Analg; 2016 Jan; 43(1):55-62. PubMed ID: 25819338 [TBL] [Abstract][Full Text] [Related]
47. Perioperative evaluation of respiratory impedance using the forced oscillation technique: a prospective observational study. Nakano S; Nakahira J; Sawai T; Kuzukawa Y; Ishio J; Minami T BMC Anesthesiol; 2016 Jul; 16(1):32. PubMed ID: 27389091 [TBL] [Abstract][Full Text] [Related]
48. Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes. Guttmann J; Kessler V; Mols G; Hentschel R; Haberthür C; Geiger K Crit Care Med; 2000 Apr; 28(4):1018-26. PubMed ID: 10809276 [TBL] [Abstract][Full Text] [Related]
49. Gas flow between coaxial tubes: impedance to gas flow in an endotracheal tube increases with a catheter within. Magee PT Proc Inst Mech Eng H; 2012 Jun; 226(6):491-4. PubMed ID: 22783765 [TBL] [Abstract][Full Text] [Related]
50. Respiratory mechanics by least squares fitting in mechanically ventilated patients: applications during paralysis and during pressure support ventilation. Iotti GA; Braschi A; Brunner JX; Smits T; Olivei M; Palo A; Veronesi R Intensive Care Med; 1995 May; 21(5):406-13. PubMed ID: 7665750 [TBL] [Abstract][Full Text] [Related]
51. Impact of endotracheal tube biofilm and respiratory secretions on airway resistance and mechanics of breathing in a neonatal lung model. Kenaley KM; Blackson T; Boylan L; Ciarlo J; Antunes M; Shaffer TH; Locke R J Appl Physiol (1985); 2018 Oct; 125(4):1227-1231. PubMed ID: 30048200 [TBL] [Abstract][Full Text] [Related]
52. Direct tracheal airway pressure measurements are essential for safe and accurate dynamic monitoring of respiratory mechanics. A laboratory study. Kárason S; Søndergaard S; Lundin S; Wiklund J; Stenqvist O Acta Anaesthesiol Scand; 2001 Feb; 45(2):173-9. PubMed ID: 11167162 [TBL] [Abstract][Full Text] [Related]
53. Intratracheal pulmonary ventilation in a rabbit lung injury model: continuous airway pressure monitoring and gas exchange efficacy. Hon EK; Hultquist KA; Loescher T; Raszynski A; Torbati D; Tabares C; Wolfsdorf J Crit Care Med; 2000 Jul; 28(7):2480-5. PubMed ID: 10921582 [TBL] [Abstract][Full Text] [Related]
54. Extubation after breathing trials with automatic tube compensation, T-tube, or pressure support ventilation. Haberthür C; Mols G; Elsasser S; Bingisser R; Stocker R; Guttmann J Acta Anaesthesiol Scand; 2002 Sep; 46(8):973-9. PubMed ID: 12190798 [TBL] [Abstract][Full Text] [Related]
55. Peak airway pressure increase is a late warning sign of partial endotracheal tube obstruction whereas change in expiratory flow is an early warning sign. Kawati R; Lattuada M; Sjöstrand U; Guttmann J; Hedenstierna G; Helmer A; Lichtwarck-Aschoff M Anesth Analg; 2005 Mar; 100(3):889-893. PubMed ID: 15728085 [TBL] [Abstract][Full Text] [Related]
56. Suctioning through a double-lumen endotracheal tube helps to prevent alveolar collapse and to preserve ventilation. Reissmann H; Böhm SH; Suárez-Sipmann F; Tusman G; Buschmann C; Maisch S; Pesch T; Thamm O; Plümers C; Schulte am Esch J; Hedenstierna G Intensive Care Med; 2005 Mar; 31(3):431-40. PubMed ID: 15690150 [TBL] [Abstract][Full Text] [Related]
59. Paralysis has no effect on chest wall and respiratory system mechanics of mechanically ventilated, sedated patients. Conti G; Vilardi V; Rocco M; DeBlasi RA; Lappa A; Bufi M; Antonelli M; Gasparetto A Intensive Care Med; 1995 Oct; 21(10):808-12. PubMed ID: 8557868 [TBL] [Abstract][Full Text] [Related]
60. [Intubating laryngeal tube suction disposable: Initial clinical experiences with a novel device for endotracheal intubation]. Bergold MN; Kahle S; Schultzik T; Bücheler M; Byhahn C Anaesthesist; 2016 Jan; 65(1):30-35. PubMed ID: 26481391 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]