273 related articles for article (PubMed ID: 7710152)
1. Relationship between venous and arterial carboxyhemoglobin levels in patients with suspected carbon monoxide poisoning.
Touger M; Gallagher EJ; Tyrell J
Ann Emerg Med; 1995 Apr; 25(4):481-3. PubMed ID: 7710152
[TBL] [Abstract][Full Text] [Related]
2. Relationship between arterial, mixed venous, and internal jugular carboxyhemoglobin concentrations at low, medium, and high concentrations in a piglet model of carbon monoxide toxicity.
Lopez DM; Weingarten-Arams JS; Singer LP; Conway EE
Crit Care Med; 2000 Jun; 28(6):1998-2001. PubMed ID: 10890654
[TBL] [Abstract][Full Text] [Related]
3. Carboxyhemoglobin levels in carbon monoxide poisoning: do they correlate with the clinical picture?
Hampson NB; Hauff NM
Am J Emerg Med; 2008 Jul; 26(6):665-9. PubMed ID: 18606318
[TBL] [Abstract][Full Text] [Related]
4. Pulse oximetry in severe carbon monoxide poisoning.
Hampson NB
Chest; 1998 Oct; 114(4):1036-41. PubMed ID: 9792574
[TBL] [Abstract][Full Text] [Related]
5. Initial blood lactate correlates with carboxyhemoglobin and clinical severity in carbon monoxide poisoned patients.
Cervellin G; Comelli I; Rastelli G; Picanza A; Lippi G
Clin Biochem; 2014 Dec; 47(18):298-301. PubMed ID: 25262985
[TBL] [Abstract][Full Text] [Related]
6. Emergency department management of suspected carbon monoxide poisoning: role of pulse CO-oximetry.
Sebbane M; Claret PG; Mercier G; Lefebvre S; Théry R; Dumont R; Maillé M; Richard JP; Eledjam JJ; de La Coussaye JE
Respir Care; 2013 Oct; 58(10):1614-20. PubMed ID: 23513247
[TBL] [Abstract][Full Text] [Related]
7. The usefulness of the arterial blood gas in pure carbon monoxide poisoning.
Lebby TI; Zalenski R; Hryhorczuk DO; Leikin JB
Vet Hum Toxicol; 1989 Apr; 31(2):138-40. PubMed ID: 2929122
[TBL] [Abstract][Full Text] [Related]
8. Carboxyhemoglobin half-life in carbon monoxide-poisoned patients treated with 100% oxygen at atmospheric pressure.
Weaver LK; Howe S; Hopkins R; Chan KJ
Chest; 2000 Mar; 117(3):801-8. PubMed ID: 10713010
[TBL] [Abstract][Full Text] [Related]
9. The relationship among plasma copeptin, carboxyhemoglobin, and lactate levels in carbon monoxide poisoning.
Ozkan S; Salt O; Durukan P; Sen A; Bulbul E; Duman A; Kavalci C
Hum Exp Toxicol; 2020 Mar; 39(3):311-318. PubMed ID: 31680554
[TBL] [Abstract][Full Text] [Related]
10. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.
Weaver LK; Churchill SK; Deru K; Cooney D
Respir Care; 2013 Feb; 58(2):232-40. PubMed ID: 22782305
[TBL] [Abstract][Full Text] [Related]
11. Predicting of neuropsychosis in carbon monoxide poisoning according to the plasma troponin, COHb, RDW and MPV levels: Neuropsychoses in carbon monoxide poisoning.
Coşkun A; Eren FA; Eren ŞH; Korkmaz İ
Am J Emerg Med; 2019 Jul; 37(7):1254-1259. PubMed ID: 30268441
[TBL] [Abstract][Full Text] [Related]
12. Carbon monoxide poisoning in patients presenting to the emergency department with a headache in winter months.
Zorbalar N; Yesilaras M; Aksay E
Emerg Med J; 2014 Oct; 31(e1):e66-70. PubMed ID: 24128732
[TBL] [Abstract][Full Text] [Related]
13. Determination of carboxyhemoglobin half-life in patients with carbon monoxide toxicity treated with high flow nasal cannula oxygen therapy.
Ozturan IU; Yaka E; Suner S; Ozbek AE; Alyesil C; Dogan NO; Yilmaz S; Pekdemir M
Clin Toxicol (Phila); 2019 Jul; 57(7):617-623. PubMed ID: 30689450
[No Abstract] [Full Text] [Related]
14. The detection of occult CO poisoning through noninvasive measurement of carboxyhemoglobin: A cross-sectional study.
Koyuncu S; Bol O; Ertan T; Günay N; Akdogan Hİ
Am J Emerg Med; 2020 Jun; 38(6):1110-1114. PubMed ID: 31416641
[TBL] [Abstract][Full Text] [Related]
15. COHgb levels predict the long-term development of acute myocardial infarction in CO poisoning.
Kaya H; Coşkun A; Beton O; Zorlu A; Kurt R; Yucel H; Gunes H; Yılmaz MB
Am J Emerg Med; 2016 May; 34(5):840-4. PubMed ID: 26947364
[TBL] [Abstract][Full Text] [Related]
16. Carboxyhemoglobin formation following smoke inhalation injury in sheep is interrelated with pulmonary shunt fraction.
Westphal M; Morita N; Enkhbaatar P; Murakami K; Traber L; Traber DL
Biochem Biophys Res Commun; 2003 Nov; 311(3):754-8. PubMed ID: 14623337
[TBL] [Abstract][Full Text] [Related]
17. The pulse oximetry gap in carbon monoxide intoxication.
Buckley RG; Aks SE; Eshom JL; Rydman R; Schaider J; Shayne P
Ann Emerg Med; 1994 Aug; 24(2):252-5. PubMed ID: 8037391
[TBL] [Abstract][Full Text] [Related]
18. Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia.
Feiner JR; Rollins MD; Sall JW; Eilers H; Au P; Bickler PE
Anesth Analg; 2013 Oct; 117(4):847-858. PubMed ID: 23477959
[TBL] [Abstract][Full Text] [Related]
19. The relationship between blood lactate, carboxy-hemoglobin and clinical status in CO poisoning.
Kaldirim U; Yolcu U; Arziman I; Eyi YE; Tuncer SK
Eur Rev Med Pharmacol Sci; 2014 Oct; 18(19):2777. PubMed ID: 25339468
[TBL] [Abstract][Full Text] [Related]
20. Carbon monoxide poisoning: how many patients do we miss?
Keleş A; Demircan A; Kurtoğlu G
Eur J Emerg Med; 2008 Jun; 15(3):154-7. PubMed ID: 18460956
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]