These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 7717588)

  • 41. The effect of high pressure on microporous membrane oxygenator failure.
    Tamari Y; Tortolani AJ; Maquine M; Lee-Sensiba K; Guarino J
    Artif Organs; 1991 Feb; 15(1):15-22. PubMed ID: 1998486
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effect of cardiogenic oscillations on gas mixing during tracheal insufflation of oxygen.
    Burwen DR; Watson J; Brown R; Josa M; Slutsky AS
    J Appl Physiol (1985); 1986 Mar; 60(3):965-71. PubMed ID: 3957847
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Twenty-four hour left ventricular bypass in the unanesthetized dog: a study employing transthoracic cannulation and a paracorporeal roller pump.
    Pierce WS; Kazama S; Metz H; Prophet GA; Waldhausen JA
    Ann Surg; 1974 Jan; 179(1):39-45. PubMed ID: 4817873
    [No Abstract]   [Full Text] [Related]  

  • 44. Gas transfer in a heparinized membrane oxygenator.
    Rea WJ; Eberle JW; Watson JT; Ecker RR; Sugg WL
    Surg Forum; 1971; 22():188-90. PubMed ID: 5121351
    [No Abstract]   [Full Text] [Related]  

  • 45. Extracorporeal bypass of the right ventricle and pulmonary trunk using autogenous lungs for oxygenation in the dog.
    Cooper RC; Brown BG; Vaden-Pierson M; Garma-Aviña A
    Vet Surg; 1987; 16(2):111-8. PubMed ID: 3148243
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Prolonged pumpless arteriovenous perfusion for carbon dioxide extraction.
    Awad JA; Deslauriers J; Major D; Guojin L; Martin L
    Ann Thorac Surg; 1991 Apr; 51(4):534-40. PubMed ID: 1901479
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Gas exchange efficiency of a membrane oxygenator with use of a vibrating flow pump.
    Naganuma S; Nitta S; Yambe T; Kobayashi S; Tanaka M; Hashimoto H
    Artif Organs; 1995 Jul; 19(7):747-9. PubMed ID: 8572988
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Hemodynamics and gas exchange during prolonged ECMO in dogs (author's transl)].
    Tsuno K; Terasaki H; Nogami T; Yamashiro K; Matsukane I; Kaneko T; Morioka T
    Masui; 1981 Nov; 30(11):1209-15. PubMed ID: 6803006
    [No Abstract]   [Full Text] [Related]  

  • 49. Mechanism of gas absorption from closed cavities in the living body.
    Lanari A; Garegnani TC; de Bercovich CK
    Medicina (B Aires); 1985; 45(2):125-8. PubMed ID: 3939427
    [No Abstract]   [Full Text] [Related]  

  • 50. [Aspects of pathological physiology of the dog in extracorporeal circulation].
    Vanderhoeft P
    Bull Mem Acad R Med Belg; 1994; 149(8-11):321-7; discussion 327-8. PubMed ID: 7550034
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Emergency bypass system: analysis of gas transfer.
    Amsterdam JT; Hedges JR; Engel PJ; Gabel M; Zumwalt R
    Am J Emerg Med; 1987 Jan; 5(1):24-32. PubMed ID: 3814278
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Physiology of Extracorporeal Gas Exchange.
    Bartlett RH
    Compr Physiol; 2020 Jul; 10(3):879-891. PubMed ID: 32941687
    [TBL] [Abstract][Full Text] [Related]  

  • 53. An improved apparatus for blood perfusion of the canine cerebral vasculature.
    Drewes LR
    Neurochem Res; 1980 May; 5(5):551-60. PubMed ID: 6771664
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [A new method for isolated regional perfusion of the liver in vivo. Experimental studies (author's transl)].
    Ghussen F; Nagel K; Isselhard W; Marx G; Wellart A; Müller EW
    Langenbecks Arch Chir; 1982; 356(4):251-7. PubMed ID: 6808267
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Physiological profile during venovenous perfusion in dogs using a polypropylene membrane lung with secondary flows.
    Gardaz JP; Dorrington KL; Py P; Schweizer A
    J Biomed Eng; 1988 Jan; 10(1):74-81. PubMed ID: 3347039
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [Permissible degree of hemodilution without impairment of CO2 excretion; anemia and a-ADCO2].
    Taki K; Ishida M; Mizuma K; Harada K; Mizuno K; Takahashi N; Wakusawa R
    Masui; 1986 May; 35(5):751-4. PubMed ID: 3091877
    [No Abstract]   [Full Text] [Related]  

  • 57. [Effect of a single perfusion with preserved human blood on the gas-exchange and non-gas-exchange functions of an isolated dog heart-lung preparation].
    Priĭmak AA; Rozhkova GG; Kaminskaia GO; Makarova VL; Balta NG
    Patol Fiziol Eksp Ter; 1982; (5):39-42. PubMed ID: 7177713
    [No Abstract]   [Full Text] [Related]  

  • 58. What constitutes adequate perfusion?
    DeWall
    J Cardiovasc Surg (Torino); 1975; 16(5):458-64. PubMed ID: 1194330
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Heparinized vacuum tubes for determination of plasma pH, plasma CO2 content, and blood oxygen saturation with an extensive discussion of pH methodology.
    GAMBINO SR
    Tech Bull Regist Med Technol; 1959 Aug; 29():123-31. PubMed ID: 13826238
    [No Abstract]   [Full Text] [Related]  

  • 60. [Disorders of hemodynamics and respiration in pulmonary emphysema].
    Simbirtsev SA; Beliakov NA; Vasil'ev AA; Sazonov KN; Kobkov VI
    Grud Serdechnososudistaia Khir; 1990; (5):61-3. PubMed ID: 2393601
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.