BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 7723197)

  • 1. A sandwich enzyme immunoassay for cardiac troponin I.
    Suetomi K; Takahama K
    Nihon Hoigaku Zasshi; 1995 Feb; 49(1):26-32. PubMed ID: 7723197
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Medico-legal studies on detection of organ-specific antigens].
    Takahama K
    Nihon Hoigaku Zasshi; 1993 Dec; 47(6):445-55. PubMed ID: 8309099
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of monoclonal antibodies for an assay of cardiac troponin-I and preliminary results in suspected cases of myocardial infarction.
    Bodor GS; Porter S; Landt Y; Ladenson JH
    Clin Chem; 1992 Nov; 38(11):2203-14. PubMed ID: 1424112
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A highly sensitive sandwich enzyme immunoassay for human liver-specific antigen (LSA) and its forensic application.
    Seo Y; Takahama K
    Nihon Hoigaku Zasshi; 1994 Jun; 48(3):150-5. PubMed ID: 8065064
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasensitive and more specific enzyme immunoassay (immune complex transfer enzyme immunoassay) for p24 antigen of HIV-1 in serum using affinity-purified rabbit anti-p24 Fab' and monoclonal mouse anti-p24 Fab'.
    Hashida S; Hashinaka K; Nishikata I; Saito A; Takamizawa A; Shinagawa H; Ishikawa E
    J Clin Lab Anal; 1996; 10(5):302-7. PubMed ID: 8887010
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analytical performance and clinical utility of a sensitive immunoassay for determination of human cardiac troponin I.
    Davies E; Gawad Y; Takahashi M; Shi Q; Lam P; Styba G; Lau A; Heeschen C; Usategui M; Jackowski G
    Clin Biochem; 1997 Aug; 30(6):479-90. PubMed ID: 9316743
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A highly sensitive and specific sandwich enzyme immunoassay for water soluble A and B substances.
    Yukawa N; Kohno T; Ishikawa E; Takahama K
    Nihon Hoigaku Zasshi; 1989 Feb; 43(1):20-6. PubMed ID: 2671453
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Serum levels of cardiac troponin I and other marker proteins in patients with chronic renal failure.
    Nakai K; Nakai K; Nagane Y; Obara W; Sato M; Ohi K; Matsumoto N; Takanashi N; Itoh C
    Clin Exp Nephrol; 2004 Mar; 8(1):43-7. PubMed ID: 15067515
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of cardiac troponin I in striated muscle using three experimental methods.
    Fredericks S; Bainbridge K; Murray JF; Collinson PO; Carter ND; Holt DW
    Ann Clin Biochem; 2003 May; 40(Pt 3):244-8. PubMed ID: 12803836
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Protein array for assist diagnosis of acute myocardial infarction.
    Guo H; Zhang J; Yang D; Xiao P; He N
    Colloids Surf B Biointerfaces; 2005 Feb; 40(3-4):195-8. PubMed ID: 15708513
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac troponin I is a sensitive, specific biomarker of cardiac injury in laboratory animals.
    O'Brien PJ; Smith DE; Knechtel TJ; Marchak MA; Pruimboom-Brees I; Brees DJ; Spratt DP; Archer FJ; Butler P; Potter AN; Provost JP; Richard J; Snyder PA; Reagan WJ
    Lab Anim; 2006 Apr; 40(2):153-71. PubMed ID: 16600075
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Cardiac troponin I: a marker for detecting non-ischemic cardiac injury].
    Zeng L; Chen Y; Wu M
    Zhonghua Yi Xue Za Zhi; 2001 Apr; 81(7):393-5. PubMed ID: 11798903
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac findings in asymptomatic chronic hemodialysis patients with persistently elevated cardiac troponin I levels.
    Katerinis I; Nguyen QV; Magnin JL; Descombes E
    Ren Fail; 2008; 30(4):357-62. PubMed ID: 18569907
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of myoglobin, creatine kinase-MB, and cardiac troponin I for diagnosis of acute myocardial infarction.
    Wu AH; Feng YJ; Contois JH; Pervaiz S
    Ann Clin Lab Sci; 1996; 26(4):291-300. PubMed ID: 8800429
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of anti-ovalbumin IgG in serum by immune complex transfer enzyme immunoassay.
    Hirota K; Kamashima T; Totani M
    Clin Lab; 2001; 47(5-6):213-7. PubMed ID: 11405598
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Utilization of recombinant Fab fragments in a cTnI immunoassay conducted in spot wells.
    Ylikotila J; Hellström JL; Eriksson S; Vehniäinen M; Välimaa L; Takalo H; Bereznikova A; Pettersson K
    Clin Biochem; 2006 Aug; 39(8):843-50. PubMed ID: 16806144
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monoclonal Antibodies Against Human Cardiac Troponin I for Immunoassays II.
    Lee G; Liu S
    Monoclon Antib Immunodiagn Immunother; 2015 Jun; 34(3):169-73. PubMed ID: 26090594
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An improved preparation of antibody-coated polystyrene beads for sandwich enzyme immunoassay.
    Ishikawa E; Hamaguchi Y; Imagawa M; Inada M; Imura H; Nakazawa N; Ogawa H
    J Immunoassay; 1980; 1(3):385-98. PubMed ID: 7014640
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Upconverting nanophosphors as reporters in a highly sensitive heterogeneous immunoassay for cardiac troponin I.
    Sirkka N; Lyytikäinen A; Savukoski T; Soukka T
    Anal Chim Acta; 2016 Jun; 925():82-7. PubMed ID: 27188320
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabrication of anionic sulfate-functionalized nanoparticles as an immunosensor by protein immobilization.
    Kim S; Pyo HB; Ko SH; Ah CS; Kim A; Kim WJ
    Langmuir; 2010 May; 26(10):7355-64. PubMed ID: 20205399
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.