These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 7731887)

  • 1. P wave oversensing in a unipolar VVI pacemaker.
    van Gelder BM; Bracke FA; El Gamal MI
    Pacing Clin Electrophysiol; 1995 Feb; 18(2):370-3. PubMed ID: 7731887
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Suppression of ventricular output by noise in the atrial channel in a dual chamber pacemaker.
    Ben-Zur UM; Kahn S; Gross JN; Platt SB; Goodfriend MA; Furman S
    Pacing Clin Electrophysiol; 1995 Aug; 18(8):1586-8. PubMed ID: 7479181
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ventricular capture by anodal pacemaker stimulation.
    Occhetta E; Bortnik M; Marino P
    Europace; 2006 May; 8(5):385-7. PubMed ID: 16636000
    [TBL] [Abstract][Full Text] [Related]  

  • 4. False inhibition of an atrial demand pacemaker caused by an insulation defect in a polyurethane lead.
    van Gelder LM; El Gamal MI
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):834-9. PubMed ID: 6195601
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pacemaker inhibition due to anodal ring electrode contact.
    Henderson D; Maher M; Johnson D
    Pacing Clin Electrophysiol; 1995 Dec; 18(12 Pt 1):2222-4. PubMed ID: 8771137
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Severe syncope due to the application of a pacemaker telemetry wand.
    Preumont N; De Canniere D; Baroud I; Stoupel E
    Acta Cardiol; 1996; 51(6):541-3. PubMed ID: 9124024
    [TBL] [Abstract][Full Text] [Related]  

  • 7. P-wave sensing in VVI pacemakers: useful or a problem?
    van Gelder LM; el Gamal MI; Tielen CH
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1413-8. PubMed ID: 2462217
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Benefits of intracardiac electrograms and programmable sensing polarity in preventing pacemaker inhibition due to spurious screw-in lead signals.
    Nalos PC; Nyitray W
    Pacing Clin Electrophysiol; 1990 Sep; 13(9):1101-4. PubMed ID: 1700383
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Atrial lead dislodgement with a DDD pacemaker.
    Greenspon AJ; Cox J; Greenberg RM
    Pacing Clin Electrophysiol; 1986 May; 9(3):436-40. PubMed ID: 2423986
    [TBL] [Abstract][Full Text] [Related]  

  • 10. QT dependent T wave sensing.
    Böhm A; Pintér A; Préda I
    Pacing Clin Electrophysiol; 1998 Jul; 21(7):1490-1. PubMed ID: 9670199
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Self-inhibition of an AV sequential demand (DVI) pulse generator due to polyurethane lead insulation disruption.
    Sanford CF
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):840-4. PubMed ID: 6195602
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined epicardial and transvenous pacing in an infant with operated complex congenital heart disease and permanent epicardial DDD pacemaker as treatment of dysfunction of the epicardial ventricular lead.
    Loukopoulou SN; Eleftherakis NG; Kourtesis AN; Thanopoulos BD
    Hellenic J Cardiol; 2009; 50(1):68-72. PubMed ID: 19196624
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous Holter telemetry of atrial electrograms and marker annotations using a common Holter recording system: impact on Holter electrocardiogram interpretation in patients with dual chamber pacemakers.
    Wiegand UK; Bonnemeier H; Bode F; Eberhardt F; Chun JK; Katus HA; Peters W
    Pacing Clin Electrophysiol; 2002 Dec; 25(12):1724-30. PubMed ID: 12520673
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Unusual VDD-pacing.
    Schumann J; Kiencke S; Osswald S; Rickenbacher P
    Europace; 2007 Jan; 9(1):76-7. PubMed ID: 17224431
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Positional convulsant syncope in a pacemaker patient following insulation break of the right ventricular lead.
    Ben Lassoued M; Baatour M; Haggui A; Lamine K
    BMJ Case Rep; 2014 May; 2014():. PubMed ID: 24827652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Oversensing from electrode 'chatter' in a bipolar pacing lead: a case report.
    Chew PH; Brinker JA
    Pacing Clin Electrophysiol; 1990 Jun; 13(6):808-11. PubMed ID: 1695361
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Pacemaker ECG Quiz No. 23: Pacemaker malfunction or arrhythmia?].
    Israel CW
    Herzschrittmacherther Elektrophysiol; 2010 Sep; 21(3):200-3. PubMed ID: 20803024
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Should unipolar leads be implanted in the atrium? A Holter electrocardiographic comparison of threshold adapted unipolar and high sensitive bipolar sensing.
    Wiegand UK; Schier H; Bode F; Brandes A; Potratz J
    Pacing Clin Electrophysiol; 1998 Aug; 21(8):1601-8. PubMed ID: 9725160
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial experience with 1.5-mm2 high impedance, steroid-eluting pacing electrodes.
    Fogel R; Pirzada F; Casavant D; Boone J; Bowman A; Steinhaus D; Gilbert M; Vlietstra R; Belott P; Parsonnet V; Tilton G; White M
    Pacing Clin Electrophysiol; 1996 Feb; 19(2):188-96. PubMed ID: 8834688
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dizziness spells: Should one suspect the pacemaker?
    Elsheshtawy M; Yang F; Prabhu S
    Am J Emerg Med; 2019 Mar; 37(3):563.e1-563.e3. PubMed ID: 30581029
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.