  • 1. [Distribution of a hypoxic gas mixture by retro-pollution of a medical gas distribution system].
    Gorce P; Crisan A; Gondret R; Viallard ML; Clergue F
    Ann Fr Anesth Reanim; 1994; 13(5):741-4. PubMed ID: 7733527
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Defective gas mixers, a cause of retro-pollution of medical gas distribution pipelines].
    Otteni JC; Ancellin J; Cazalaà JB
    Ann Fr Anesth Reanim; 1997; 16(1):68-72. PubMed ID: 9686101
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Pollution and retro-pollution by the distribution system of medical gases].
    Otteni JC; Ancellin J; Cazalaà JB; Clergue F
    Ann Fr Anesth Reanim; 1994; 13(5):713-25. PubMed ID: 7733522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hypoxia due to air in the oxygen pipeline. A case for oxygen monitoring in theatre.
    Thorp JM; Railton R
    Anaesthesia; 1982 Jun; 37(6):683-7. PubMed ID: 7091626
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Hypoxia secondary to the failure of an oxygen-air-nitrous oxide mixer].
    Michon-Boyer-Chammard F; Fischler M; Douau PY; Vourc'h G
    Ann Fr Anesth Reanim; 1988; 7(2):165-7. PubMed ID: 3163240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Delivery of an hypoxic gas mixture due to a defective rubber seal of a flowmeter control tube.
    Hay H
    Eur J Anaesthesiol; 2000 Jul; 17(7):456-8. PubMed ID: 10964148
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simplified concept for controlling oxygen mixtures in the anaesthetic machine--better, cheaper and more user-friendly?
    Berge JA; Gramstad L; Grimnes S
    Acta Anaesthesiol Scand; 1995 May; 39(4):563-7. PubMed ID: 7676800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Failure of the central oxygen supply to a surgical area. Analysis of a critical incident].
    Herrera A; Bueno F
    Rev Esp Anestesiol Reanim; 1995 Mar; 42(3):96-9. PubMed ID: 7777689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Pressure control in medical gas distribution systems].
    Bourgain JL; Benayoun L; Baguenard P; Haré G; Puizillout JM; Billard V
    Ann Fr Anesth Reanim; 1997; 16(8):940-4. PubMed ID: 9750641
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of an active inspired hypoxic guard.
    Ghijselings IE; De Cooman S; Carette R; Peyton PJ; De Wolf AM; Hendrickx JF
    J Clin Monit Comput; 2016 Feb; 30(1):63-8. PubMed ID: 25757405
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Air contamination of a closed anesthesia circuit.
    Mizuno K; Sumiyoshi R
    Acta Anaesthesiol Scand; 1998 Jan; 42(1):128-30. PubMed ID: 9527735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hypoxic gas mixture with Quantiflex Monitored Dial Mixer and induction room safety.
    Wishaw K
    Anaesth Intensive Care; 1991 Feb; 19(1):127. PubMed ID: 2012274
    [No Abstract]   [Full Text] [Related]  

  • 13. Oxygen delivery failure resulting from interference with a Bain breathing system.
    Hay H
    Eur J Anaesthesiol; 2000 Sep; 17(9):591-3. PubMed ID: 11029128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Respiratory and anesthetic gas flow monitoring].
    Günther H; Helbig P; Völker HU
    Anaesthesiol Reanim; 1987; 12(4):213-8. PubMed ID: 3477234
    [No Abstract]   [Full Text] [Related]  

  • 15. Oxygen contamination of the nitrous oxide pipeline supply.
    Lye A; Patrick R
    Anaesth Intensive Care; 1998 Apr; 26(2):207-9. PubMed ID: 9564404
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Oxygen duct pollution by nitrous oxide. A defective flowmeter].
    Stieglitz P; Girardet P; Pomet D; Roussel C; Vincent F
    Ann Fr Anesth Reanim; 1982; 1(5):555-6. PubMed ID: 6223545
    [No Abstract]   [Full Text] [Related]  

  • 17. A modification of the Bain system for ambient air-oxygen inhalation.
    Shrestha BM; Tweed WA; Basnyat NB; Lekhak BD
    Anaesthesia; 1994 Aug; 49(8):703-6. PubMed ID: 7943703
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Failure of a new system to prevent delivery of hypoxic gas mixture.
    Malone BT
    Anesthesiology; 1981 May; 54(5):436-7. PubMed ID: 7224223
    [No Abstract]   [Full Text] [Related]  

  • 19. A computer-controlled anaesthetic gas mixer.
    Boaden RW; Hutton P; Monk C
    Anaesthesia; 1989 Aug; 44(8):665-9. PubMed ID: 2528924
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Australian Incident Monitoring Study. The oxygen analyser: applications and limitations--an analysis of 200 incident reports.
    Barker L; Webb RK; Runciman WB; Van der Walt JH
    Anaesth Intensive Care; 1993 Oct; 21(5):570-4. PubMed ID: 8273877
    [TBL] [Abstract][Full Text] [Related]  