These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 7739092)

  • 1. [Measurements of ventilatory parameters during closed circuit anesthesia--comparisons with semiclosed circuit, high-flow anesthesia].
    Morita S; Saito H; Hayashi T; Goto T; Niimi Y
    Masui; 1995 Feb; 44(2):210-5. PubMed ID: 7739092
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Closed-circuit anesthesia preserves skin blood flow during surgery.
    Ke YC; Ho ST; Yi HD; Li CY; Wang JJ; Lin CY; Lu CC
    Acta Anaesthesiol Taiwan; 2006 Mar; 44(1):25-30. PubMed ID: 16623404
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The effects of fresh gas flow rate on the work of breathing during semi-closed circuit anesthesia].
    Yamada T; Kakoi H; Hirokawa T; Koyama K; Miyao H; Kawasaki J; Kawazoe T
    Masui; 1994 Jan; 43(1):55-8. PubMed ID: 8309055
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
    Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
    Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Increased resistance of hygroscopic condenser humidifiers when using a closed circuit suction system.
    Martinez FJ; Pietchel S; Wise C; Walek J; Beamis JF
    Crit Care Med; 1994 Oct; 22(10):1668-73. PubMed ID: 7924380
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The effect of fresh gas flow on the minute volume of anesthesia ventilators with a gas reservoir].
    Latorre F; Jantzen JP
    Anaesthesist; 1990 Jul; 39(7):382-3. PubMed ID: 2386308
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Fresh gas flow and artificial respiration in anesthesia. Technical requirements for the adequate use of rebreathing systems].
    Baum J; Sachs G
    Anasth Intensivther Notfallmed; 1990 Feb; 25(1):72-8. PubMed ID: 2309993
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A clinical determination of optimal fresh gas flow in a baby EAR circuit.
    Theerapongpakdee S; Phanpanusit T; Horatanaruang D; Bunsangjaroen P; Limpkulwathanaporn P; Thananun M; Nonlhaopol D
    J Med Assoc Thai; 2009 May; 92(5):667-71. PubMed ID: 19459529
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical applications of low flow and closed circuit anesthesia.
    Baum J
    Acta Anaesthesiol Belg; 1990; 41(3):239-47. PubMed ID: 2260429
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of flow rate on breathing circuit compliance and tidal volume delivered to patients in mechanical ventilation.
    Silvestri S
    Physiol Meas; 2006 Jan; 27(1):23-33. PubMed ID: 16365508
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Minimal-flow xenon and semiclosed circuit anesthesia for computed tomographic measurement of local cerebral blood flow (LCBF)].
    Oku S; Karasawa J; Kuriyama Y; Satou K; Yahagi N; Okumura F; Kikuchi H; Sawada T; Sakashita Z; Naitou H
    No To Shinkei; 1984 Aug; 36(8):813-9. PubMed ID: 6498027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of continuous, expiratory, reverse, and bi-directional tracheal gas insufflation in conjunction with a flow relief valve on delivered tidal volume, total positive end-expiratory pressure, and carbon dioxide elimination: a bench study.
    Delgado E; Hete B; Hoffman LA; Tasota FJ; Pinsky MR
    Respir Care; 2001 Jun; 46(6):577-85. PubMed ID: 11353546
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Desflurane consumption with the Zeus during automated closed circuit versus low flow anesthesia.
    De Cooman S; Lecain A; Sosnowski M; De Wolf AM; Hendrickx JF
    Acta Anaesthesiol Belg; 2009; 60(1):35-7. PubMed ID: 19459552
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Minimal flow anesthesia in newborn infants--advantages and risks].
    Gebhardt R; Weiser UK
    Anaesthesiol Reanim; 1999; 24(2):41-6. PubMed ID: 10372434
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ventilatory adequacy and respiratory mechanics with laryngeal mask versus tracheal intubation during positive pressure ventilation.
    Fassoulaki A; Paraskeva A; Karabinis G; Melemeni A
    Acta Anaesthesiol Belg; 1999; 50(3):113-7. PubMed ID: 10529848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory diagnostic possibilities during closed circuit anesthesia.
    Verkaaik AP; Erdmann W
    Acta Anaesthesiol Belg; 1990; 41(3):177-88. PubMed ID: 2260424
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Compression volume in adult ventilator circuits: a comparison of five disposable circuits and a nondisposable circuit.
    Hess D; McCurdy S; Simmons M
    Respir Care; 1991 Oct; 36(10):1113-8. PubMed ID: 10145567
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.