These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 7741261)

  • 1. Determination of cadmium in whole blood and urine electrothermal atomic absorption spectrometry using palladium-based modifiers and in situ decontamination.
    Moreira Mde F; Curtius AJ; de Campos RC
    Analyst; 1995 Mar; 120(3):947-50. PubMed ID: 7741261
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multielement determination of cadmium and lead in urine by simultaneous electrothermal atomic absorption spectrometry with an end-capped graphite tube.
    Correia PR; Nomura CS; Oliveira PV
    Anal Sci; 2003 Nov; 19(11):1519-23. PubMed ID: 14640451
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: comparative study of different chemical modifiers.
    Vilar Fariñas M; Barciela García J; García Martín S; Peña Crecente R; Herrero Latorre C
    Anal Chim Acta; 2007 May; 591(2):231-8. PubMed ID: 17481414
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of direct solid sampling and slurry sampling for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry.
    Araujo RG; Oleszczuk N; Rampazzo RT; Costa PA; Silva MM; Vale MG; Welz B; Ferreira SL
    Talanta; 2008 Oct; 77(1):400-6. PubMed ID: 18804652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct determination of selenium in urine samples by electrothermal atomic absorption spectrometry using a Zr plus Rh-treated graphite tube and co-injection of Rh as chemical modifier.
    Pinto FG; Andrada D; Magalhães CG; Nunes BR; de Amorim FR; Franco MB; Saint'pierre TD; da Silva JB; Curtius AJ
    Anal Bioanal Chem; 2005 Nov; 383(5):825-32. PubMed ID: 16189678
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effectiveness of palladium matrix modification for the determination of thallium by graphite furnace atomic absorption spectrometry.
    Yang Q; Smeyers-Verbeke J
    Clin Chim Acta; 1991 Dec; 204(1-3):23-35. PubMed ID: 1819466
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimization and validation of a procedure for the determination of total chromium in postmortem material by ETAAS.
    Lech T; Dudek-Adamska D
    J Anal Toxicol; 2013 Mar; 37(2):97-101. PubMed ID: 23316027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct determination of Cr and Cu in urine samples by electrothermal atomic absorption spectrometry using ruthenium as permanent modifier (R1).
    Lelis KL; Magalhães CG; Rocha CA; of Silva JB
    Anal Bioanal Chem; 2002 Dec; 374(7-8):1301-5. PubMed ID: 12474101
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Chromium determination in pharmaceutical grade barium sulfate by solid sampling electrothermal atomic absorption spectrometry with Zeeman-effect background correction.
    Bolzan RC; Rodrigues LF; Mattos JC; Dressler VL; Flores EM
    Talanta; 2007 Nov; 74(1):119-24. PubMed ID: 18371620
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of beryllium and selenium in human urine and of selenium in human serum by graphite-furnace atomic absorption spectrophotometry.
    Wang HC; Peng HW; Kuo MS
    Anal Sci; 2001 Apr; 17(4):527-32. PubMed ID: 11990571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of toxic elements in plastics from waste electrical and electronic equipment by slurry sampling electrothermal atomic absorption spectrometry.
    Santos MC; Nóbrega JA; Baccan N; Cadore S
    Talanta; 2010 Jun; 81(4-5):1781-7. PubMed ID: 20441973
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elimination of matrix and spectral interferences in the measurement of lead and cadmium in urine and blood by electrothermal atomic absorption spectrometry with deuterium background correction.
    D'Haese PC; Lamberts LV; Liang L; Van de Vyver FL; De Broe ME
    Clin Chem; 1991 Sep; 37(9):1583-8. PubMed ID: 1893594
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrophotometry for the determination of trace elements in blood and urine from non occupationally exposed populations.
    White MA
    J Trace Elem Med Biol; 1999 Jul; 13(1-2):93-101. PubMed ID: 10445225
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of chemical modifiers for direct determination of Cd, Cu and Zn in food stuffs by solid-sampling-ETAAS.
    Török P; Žemberyová M
    Food Chem; 2012 May; 132(1):554-60. PubMed ID: 26434331
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of manganese in urine and whole blood samples by electrothermal atomic absorption spectrometry: comparison of chemical modifiers.
    Pinto FG; Rey UV; Fernandes EF; Silveira JN; Amorim L; da Silva JB
    Anal Sci; 2006 Dec; 22(12):1605-9. PubMed ID: 17159325
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multielement electrothermal atomic absorption spectrometry: a study on direct and simultaneous determination of chromium and manganese in urine.
    Oliveira PV; Oliveira E
    Fresenius J Anal Chem; 2001 Dec; 371(7):909-14. PubMed ID: 11769799
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry.
    da Silva AF; Borges DL; Lepri FG; Welz B; Curtius AJ; Heitmann U
    Anal Bioanal Chem; 2005 Aug; 382(8):1835-41. PubMed ID: 15965684
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Nickel as a chemical modifier for sensitivity enhancement and fast atomization processes in electrothermal atomic absorption spectrometric determination of cadmium in biological and environmental samples.
    Feo JC; Castro MA; Lumbreras JM; de Celis B; Aller AJ
    Anal Sci; 2003 Dec; 19(12):1631-6. PubMed ID: 14696927
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The determination of total Se in urine and serum by graphite furnace atomic absorption spectrometry using Ir as permanent modifier and in situ oxidation for complete trimethylselenonium recovery.
    Grinberg P; Gonçalves RA; de Campos RC
    Anal Bioanal Chem; 2005 Dec; 383(7-8):1044-51. PubMed ID: 16267645
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimization and Validation of an ETAAS Method for the Determination of Nickel in Postmortem Material.
    Dudek-Adamska D; Lech T; Kościelniak P
    J Anal Toxicol; 2015; 39(6):460-4. PubMed ID: 25868556
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.