These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 7744891)

  • 1. External fixation and limited internal fixation for complex fractures of the tibial plateau.
    Marsh JL; Smith ST; Do TT
    J Bone Joint Surg Am; 1995 May; 77(5):661-73. PubMed ID: 7744891
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-energy fractures of the tibial plateau. Knee function after longer follow-up.
    Weigel DP; Marsh JL
    J Bone Joint Surg Am; 2002 Sep; 84(9):1541-51. PubMed ID: 12208910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial.
    Canadian Orthopaedic Trauma Society
    J Bone Joint Surg Am; 2006 Dec; 88(12):2613-23. PubMed ID: 17142411
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Surgical technique.
    Hall JA; Beuerlein MJ; McKee MD;
    J Bone Joint Surg Am; 2009 Mar; 91 Suppl 2 Pt 1():74-88. PubMed ID: 19255201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Supracondylar fractures of the femur treated by external fixation.
    Marsh JL; Jansen H; Yoong HK; Found EM
    J Orthop Trauma; 1997 Aug; 11(6):405-10; discussion 411. PubMed ID: 9314146
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Infection after spanning external fixation for high-energy tibial plateau fractures: is pin site-plate overlap a problem?
    Laible C; Earl-Royal E; Davidovitch R; Walsh M; Egol KA
    J Orthop Trauma; 2012 Feb; 26(2):92-7. PubMed ID: 22011631
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bicondylar tibial plateau fractures treated with a hybrid ring external fixator: a preliminary study.
    Stamer DT; Schenk R; Staggers B; Aurori K; Aurori B; Behrens FF
    J Orthop Trauma; 1994 Dec; 8(6):455-61. PubMed ID: 7869158
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcome of open comminuted tibial plateau fractures treated using an external fixator.
    Subasi M; Kapukaya A; Arslan H; Ozkul E; Cebesoy O
    J Orthop Sci; 2007 Jul; 12(4):347-53. PubMed ID: 17657554
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of an articulated external fixator for fractures of the tibial plafond.
    Marsh JL; Bonar S; Nepola JV; Decoster TA; Hurwitz SR
    J Bone Joint Surg Am; 1995 Oct; 77(10):1498-509. PubMed ID: 7593058
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparative study on internal fixation and external fixation for the treatment of complex tibial plateau fracture].
    Zhuo N; Li Z; Ge J; Lu X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Aug; 22(8):952-5. PubMed ID: 18773812
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Treatment of complex (Schatzker Type VI) fractures of the tibial plateau with circular wire external fixation: retrospective case review.
    Kumar A; Whittle AP
    J Orthop Trauma; 2000; 14(5):339-44. PubMed ID: 10926241
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Operative treatment of fractures of the tibial plafond. A randomized, prospective study.
    Wyrsch B; McFerran MA; McAndrew M; Limbird TJ; Harper MC; Johnson KD; Schwartz HS
    J Bone Joint Surg Am; 1996 Nov; 78(11):1646-57. PubMed ID: 8934478
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.
    Kim JW; Oh CW; Oh JK; Kyung HS; Park KH; Kim HJ; Jung JW; Jung YS
    Injury; 2017 Jun; 48(6):1190-1193. PubMed ID: 28320508
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of trans-articular and extra-articular external fixation for management of distal tibial intra-articular fractures.
    El-Shazly M; Dalby-Ball J; Burton M; Saleh M
    Injury; 2001 Dec; 32 Suppl 4():SD99-106. PubMed ID: 11812483
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Updated Three-Column Concept in surgical treatment for tibial plateau fractures - A prospective cohort study of 287 patients.
    Wang Y; Luo C; Zhu Y; Zhai Q; Zhan Y; Qiu W; Xu Y
    Injury; 2016 Jul; 47(7):1488-96. PubMed ID: 27211226
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preoperative Plan with 3D Printing in Internal and External Fixation for Complex Tibial Plateau Fractures.
    Wu WY; Xu WG; Wan CY; Fang M
    Orthop Surg; 2019 Aug; 11(4):560-568. PubMed ID: 31456325
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment of tibial plateau fractures by limited internal fixation.
    Duwelius PJ; Rangitsch MR; Colville MR; Woll TS
    Clin Orthop Relat Res; 1997 Jun; (339):47-57. PubMed ID: 9186200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High energy tibial plateau fractures treated with hybrid external fixation.
    Babis GC; Evangelopoulos DS; Kontovazenitis P; Nikolopoulos K; Soucacos PN
    J Orthop Surg Res; 2011 Jul; 6():35. PubMed ID: 21756337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau: a minimum five-year follow-up study.
    Saleh KJ; Sherman P; Katkin P; Windsor R; Haas S; Laskin R; Sculco T
    J Bone Joint Surg Am; 2001 Aug; 83(8):1144-8. PubMed ID: 11507121
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does Early versus Delayed Spanning External Fixation Impact Complication Rates for High-energy Tibial Plateau and Plafond Fractures?
    Haller JM; Holt D; Rothberg DL; Kubiak EN; Higgins TF
    Clin Orthop Relat Res; 2016 Jun; 474(6):1436-44. PubMed ID: 26481122
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.