106 related articles for article (PubMed ID: 7749086)
1. [Turbo-spin-echo (TSE) sequences with selective fat suppression (SPIR) compared with chemical shift sequences in MRI for differentiation of adrenal tumors. Spectral Presaturation by Inversion Recovery].
Kreft B; Sommer T; Vahlensieck M; Seewald S; Vetter H; Schild H
Rofo; 1995 Apr; 162(4):311-8. PubMed ID: 7749086
[TBL] [Abstract][Full Text] [Related]
2. [Comparison of three-dimensional gradient echo, turbo spin echo and steady-state gradient echo sequences in axial MRI examination of the cervical spine].
Mahmutyazicioğlu K; Ozdemir H; Savranlar A; Ozer T; Erdem O; Erdem Z; Gündoğdu S
Tani Girisim Radyol; 2003 Dec; 9(4):432-8. PubMed ID: 14730951
[TBL] [Abstract][Full Text] [Related]
3. [Turbo-spin-echo sequences with selective fat suppression (SPIR) in the MRI of focal liver lesions at 0.5 tesla].
Kreft B; Layer G; Kuhl C; Sommer T; Gieseke J; Schild H
Rofo; 1995 Nov; 163(5):411-6. PubMed ID: 8527755
[TBL] [Abstract][Full Text] [Related]
4. Diagnostic accuracy of chemical-shift MR imaging to differentiate between adrenal adenomas and non adenoma adrenal lesions.
Maurea S; Imbriaco M; D'Angelillo M; Mollica C; Camera L; Salvatore M
Radiol Med; 2006 Aug; 111(5):674-86. PubMed ID: 16791464
[TBL] [Abstract][Full Text] [Related]
5. Dynamic contrast enhanced MRI in the differential diagnosis of adrenal adenomas and malignant adrenal masses.
Inan N; Arslan A; Akansel G; Anik Y; Balci NC; Demirci A
Eur J Radiol; 2008 Jan; 65(1):154-62. PubMed ID: 17466481
[TBL] [Abstract][Full Text] [Related]
6. [The differentiation of adrenal gland tumors: an improvement in accuracy by a combination of fat-sensitive, T2-weighted and contrast-enhanced MR sequences].
Zimmermann GG; Debatin JF; Krestin GP
Rofo; 1997 Aug; 167(2):153-9. PubMed ID: 9333356
[TBL] [Abstract][Full Text] [Related]
7. Adrenal masses in patients with malignancy: prospective comparison of echo-planar, fast spin-echo, and chemical shift MR imaging.
Schwartz LH; Panicek DM; Koutcher JA; Brown KT; Getrajdman GI; Heelan RT; Burt M
Radiology; 1995 Nov; 197(2):421-5. PubMed ID: 7480686
[TBL] [Abstract][Full Text] [Related]
8. In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissue using thin-slice echo-planar imaging.
Manenti G; Squillaci E; Di Roma M; Carlani M; Mancino S; Simonetti G
Radiol Med; 2006 Dec; 111(8):1124-33. PubMed ID: 17171522
[TBL] [Abstract][Full Text] [Related]
9. [Comparison of magnetic resonance Spin-echo sequences and fat-suppressed sequences in bone diseases].
Pozzi Mucelli R; Cova M; Shariat-Razavi I; Zucconi F; Ukmar M; Longo R
Radiol Med; 1997 May; 93(5):504-9. PubMed ID: 9280929
[TBL] [Abstract][Full Text] [Related]
10. [Evaluation of rapid gradient-echo and turbo-spin-echo sequences in MRT of focal liver lesions using 0.5 tesla].
Kreft B; Layer G; Spiller L; Träber F; Wolff M; Gieseke J; Steudel A
Rofo; 1994 Dec; 161(6):512-8. PubMed ID: 7803774
[TBL] [Abstract][Full Text] [Related]
11. Magnetic resonance imaging of the adrenal gland.
Boland GW; Lee MJ
Crit Rev Diagn Imaging; 1995; 36(2):115-74. PubMed ID: 7612177
[TBL] [Abstract][Full Text] [Related]
12. MR imaging of adrenal masses: value of chemical-shift imaging for distinguishing adenomas from other tumors.
Bilbey JH; McLoughlin RF; Kurkjian PS; Wilkins GE; Chan NH; Schmidt N; Singer J
AJR Am J Roentgenol; 1995 Mar; 164(3):637-42. PubMed ID: 7863885
[TBL] [Abstract][Full Text] [Related]
13. [Study of comparing the multiple MR sequenc in the articular cartilage of knee joint].
Gu F; Zhang XZ
Zhonghua Yi Xue Za Zhi; 2008 Jan; 88(4):245-9. PubMed ID: 18361835
[TBL] [Abstract][Full Text] [Related]
14. Hepatic malignant tumour versus cavernous haemangioma: differentiation on multiple breath-hold turbo spin-echo MRI sequences with different T2-weighting and T2-relaxation time measurements on a single slice multi-echo sequence.
Chan YL; Lee SF; Yu SC; Lai P; Ching AS
Clin Radiol; 2002 Apr; 57(4):250-7. PubMed ID: 12014868
[TBL] [Abstract][Full Text] [Related]
15. Adrenal masses: quantification of fat content with double-echo chemical shift in-phase and opposed-phase FLASH MR images for differentiation of adrenal adenomas.
Namimoto T; Yamashita Y; Mitsuzaki K; Nakayama Y; Makita O; Kadota M; Takahashi M
Radiology; 2001 Mar; 218(3):642-6. PubMed ID: 11230633
[TBL] [Abstract][Full Text] [Related]
16. [Comparison of fast turbo-spin-echo and gradient- and spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla].
Jung G; Krahe T; Kugel H; Gieseke J; Walter C; Fischbach R; Landwehr P
Rofo; 1996 Aug; 165(2):137-43. PubMed ID: 8924665
[TBL] [Abstract][Full Text] [Related]
17. Value of chemical shift subtraction MRI in characterization of adrenal masses.
Savci G; Yazici Z; Sahin N; Akgöz S; Tuncel E
AJR Am J Roentgenol; 2006 Jan; 186(1):130-5. PubMed ID: 16357391
[TBL] [Abstract][Full Text] [Related]
18. Fat suppression with short inversion time inversion-recovery and chemical-shift selective saturation: a dual STIR-CHESS combination prepulse for turbo spin echo pulse sequences.
Tanabe K; Nishikawa K; Sano T; Sakai O; Jara H
J Magn Reson Imaging; 2010 May; 31(5):1277-81. PubMed ID: 20432368
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of patellar chondromalacia with MR: comparison between T2-weighted FSE SPIR and GE MTC.
Macarini L; Perrone A; Murrone M; Marini S; Stefanelli M
Radiol Med; 2004 Sep; 108(3):159-71. PubMed ID: 15343130
[TBL] [Abstract][Full Text] [Related]
20. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.
Hussain SM; De Becker J; Hop WC; Dwarkasing S; Wielopolski PA
J Magn Reson Imaging; 2005 Mar; 21(3):219-29. PubMed ID: 15723376
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]