BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 775003)

  • 1. Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization. Fick vs. dye cardiac outputs.
    Reddy PS; Curtiss EI; Bell B; O'Toole JD; Salerni R; Leon DF; Shaver JA
    J Lab Clin Med; 1976 Apr; 87(4):568-76. PubMed ID: 775003
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Fick and dye cardiac outputs during rest and exercise in 1,022 patients.
    Nanas JN; Anastasiou-Nana MI; Sutton RB; Menlove RL; Tsagaris TJ
    Can J Cardiol; 1986; 2(4):195-9. PubMed ID: 3768778
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monitoring of cardiac output by thermodilution after open-heart surgery.
    Kohanna FH; Cunningham JN
    J Thorac Cardiovasc Surg; 1977 Mar; 73(3):451-7. PubMed ID: 320399
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of cardiac output by carbon dioxide rebreathing.
    Wigle RD; Hamilton PD; Parker JO
    Can J Appl Sport Sci; 1979 Jun; 4(2):135-9. PubMed ID: 391433
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiac output measurement with a simplified thermodilution technique. Comparison with the Fick method.
    Sibille L; Prasquier R; Vallois JM; Gaudebout C; Pocidalo JJ
    Biomedicine; 1975 Feb; 23(2):64-7. PubMed ID: 239762
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of cardiac output in man with a nonrecirculating indicator.
    Wittenberg SM; Klocke FJ; Greene DG; Bunnell IL; Falsetti HL; Zizzi JA
    J Clin Invest; 1971 Jul; 50(7):1466-72. PubMed ID: 4932984
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of the CO2 rebreathing method for measuring cardiac output in patients with hypertension or heart failure.
    Franciosa JA; Ragan DO; Rubenstone SJ
    J Lab Clin Med; 1976 Oct; 88(4):672-82. PubMed ID: 787459
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Observations on a model of proliferative lung disease. II. Description of pulmonary gas exchange and comparison of Fick and dye cardiac outputs.
    Caldwell PR; Echeverri U; Kilcoyne MM; Fritts HW
    J Clin Invest; 1970 Jul; 49(7):1311-5. PubMed ID: 4914677
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of cardiac output without right heart catheterization: reliability, advantages, and limitations of a left-sided indicator dilution technique.
    van den Berg E; Pacifico A; Lange RA; Wheelan KR; Winniford MD; Hillis LD
    Cathet Cardiovasc Diagn; 1986; 12(3):205-8. PubMed ID: 3524851
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new constant infusion radioisotopic technique for the noninvasive determination of cardiac output.
    Berman DS; Salel AF; DeNardo GL; Bell GB; Scheibe PO; Jackson PE; Mason DT
    Med Instrum; 1976; 10(4):195-204. PubMed ID: 785164
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Double indicator dilution method using heat and dye to measure pulmonary extravascular water volume].
    Arakawa M; Yasuda Y; Kambara K; Iinuma J; Miyazaki H; Segawa T; Hirakawa S
    J Cardiogr; 1985 Sep; 15(3):787-93. PubMed ID: 3915510
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A; Barnett AG; Mullany D; Fraser JF
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thermal dilution for measurement of cardiac output in the pulmonary artery in man in relation to choice of indicator volume and injection time.
    Enghoff E; Sjögren S
    Ups J Med Sci; 1973; 78(1):33-7. PubMed ID: 4573901
    [No Abstract]   [Full Text] [Related]  

  • 14. Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output.
    Hillis LD; Firth BG; Winniford MD
    Am J Cardiol; 1985 Nov; 56(12):764-8. PubMed ID: 3904383
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison between the thermal dilution method and the direct Fick and the dye dilution methods for cardiac output measurements in man.
    Enghoff E; Michaëlsson M; Pavek K; Sjögren S
    Acta Soc Med Ups; 1970; 75(3-4):157-70. PubMed ID: 4941433
    [No Abstract]   [Full Text] [Related]  

  • 16. Hepatic blood flow and oxygen consumption in starvation, sepsis and septic shock.
    Imamura M; Clowes GH
    Surg Gynecol Obstet; 1975 Jul; 141(1):27-34. PubMed ID: 1154209
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dilution methods for measurement of cardiac output: A review. SAM-TR-70-5.
    Farhi LE
    Tech Rep SAM-TR; 1970 Jan; ():143-50. PubMed ID: 4912342
    [No Abstract]   [Full Text] [Related]  

  • 18. Quasi-simultaneous cardiac output determinations in dogs with the direct Fick method (O2 and CO2) and with the dye dilution method using a linear reflection densitometer.
    ten Hoor F; Rispens P; Buursma A; Fongers TM; Jurriëns JM; Zijlma JA
    Pflugers Arch; 1970; 314(2):148-50. PubMed ID: 4903732
    [No Abstract]   [Full Text] [Related]  

  • 19. [A time-saving empirical method to calculate the area under dye dilution curves for the determination of cardiac output (author's transl)].
    Schad H; Brechtelsbauer H
    Anaesthesist; 1981 May; 30(5):243-5. PubMed ID: 7018321
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Comparative evaluation of impedance cardiographic and dye dilution methods in determining hemodynamic indices].
    Kaloianova A
    Vutr Boles; 1981; 20(4):93-8. PubMed ID: 7029910
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.