These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 7750358)

  • 1. Obstructive lung disease. Percutaneous needle biopsy.
    Spagnolo SV; Hill PC; Hockstein MJ
    Chest; 1995 May; 107(5):1476-7. PubMed ID: 7750358
    [No Abstract]   [Full Text] [Related]  

  • 2. Risk of pneumothorax and percutaneous needle biopsy.
    Dogra VS; Smeltzer JS
    Chest; 1995 May; 107(5):1477-8. PubMed ID: 7619136
    [No Abstract]   [Full Text] [Related]  

  • 3. Pneumothorax after fine-needle aspiration biopsy.
    Solli P; Cattelani L; Rusca M; Ganzetti A
    Radiology; 1998 Jul; 208(1):266-7. PubMed ID: 9646823
    [No Abstract]   [Full Text] [Related]  

  • 4. Include more patients in the study.
    Poe RH; Kallay MC
    Chest; 1995 Apr; 107(4):1181-2. PubMed ID: 7705142
    [No Abstract]   [Full Text] [Related]  

  • 5. Risk of pneumothorax not increased by obstructive lung disease in percutaneous needle biopsy.
    Anderson CL; Crespo JC; Lie TH
    Chest; 1994 Jun; 105(6):1705-8. PubMed ID: 8205864
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests.
    Fish GD; Stanley JH; Miller KS; Schabel SI; Sutherland SE
    AJR Am J Roentgenol; 1988 Jan; 150(1):71-4. PubMed ID: 3257134
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous needle biopsy of lung lesions.
    St Louis EL; Hyland R; Gray RR; Hutcheon M; Jones D; Grosman H
    Chest; 1984 Dec; 86(6):940-1. PubMed ID: 6499563
    [No Abstract]   [Full Text] [Related]  

  • 8. Delayed pneumothorax after CT-guided percutaneous fine needle aspiration lung biopsy.
    Traill ZC; Gleeson FV
    Thorax; 1997 Jun; 52(6):581-2; discussion 575-6. PubMed ID: 9227732
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transthoracic needle biopsy of lung in nonhospitalized patients.
    Poe RH; Kallay MC
    Chest; 1987 Oct; 92(4):676-8. PubMed ID: 3652752
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac arrest after percutaneous transthoracic needle biopsy: a consideration other than pneumothorax!
    Bollu M; Marte-Grau A; George SM; Bobba RK; Martin TJ
    Am J Med Sci; 2010 Aug; 340(2):155. PubMed ID: 20562594
    [No Abstract]   [Full Text] [Related]  

  • 11. The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor.
    Saji H; Nakamura H; Tsuchida T; Tsuboi M; Kawate N; Konaka C; Kato H
    Chest; 2002 May; 121(5):1521-6. PubMed ID: 12006438
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [CT-guided needle biopsy of the lung: factors affecting risk of complications].
    Fukushima A; Ashizawa K; Aso N; Takao M; Hayashi H; Nagaoki K; Sakamoto I; Hayashi K
    Nihon Igaku Hoshasen Gakkai Zasshi; 2001 Feb; 61(3):96-9. PubMed ID: 11265128
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pneumothorax risk prediction in lung needle biopsy by pulmonary function tests.
    García-Río F; Pino JM; Terreros-Caro JG; Prados C; Villamor J
    Chest; 1997 Apr; 111(4):1141-2. PubMed ID: 9106606
    [No Abstract]   [Full Text] [Related]  

  • 14. Percutaneous needle biopsy of the lung with a new disposable needle.
    Vitums VC
    Chest; 1972 Dec; 62(6):717-9. PubMed ID: 4635421
    [No Abstract]   [Full Text] [Related]  

  • 15. [The use of homologous coagulated blood for prevention of pneumothorax following percutaneous lung biopsy (experimental study)].
    Petsas T; Fezoulidis I; Siamplis D; Dimopoulos I
    Rofo; 1990 May; 152(5):565-8. PubMed ID: 2160690
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [X-ray guided percutaneous needle aspiration biopsy of the lung].
    Wang X
    Zhonghua Fang She Xue Za Zhi; 1986 Jun; 20(3):133-4. PubMed ID: 2944717
    [No Abstract]   [Full Text] [Related]  

  • 17. [Bilateral pneumothorax following CT-guided unilateral percutaneous lung biopsy].
    Klose KC
    Rofo; 1991 Apr; 154(4):445-6. PubMed ID: 1850163
    [No Abstract]   [Full Text] [Related]  

  • 18. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.
    Kakizawa H; Toyota N; Hieda M; Hirai N; Tachikake T; Matsuura N; Oda M; Ito K
    Hiroshima J Med Sci; 2010 Sep; 59(3):43-50. PubMed ID: 21265263
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous needle biopsy of the lung.
    Allison DJ; Hemingway AP
    Br Med J (Clin Res Ed); 1981 Mar; 282(6267):875-8. PubMed ID: 6783210
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous needle biopsy of the lung.
    Allison DJ; Hemingway AP
    Ann Radiol (Paris); 1982 Nov; 25(7):486-8. PubMed ID: 7165255
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.