These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

422 related articles for article (PubMed ID: 7758284)

  • 41. Surface characteristics and electrochemical corrosion behavior of NiTi alloy coated with IrO2.
    Li M; Wang YB; Zhang X; Li QH; Liu Q; Cheng Y; Zheng YF; Xi TF; Wei SC
    Mater Sci Eng C Mater Biol Appl; 2013 Jan; 33(1):15-20. PubMed ID: 25428036
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Corrosion resistance of Co-Cr, Ni-Cr, Ni-Cr-Ti alloy in artificial saliva].
    Sun P; Lu Y; Chen S
    Shanghai Kou Qiang Yi Xue; 2007 Dec; 16(6):652-6. PubMed ID: 18278423
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Corrosion resistance of a magnetic stainless steel ion-plated with titanium nitride.
    Hai K; Sawase T; Matsumura H; Atsuta M; Baba K; Hatada R
    J Oral Rehabil; 2000 Apr; 27(4):361-6. PubMed ID: 10792599
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Influence of finishing on the electrochemical properties of dental alloys.
    Kaneko T; Hattori M; Hasegawa K; Yoshinari M; Kawada E; Oda Y
    Bull Tokyo Dent Coll; 2000 May; 41(2):49-57. PubMed ID: 11212579
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Influence of different NaCl concentration on passive behavior of Cr alloy in vitro].
    Su RG; Wang SF; Zhang XF; Qu PL
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Jan; 45(1):49-51. PubMed ID: 20368042
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution.
    Montero-Ocampo C; Lopez H; Salinas Rodriguez A
    J Biomed Mater Res; 1996 Dec; 32(4):583-91. PubMed ID: 8953148
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions.
    Speck KM; Fraker AC
    J Dent Res; 1980 Oct; 59(10):1590-5. PubMed ID: 6932415
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Electrochemical behavior of titanium in artificial saliva: influence of pH.
    Abey S; Mathew MT; Lee DJ; Knoernschild KL; Wimmer MA; Sukotjo C
    J Oral Implantol; 2014 Feb; 40(1):3-10. PubMed ID: 22103963
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Corrosion of dental titanium alloys binary system of Ti-Al, Ti-Cu, Ti-Ni].
    Oda Y; Funasaka M; Sumii T
    Shika Zairyo Kikai; 1990 Mar; 9(2):314-9. PubMed ID: 2135523
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Corrosion behaviour of a beta-titanium alloy.
    Martin E; Manceur A; Polizu S; Savadogo O; Wu MH; Yahia L
    Biomed Mater Eng; 2006; 16(3):171-82. PubMed ID: 16518016
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires.
    Rondelli G; Vicentini B
    Biomaterials; 1999 Apr; 20(8):785-92. PubMed ID: 10353661
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Study on corrosion resistance of three non-noble porcelain alloys].
    Wu Z; Xu S; Li W; Teng J; Li N
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2011 Oct; 29(5):485-7, 493. PubMed ID: 22165115
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Cu-Ti, Co-Ti and Ni-Ti systems: corrosion and microhardness.
    Chern Lin JH; Moser JB; Taira M; Greener EH
    J Oral Rehabil; 1990 Jul; 17(4):383-93. PubMed ID: 2213334
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution.
    Burnat B; Walkowiak-Przybyło M; Błaszczyk T; Klimek L
    Acta Bioeng Biomech; 2013; 15(1):87-95. PubMed ID: 23957237
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Biocorrosion study of titanium-nickel alloys.
    Chern Lin JH; Lo SJ; Ju CP
    J Oral Rehabil; 1996 Feb; 23(2):129-34. PubMed ID: 8850064
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Tantalum Nitride-Decorated Titanium with Enhanced Resistance to Microbiologically Induced Corrosion and Mechanical Property for Dental Application.
    Zhang Y; Zheng Y; Li Y; Wang L; Bai Y; Zhao Q; Xiong X; Cheng Y; Tang Z; Deng Y; Wei S
    PLoS One; 2015; 10(6):e0130774. PubMed ID: 26107177
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity.
    Huang HH
    J Biomed Mater Res A; 2005 Sep; 74(4):629-39. PubMed ID: 16025472
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Biocorrosion study of titanium-cobalt alloys.
    Chern Lin JH; Lo SJ; Ju CP
    J Oral Rehabil; 1995 May; 22(5):331-5. PubMed ID: 7616342
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 22.