These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 7759145)

  • 21. Can protamine be used during perfusion with heparin surface coated equipment?
    von Segesser LK; Gyurech DD; Schilling JJ; Marquardt K; Turina MI
    ASAIO J; 1993; 39(3):M190-4. PubMed ID: 8268526
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A closed perfusion system with heparin coating and centrifugal pump improves cardiopulmonary bypass biocompatibility in elderly patients.
    Lindholm L; Westerberg M; Bengtsson A; Ekroth R; Jensen E; Jeppsson A
    Ann Thorac Surg; 2004 Dec; 78(6):2131-8; discussion 2138. PubMed ID: 15561050
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Long-term extracorporeal blood bypass in dogs at low flows without systemic heparinization. Heparin-coated versus uncoated circuits.
    van der Hulst VP; Gründeman PF; Moulijn AC; Rutten PJ; Klopper PJ
    ASAIO Trans; 1991; 37(4):577-83. PubMed ID: 1768492
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Changes in hemostasis during pediatric heart surgery: impact of a biocompatible heparin-coated perfusion system.
    Jensen E; Andréasson S; Bengtsson A; Berggren H; Ekroth R; Larsson LE; Ouchterlony J
    Ann Thorac Surg; 2004 Mar; 77(3):962-7. PubMed ID: 14992907
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [A clinical study on hemostatic fluctuation during and after cardiopulmonary bypass using hemostatic molecular markers].
    Nakajima H
    Nihon Kyobu Geka Gakkai Zasshi; 1992 Nov; 40(11):1987-97. PubMed ID: 1336789
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Ex vivo testing of heparin-coated extracorporeal circuits: bovine experiments.
    Weerwind PW; van der Veen FH; Lindhout T; de Jong DS; Cahalan PT
    Int J Artif Organs; 1998 May; 21(5):291-8. PubMed ID: 9684912
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Performance characteristics of centrifugal pumps with heparin surface coating.
    von Segesser LK; Lachat M; Gallino A; Weiss BM; Leskosek B; Garcia E; Hänseler E; von Felten A; Turina M
    Thorac Cardiovasc Surg; 1990 Aug; 38(4):224-8. PubMed ID: 2237882
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model.
    Lin PH; Chen C; Bush RL; Yao Q; Lumsden AB; Hanson SR
    J Vasc Surg; 2004 Jun; 39(6):1322-8. PubMed ID: 15192575
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Blood interaction with a Bioline heparin coated HIA-VAD: a study on calves.
    van der Kamp KW; Magielse CP; Elstrodt JM; van der Meer J; van Oeveren W; Rakhorst G
    Int J Artif Organs; 1997 Jan; 20(1):43-50. PubMed ID: 9062831
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Thrombosis-resistant heparin-coated diffusion membrane oxygenators: an experimental study].
    Tkebuchava T; von Segesser LK; Leskosek B; Pei P; Turina M
    Swiss Surg Suppl; 1996; Suppl 1():36-40. PubMed ID: 8653573
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Contact, coagulation and platelet interaction with heparin treated equipment during heart surgery.
    van der Kamp KW; van Oeveren W
    Int J Artif Organs; 1993 Dec; 16(12):836-42. PubMed ID: 8175200
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of polymethoxyethylacrylate-coated circuits with leukocyte filtration and reduced heparinization protocol on heparin-bonded circuits in different risk cohorts.
    Gunaydin S; McCusker K; Vijay V; Isbir S; Sari T; Onur MA; Gurpinar A; Sezgin A; Sargon MF; Tezcaner T; Zorlutuna Y
    Perfusion; 2006 Nov; 21(6):329-42. PubMed ID: 17312857
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical application of heparin-coated perfusion equipment with special emphasis on patients refusing homologous transfusions.
    von Segesser LK; Weiss BM; Garcia E; Turina MI
    Perfusion; 1991; 6(3):227-33. PubMed ID: 10171161
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of phospholipidic surface coatings ex-vivo.
    von Segesser LK; Tönz M; Leskosek B; Turina M
    Int J Artif Organs; 1994 May; 17(5):294-9. PubMed ID: 7960198
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biocompatibility of heparin-coated extracorporeal bypass circuits: a randomized, masked clinical trial.
    Muehrcke DD; McCarthy PM; Kottke-Marchant K; Harasaki H; Pierre-Yared J; Borsh JA; Ogella DA; Cosgrove DM
    J Thorac Cardiovasc Surg; 1996 Aug; 112(2):472-83. PubMed ID: 8751516
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Pump-induced platelet aggregation in albumin-coated extracorporeal systems.
    Borgdorff P; van den Berg RH; Vis MA; van den Bos GC; Tangelder GJ
    J Thorac Cardiovasc Surg; 1999 Nov; 118(5):946-52. PubMed ID: 10534702
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Off-pump coronary artery bypass operation does not increase procoagulant and fibrinolytic activity: preliminary results.
    Englberger L; Immer FF; Eckstein FS; Berdat PA; Haeberli A; Carrel TP
    Ann Thorac Surg; 2004 May; 77(5):1560-6. PubMed ID: 15111143
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinical and biomaterial evaluation of hyaluronan-based heparin-bonded extracorporeal circuits with reduced versus full systemic anticoagulation in reoperation for coronary revascularization.
    Gunaydin S; Farsak B; McCusker K; Vijay V; Sari T; Onur MA; Gurpinar A; Zorlutuna Y
    J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):135-42. PubMed ID: 19377380
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Heparin binding proteins. Contribution to heparin rebound after cardiopulmonary bypass.
    Teoh KH; Young E; Bradley CA; Hirsh J
    Circulation; 1993 Nov; 88(5 Pt 2):II420-5. PubMed ID: 8222188
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of a low molecular weight heparin (Fragmin) and of unfractionated heparin on coagulation activation at the site of plug formation in vivo.
    Eichinger S; Wolz M; Nieszpaur-Los M; Schneider B; Lechner K; Eichler HG; Kyrle PA
    Thromb Haemost; 1994 Dec; 72(6):831-5. PubMed ID: 7740450
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.