These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

68 related articles for article (PubMed ID: 7761013)

  • 1. [Comparative clinical evaluation of 4 heat and moisture exchangers (HME) in general anesthesia].
    Cornaggia G; Chidini G; Stella L
    Minerva Anestesiol; 1994 Nov; 60(11):649-55. PubMed ID: 7761013
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia.
    Luchetti M; Pigna A; Gentili A; Marraro G
    Paediatr Anaesth; 1999; 9(1):39-45. PubMed ID: 10712714
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation.
    Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C
    Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro and in vivo evaluation of a new active heat moisture exchanger.
    Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
    Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance.
    Thiéry G; Boyer A; Pigné E; Salah A; De Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):699-704. PubMed ID: 12626972
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Heat and moisture exchangers. Structure and function.
    Wilkes AR
    Respir Care Clin N Am; 1998 Jun; 4(2):261-79. PubMed ID: 9648186
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.
    Brusasco C; Corradi F; Vargas M; Bona M; Bruno F; Marsili M; Simonassi F; Santori G; Severgnini P; Kacmarek RM; Pelosi P
    Respir Care; 2013 Nov; 58(11):1878-85. PubMed ID: 23674812
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A New Method for
    Filippini M; Serpelloni M; Quaranta V; Bellitti P; Sardini E; Latronico N
    Pulm Med; 2019; 2019():9270615. PubMed ID: 30937191
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Comparison of 2 exchangers of heat and humidity in anesthesia (Hygrobac vs Ultipor BB50)].
    Zamaro G; Romano E; Molassi M
    Minerva Anestesiol; 1989 Sep; 55(9):363-5. PubMed ID: 2633085
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laboratory investigation of six artificial noses for use during endotracheal anesthesia.
    Weeks DB; Ramsey FM
    Anesth Analg; 1983 Aug; 62(8):758-63. PubMed ID: 6869864
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Changes in ventilation during use of heat and humidity exchangers].
    Croci M; Corrado F; Sibilla E; Tiby A; Vercesi G; Proietti D; Vannucci A
    Minerva Anestesiol; 1991; 57(1-2):13-6. PubMed ID: 2057084
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of nine heat and moisture exchangers for intraoperative airway heat conservation.
    Tsubota K; Harada J; Goto Y
    J Aerosol Med; 1991; 4(2):117-25. PubMed ID: 10147688
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Laboratory evaluation of heat and moisture exchangers. Assessment of the Draft International Standard (ISO/DIS 9360) in practice.
    Eckerbom B; Lindholm CE
    Acta Anaesthesiol Scand; 1990 May; 34(4):291-5. PubMed ID: 2343731
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tracheal climate in laryngectomees after use of a heat and moisture exchanger.
    Keck T; Dürr J; Leiacker R; Rettinger G; Rozsasi A
    Laryngoscope; 2005 Mar; 115(3):534-7. PubMed ID: 15744172
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of heat and moisture exchanger and gas flow on humidity and temperature in a circle anaesthetic system.
    Poopalalingam R; Goh MH; Chan YW
    Singapore Med J; 2002 Nov; 43(11):563-5. PubMed ID: 12680524
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate.
    Zuur JK; Muller SH; Vincent A; Sinaasappel M; de Jongh FH; Hilgers FJ
    Head Neck; 2008 Aug; 30(8):1072-82. PubMed ID: 18528903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of three different humidification systems during prolonged mechanical ventilation.
    Luchetti M; Stuani A; Castelli G; Marraro G
    Minerva Anestesiol; 1998 Mar; 64(3):75-81. PubMed ID: 9677791
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Heat and moisture exchange devices: are they doing what they are supposed to do?
    Lemmens HJM; Brock-Utne JG
    Anesth Analg; 2004 Feb; 98(2):382-385. PubMed ID: 14742374
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.