These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 7764438)
1. Development of a process-FIA system using mediator-modified enzyme electrodes. Gründig B; Strehlitz B; Kotte H; Ethner K J Biotechnol; 1993 Dec; 31(3):277-87. PubMed ID: 7764438 [TBL] [Abstract][Full Text] [Related]
2. Amperometric biosensors based on mediator-modified electrodes. Turner AP Methods Enzymol; 1988; 137():90-103. PubMed ID: 3374364 [No Abstract] [Full Text] [Related]
3. Bioaffinity layering: a novel strategy for the immobilization of large quantities of glycoenzymes. Farooqi M; Saleemuddin M; Ulber R; Sosnitza P; Scheper T J Biotechnol; 1997 Jul; 55(3):171-9. PubMed ID: 9249993 [TBL] [Abstract][Full Text] [Related]
4. Analytical aspects of internal signal processing in biosensors. Scheller FW; Pfeiffer D; Hintsche R; Dransfeld I; Wollenberger U; Schubert F Ann N Y Acad Sci; 1990; 613():68-78. PubMed ID: 2076012 [No Abstract] [Full Text] [Related]
5. Biosensing of glucose in flow injection analysis system based on glucose oxidase-quantum dot modified pencil graphite electrode. Sağlam Ö; Kızılkaya B; Uysal H; Dilgin Y Talanta; 2016 Jan; 147():315-21. PubMed ID: 26592613 [TBL] [Abstract][Full Text] [Related]
6. Flow injection analysis of mercury(II) in pharmaceuticals based on enzyme inhibition and biosensor detection. Bertocchi P; Ciranni E; Compagnone D; Magearu V; Palleschi G; Pirvutoiu S; Valvo L J Pharm Biomed Anal; 1999 Jun; 20(1-2):263-9. PubMed ID: 10704031 [TBL] [Abstract][Full Text] [Related]
7. Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis. Guémas Y; Boujtita M; el Murr N Appl Biochem Biotechnol; 2000; 89(2-3):171-81. PubMed ID: 11209461 [TBL] [Abstract][Full Text] [Related]
8. Nanoband array electrode as a platform for high sensitivity enzyme-based glucose biosensing. Falk M; Sultana R; Swann MJ; Mount AR; Freeman NJ Bioelectrochemistry; 2016 Dec; 112():100-5. PubMed ID: 27118384 [TBL] [Abstract][Full Text] [Related]
9. Fabrication of a glucose biosensor based on inserted barrel plating gold electrodes. Hsu CT; Chung HH; Tsai DM; Fang MY; Hsiao HC; Zen JM Anal Chem; 2009 Jan; 81(1):515-8. PubMed ID: 19046070 [TBL] [Abstract][Full Text] [Related]
10. Mimicked translocation of glucose and glucose 6-phosphate with artificial enzyme membranes. Maïsterrena B; Coulet PR Biochem J; 1989 Jun; 260(2):455-61. PubMed ID: 2764883 [TBL] [Abstract][Full Text] [Related]
11. Calorimetric analysis of sugars and sugar derivatives with aid of an enzyme thermistor. Mattiasson B; Danielsson B Carbohydr Res; 1982 Apr; 102():273-82. PubMed ID: 6807544 [TBL] [Abstract][Full Text] [Related]
12. Development of amperometric glucose biosensor through immobilizing enzyme in a Pt nanoparticles/mesoporous carbon matrix. Yu J; Yu D; Zhao T; Zeng B Talanta; 2008 Feb; 74(5):1586-91. PubMed ID: 18371821 [TBL] [Abstract][Full Text] [Related]