BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 7774323)

  • 21. Capnometry for continuous postoperative monitoring of nonintubated, spontaneously breathing patients.
    Lenz G; Heipertz W; Epple E
    J Clin Monit; 1991 Jul; 7(3):245-8. PubMed ID: 1909750
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of supplemental nocturnal oxygen on gas exchange in patients with severe obstructive lung disease.
    Goldstein RS; Ramcharan V; Bowes G; McNicholas WT; Bradley D; Phillipson EA
    N Engl J Med; 1984 Feb; 310(7):425-9. PubMed ID: 6420700
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of indirect methods for continuous estimation of arterial PCO2 in men.
    Robbins PA; Conway J; Cunningham DA; Khamnei S; Paterson DJ
    J Appl Physiol (1985); 1990 Apr; 68(4):1727-31. PubMed ID: 2112130
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of arterial-end-tidal PCO2 difference and dead space/tidal volume ratio in respiratory failure.
    Yamanaka MK; Sue DY
    Chest; 1987 Nov; 92(5):832-5. PubMed ID: 3117500
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Variability of blood gases, pulse oximeter saturation, and end-tidal carbon dioxide pressure in stable, mechanically ventilated trauma patients.
    Hess D; Agarwal NN
    J Clin Monit; 1992 Apr; 8(2):111-5. PubMed ID: 1583545
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Current correction factors inadequately predict the relationship between transcutaneous (tc) and arterial PCO2 in sick neonates.
    Martin RJ; Beoglos A; Miller MJ; DiFiore JM; Carlo WA
    Adv Exp Med Biol; 1987; 220():51-3. PubMed ID: 3118655
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of transcutaneous oxygen and carbon dioxide monitors in normal adults and critically ill patients.
    Rithalia SV; Farrow P; Doran BR
    Intensive Crit Care Nurs; 1992 Mar; 8(1):40-6. PubMed ID: 1559023
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Translaryngeal jet ventilation and end-tidal PCO2 monitoring during varying degrees of upper airway obstruction.
    Ward KR; Menegazzi JJ; Yealy DM; Klain MM; Molner RL; Goode JS
    Ann Emerg Med; 1991 Nov; 20(11):1193-7. PubMed ID: 1952304
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Discrepancies between transcutaneous and end-tidal carbon dioxide monitoring in the critically ill neonate with respiratory distress syndrome.
    Hand IL; Shepard EK; Krauss AN; Auld PA
    Crit Care Med; 1989 Jun; 17(6):556-9. PubMed ID: 2498038
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of respiratory inductive plethysmography during wakefulness and sleep in patients with obstructive sleep apnea.
    Cantineau JP; Escourrou P; Sartene R; Gaultier C; Goldman M
    Chest; 1992 Oct; 102(4):1145-51. PubMed ID: 1395758
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Relationship between invasive and noninvasive measurements of gas exchange in anesthetized infants and children.
    Lindahl SG; Yates AP; Hatch DJ
    Anesthesiology; 1987 Feb; 66(2):168-75. PubMed ID: 3101550
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Use of capnography and transcutaneous oxygen monitoring during outpatient general anesthesia for oral surgery.
    Anderson JA; Clark PJ; Kafer ER
    J Oral Maxillofac Surg; 1987 Jan; 45(1):3-10. PubMed ID: 3098942
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Response characteristics of a dual transcutaneous oxygen/carbon dioxide monitoring system.
    Kesten S; Chapman KR; Rebuck AS
    Chest; 1991 May; 99(5):1211-5. PubMed ID: 2019180
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The relationship between the arterial to end-tidal PCO2 difference and hemoglobin saturation in patients with congenital heart disease.
    Fletcher R
    Anesthesiology; 1991 Aug; 75(2):210-6. PubMed ID: 1907112
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Combined transcutaneous oxygen, carbon dioxide tensions and end-expired CO2 levels in severely ill newborns.
    Geven WB; Nagler E; de Boo T; Lemmens W
    Adv Exp Med Biol; 1987; 220():115-20. PubMed ID: 3118653
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcutaneous noninvasive monitoring of carbon dioxide tension.
    Greenspan GH; Block AJ; Haldeman LW; Lindsey S; Martin CS
    Chest; 1981 Oct; 80(4):442-6. PubMed ID: 6791884
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A possible mechanism for mixed apnea in obstructive sleep apnea.
    Iber C; Davies SF; Chapman RC; Mahowald MM
    Chest; 1986 Jun; 89(6):800-5. PubMed ID: 3086045
    [TBL] [Abstract][Full Text] [Related]  

  • 38. End-tidal carbon dioxide pressure in neonates and infants measured by aspiration and flow-through capnography.
    Badgwell JM; Heavner JE
    J Clin Monit; 1991 Oct; 7(4):285-8. PubMed ID: 1744671
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monitoring end-tidal carbon dioxide tensions with high-frequency jet ventilation in dogs with normal lungs.
    Mihm FG; Feeley TW; Rodarte A
    Crit Care Med; 1984 Mar; 12(3):180-2. PubMed ID: 6421542
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Relationship between arterial carbon dioxide and end-tidal carbon dioxide when a nasal sampling port is used.
    McNulty SE; Roy J; Torjman M; Seltzer JL
    J Clin Monit; 1990 Apr; 6(2):93-8. PubMed ID: 2112592
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.