These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 7775493)

  • 1. Stress protection due to external fixation.
    O'Doherty DM; Butler SP; Goodship AE
    J Biomech; 1995 May; 28(5):575-86. PubMed ID: 7775493
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cortical bone reactions at the interface of external fixation half-pins under different loading conditions.
    Aro HT; Markel MD; Chao EY
    J Trauma; 1993 Nov; 35(5):776-85. PubMed ID: 8230346
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of the external fixator pin-bone interface.
    Pettine KA; Chao EY; Kelly PJ
    Clin Orthop Relat Res; 1993 Aug; (293):18-27. PubMed ID: 8339479
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Strain gauge measurements on a one-side external fixation: a prospective series of 11 tibial shaft fractures].
    Fragnière B; Chevalley F
    Rev Chir Orthop Reparatrice Appar Mot; 2001 Nov; 87(7):669-76. PubMed ID: 11845070
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Axial preload in external fixator half-pins: a preliminary mechanical study of an experimental bone anchorage system.
    Karnezis IA; Miles AW; Cunningham JL; Learmonth ID
    Clin Biomech (Bristol); 1999 Jan; 14(1):69-73. PubMed ID: 10619092
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro biomechanical testing of different configurations of acrylic external skeletal fixator constructs.
    Tyagi SK; Aithal HP; Kinjavdekar P; Amarpal ; Pawde AM; Srivastava T; Singh J; Madhu DN
    Vet Comp Orthop Traumatol; 2015; 28(4):227-33. PubMed ID: 25998130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study.
    Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC;
    J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical properties of the Pinless external fixator on human tibiae.
    Remiger AR
    Injury; 1992; 23 Suppl 3():S28-43. PubMed ID: 1286919
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical evaluation of various external skeletal fixator-intramedullary pin tie-in configurations using a tubular plastic bone model.
    Van Wettere AJ; Wallace LJ; Redig PT; Bourgeault CA; Bechtold JE
    J Avian Med Surg; 2009 Dec; 23(4):263-76. PubMed ID: 20235457
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A strain-gauge study of the effect of external fixation on the canine tibia.
    Matushek KJ; Sumner-Smith G; Schatzker J; Hearn TC; Taves C; Hoare J
    Arch Orthop Trauma Surg; 1989; 108(3):159-65. PubMed ID: 2730298
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interruption of disuse by short duration walking exercise does not prevent bone loss in the sheep calcaneus.
    Skerry TM; Lanyon LE
    Bone; 1995 Feb; 16(2):269-74. PubMed ID: 7756057
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Geometrical properties of the ovine tibia: a suitable animal model to study the pin-bone interface in fracture fixation?
    Finlay JB; Hurtig MB; Hardie WR; Liggins AB; Batte SW
    Proc Inst Mech Eng H; 1995; 209(1):37-50. PubMed ID: 7669119
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins. An in vivo study in sheep.
    Moroni A; Toksvig-Larsen S; Maltarello MC; Orienti L; Stea S; Giannini S
    J Bone Joint Surg Am; 1998 Apr; 80(4):547-54. PubMed ID: 9563384
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
    Podolsky A; Chao EY
    Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A finite element analysis for monitoring the healing progression of fixator-bone system under three loading conditions.
    Li J; Zhao X; Hu X; Tao C; Ji R
    Biomed Mater Eng; 2018; 29(4):473-483. PubMed ID: 30282344
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The role of fixator frame stiffness in the control of fracture healing. An experimental study.
    Goodship AE; Watkins PE; Rigby HS; Kenwright J
    J Biomech; 1993 Sep; 26(9):1027-35. PubMed ID: 8408085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The pin-bone interface in external fixator: a standardized analysis in a sheep osteotomy model.
    Schell H; Reuther T; Duda GN; Lienau J
    J Orthop Trauma; 2011 Jul; 25(7):438-45. PubMed ID: 21637126
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stress protection by external fixation of the rabbit tibia.
    Adolphson P; Jonsson U; Dalén N; Ehrnberg A
    Acta Orthop Scand; 1990 Aug; 61(4):324-6. PubMed ID: 2402983
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monitoring in vivo load transmission through an external fixator.
    Grasa J; Gómez-Benito MJ; González-Torres LA; Asiaín D; Quero F; García-Aznar JM
    Ann Biomed Eng; 2010 Mar; 38(3):605-12. PubMed ID: 20052616
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical stress on tensioned wires at direct and indirect loading: a biomechanical study on the Ilizarov external fixator.
    Gessmann J; Jettkant B; Schildhauer TA; Seybold D
    Injury; 2011 Oct; 42(10):1107-11. PubMed ID: 21392761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.