These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
147 related articles for article (PubMed ID: 7775698)
1. Characteristics of the ventilator pressure- and flow-trigger variables. Sassoon CS; Gruer SE Intensive Care Med; 1995 Feb; 21(2):159-68. PubMed ID: 7775698 [TBL] [Abstract][Full Text] [Related]
2. Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing. Messinger G; Banner MJ; Blanch PB; Layon AJ Chest; 1995 Aug; 108(2):509-14. PubMed ID: 7634891 [TBL] [Abstract][Full Text] [Related]
3. Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300. Calzia E; Lindner KH; Stahl W; Martin A; Radermacher P; Georgieff M Intensive Care Med; 1998 Sep; 24(9):931-8. PubMed ID: 9803329 [TBL] [Abstract][Full Text] [Related]
4. Jet flow-regulated expiratory resistance to maintain constant CPAP during the entire respiratory phase. Nishimura M; Takezawa J; Imanaka H; Taenaka N; Yoshiya I Chest; 1989 Apr; 95(4):876-80. PubMed ID: 2647423 [TBL] [Abstract][Full Text] [Related]
5. Effects of different triggering systems and external PEEP on trigger capability of the ventilator. Konyukov YA; Kuwayama N; Fukuoka T; Takahashi T; Mayumi T; Hotta T; Takezawa J Intensive Care Med; 1996 Apr; 22(4):363-8. PubMed ID: 8708177 [TBL] [Abstract][Full Text] [Related]
6. Comparison of pressure and flow triggering systems during continuous positive airway pressure. Branson RD; Campbell RS; Davis K; Johnson DJ Chest; 1994 Aug; 106(2):540-4. PubMed ID: 7774334 [TBL] [Abstract][Full Text] [Related]
7. Continuous positive airway pressure in new-generation mechanical ventilators: a lung model study. Takeuchi M; Williams P; Hess D; Kacmarek RM Anesthesiology; 2002 Jan; 96(1):162-72. PubMed ID: 11753017 [TBL] [Abstract][Full Text] [Related]
8. Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure. Tan IK; Bhatt SB; Tam YH; Buckley TA; Oh TE Intensive Care Med; 1995 Dec; 21(12):1023-6. PubMed ID: 8750128 [TBL] [Abstract][Full Text] [Related]
9. Pressure vs flow triggering during pressure support ventilation. Goulet R; Hess D; Kacmarek RM Chest; 1997 Jun; 111(6):1649-53. PubMed ID: 9187188 [TBL] [Abstract][Full Text] [Related]
10. Performance characteristics of bilevel pressure ventilators: a lung model study. Bunburaphong T; Imanaka H; Nishimura M; Hess D; Kacmarek RM Chest; 1997 Apr; 111(4):1050-60. PubMed ID: 9106588 [TBL] [Abstract][Full Text] [Related]
11. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861 [TBL] [Abstract][Full Text] [Related]
12. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief? Maeda Y; Fujino Y; Uchiyama A; Taenaka N; Mashimo T; Nishimura M Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975 [TBL] [Abstract][Full Text] [Related]
13. Total inspiratory work with modern demand valve devices compared to continuous flow CPAP. Samodelov LF; Falke KJ Intensive Care Med; 1988; 14(6):632-9. PubMed ID: 3053843 [TBL] [Abstract][Full Text] [Related]
14. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support. Fujino Y; Uchiyama A; Mashimo T; Nishimura M Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260 [TBL] [Abstract][Full Text] [Related]
15. Inspiratory effort and measurement of dynamic intrinsic PEEP in COPD patients: effects of ventilator triggering systems. Ranieri VM; Mascia L; Petruzzelli V; Bruno F; Brienza A; Giuliani R Intensive Care Med; 1995 Nov; 21(11):896-903. PubMed ID: 8636521 [TBL] [Abstract][Full Text] [Related]
16. The effect of ventilator performance on airway pressure release ventilation: a model lung study. Yoshida T; Uchiyama A; Mashimo T; Fujino Y Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042 [TBL] [Abstract][Full Text] [Related]
17. Comparison of inspiratory work of breathing between flow-triggered and pressure-triggered demand flow systems in rabbits. Nishimura M; Imanaka H; Yoshiya I; Kacmarek RM Crit Care Med; 1994 Jun; 22(6):1002-9. PubMed ID: 8205807 [TBL] [Abstract][Full Text] [Related]
18. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing. Aerts JG; van den Berg B; Bogaard JM Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of pressure support ventilation with seven different ventilators using Active Servo Lung 5000. Terado M; Ichiba S; Nagano O; Ujike Y Acta Med Okayama; 2008 Apr; 62(2):127-33. PubMed ID: 18464889 [TBL] [Abstract][Full Text] [Related]
20. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system. Banner MJ; Blanch PB; Kirby RR Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]