These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
168 related articles for article (PubMed ID: 7777417)
41. Combination biphasic waveform plus sequential pulse defibrillation improves defibrillation efficacy of a nonthoracotomy lead system. Exner D; Yee R; Jones DL; Klein GJ; Mehra R J Am Coll Cardiol; 1994 Feb; 23(2):317-22. PubMed ID: 8294680 [TBL] [Abstract][Full Text] [Related]
42. Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator. Brugada J; Herse B; Sandsted B; Michel U; Schubert BD; Hahn SJ Europace; 2001 Oct; 3(4):278-84. PubMed ID: 11678385 [TBL] [Abstract][Full Text] [Related]
43. Comparison of single-biphasic versus sequential-biphasic shocks on defibrillation threshold in pigs. Csanadi Z; Jones DL; Wood GK; Klein GJ Pacing Clin Electrophysiol; 1997 Jun; 20(6):1606-12. PubMed ID: 9227756 [TBL] [Abstract][Full Text] [Related]
44. Direct comparison of monophasic, biphasic and sequential pulse defibrillation over a single current pathway. Thakur R; Souza JJ; Chapman PD; Troup PJ; Wetherbee JN Can J Cardiol; 1996 Apr; 12(4):407-11. PubMed ID: 8608460 [TBL] [Abstract][Full Text] [Related]
45. Electrode system influence on biphasic waveform defibrillation efficacy in humans. Bardy GH; Troutman C; Johnson G; Mehra R; Poole JE; Dolack GL; Kudenchuk PJ; Gartman DM Circulation; 1991 Aug; 84(2):665-71. PubMed ID: 1860210 [TBL] [Abstract][Full Text] [Related]
46. Defibrillation using a high-frequency series of monophasic rectangular pulses: observations and model predictions. Sweeney RJ; Gill RM; Jones JL; Reid PR J Cardiovasc Electrophysiol; 1996 Feb; 7(2):134-43. PubMed ID: 8853023 [TBL] [Abstract][Full Text] [Related]
47. Effect of biphasic waveform pulse on endocardial defibrillation efficacy in humans. Neuzner J; Pitschner HF; Huth C; Schlepper M Pacing Clin Electrophysiol; 1994 Feb; 17(2):207-12. PubMed ID: 7513406 [TBL] [Abstract][Full Text] [Related]
48. Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system. Yamanouchi Y; Mowrey KA; Nadzam GR; Hills DG; Kroll MW; Brewer JE; Donohoo AM; Wilkoff BL; Tchou PJ Pacing Clin Electrophysiol; 1997 Dec; 20(12 Pt 1):2911-6. PubMed ID: 9455750 [TBL] [Abstract][Full Text] [Related]
49. Optimization of transthoracic ventricular defibrillation-biphasic and triphasic shocks, waveform rounding, and synchronized shock delivery. Kidwai BJ; McIntyre A; Anderson J; Adgey AA J Electrocardiol; 2002 Jul; 35(3):235-44. PubMed ID: 12122614 [TBL] [Abstract][Full Text] [Related]
50. Surgical open-chest ventricular defibrillation: triphasic waveforms are superior to biphasic waveforms. Zhang Y; Boddicker KA; Davies LR; Jones JL; Kerber RE Pacing Clin Electrophysiol; 2004 Jul; 27(7):941-8. PubMed ID: 15271014 [TBL] [Abstract][Full Text] [Related]
51. A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans. Bardy GH; Ivey TD; Allen MD; Johnson G; Mehra R; Greene HL J Am Coll Cardiol; 1989 Sep; 14(3):728-33. PubMed ID: 2768721 [TBL] [Abstract][Full Text] [Related]
52. Prospective comparison of sequential pulse and single pulse defibrillation with use of two different clinically available systems. Bardy GH; Ivey TD; Allen MD; Johnson G; Greene HL J Am Coll Cardiol; 1989 Jul; 14(1):165-71. PubMed ID: 2738261 [TBL] [Abstract][Full Text] [Related]
53. Defibrillation efficacy of commercially available biphasic impulses in humans. Importance of negative-phase peak voltage. Tomassoni G; Newby K; Deshpande S; Axtell K; Sra J; Akhtar M; Natale A Circulation; 1997 Apr; 95(7):1822-6. PubMed ID: 9107169 [TBL] [Abstract][Full Text] [Related]
54. A direct comparison of epicardial and nonthoracotomy defibrillation using monophasic and biphasic shocks. Thakur RK; Souza JJ; Troup PJ; Chapman PD; Wetherbee JN Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 1):70-4. PubMed ID: 7700834 [TBL] [Abstract][Full Text] [Related]
55. Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy. Jones JL; Swartz JF; Jones RE; Fletcher R Circ Res; 1990 Aug; 67(2):376-84. PubMed ID: 2376078 [TBL] [Abstract][Full Text] [Related]
56. Improved internal defibrillation efficacy with a biphasic waveform. Fain ES; Sweeney MB; Franz MR Am Heart J; 1989 Feb; 117(2):358-64. PubMed ID: 2916410 [TBL] [Abstract][Full Text] [Related]
58. Low-energy endocardial defibrillation using an axillary or a pectoral thoracic electrode location. Saksena S; DeGroot P; Krol RB; Raju R; Mathew P; Mehra R Circulation; 1993 Dec; 88(6):2655-60. PubMed ID: 8252676 [TBL] [Abstract][Full Text] [Related]
59. The effects of second and third phase duration on defibrillation efficacy of triphasic rectangle waveforms. Tang C; Wang P; Gong Y; Wei L; Li Y; Zhang S Resuscitation; 2016 May; 102():57-62. PubMed ID: 26939971 [TBL] [Abstract][Full Text] [Related]
60. Encircling overlapping multipulse shock waveforms for transthoracic defibrillation. Pagan-Carlo LA; Allan JJ; Spencer KT; Birkett CL; Myers R; Kerber RE J Am Coll Cardiol; 1998 Dec; 32(7):2065-71. PubMed ID: 9857894 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]