These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

52 related articles for article (PubMed ID: 7786702)

  • 21. Infrainguinal vein graft surveillance: how and when.
    Mills JL
    Semin Vasc Surg; 2001 Sep; 14(3):169-76. PubMed ID: 11561277
    [TBL] [Abstract][Full Text] [Related]  

  • 22. One-point measurement of the peak-to-peak pulsatility index as an indicator for evaluation of infrainguinal bypass procedures.
    Inoue Y; Iwai T; Kubota T; Kure N; Muraoka Y; Endo M
    Surg Today; 1997; 27(4):305-9. PubMed ID: 9086545
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hemodynamic changes associated with bypass stenosis regression.
    Taggert JB; Kupinski AM; Darling RC; Trub M; Paty PS
    J Vasc Surg; 2005 Jun; 41(6):1013-7. PubMed ID: 15944602
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Duplex imaging of lower limb arterial bypass grafts.
    O'Ríordáin DS; Ryder DQ; O'Donnell JA
    Ir J Med Sci; 1992 Mar; 161(3):75-7. PubMed ID: 1387633
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transfer function index of pulse volume recordings: a new method for vein graft surveillance.
    Ihlberg LH; Mätzke S; Albäck NA; Roth WD; Sovijärvi AR; Lepäntalo M
    J Vasc Surg; 2001 Mar; 33(3):546-53. PubMed ID: 11241126
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Lower-extremity vascular grafts placed for peripheral vascular disease: prospective evaluation with duplex Doppler sonography.
    Gooding GA; Perez S; Rapp JH; Krupski WC
    Radiology; 1991 Aug; 180(2):379-86. PubMed ID: 2068299
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of hemodynamic conditions on sonographic measurements of peak systolic velocity and arterial diameter in patients with peripheral arterial stenosis.
    Kröger K; Massalha K; Buss C; Rudofsky G
    J Clin Ultrasound; 2000 Mar; 28(3):109-14. PubMed ID: 10679696
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Theoretical hydraulic consequences of vein graft taper.
    Lee SW; Curi MA; Baldwin ZK; Balasubramanian V; Loth F; Schwartz LB
    J Vasc Surg; 2003 Oct; 38(4):785-92. PubMed ID: 14560231
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The hemodynamics of vein graft stenosis.
    Belkin M
    Semin Vasc Surg; 1993 Jun; 6(2):111-7. PubMed ID: 8252232
    [No Abstract]   [Full Text] [Related]  

  • 30. Access to occluded infrainguinal bypass grafts with a loopsnare.
    Nosher JL; Siegel RL; Bodner LJ
    J Vasc Surg; 1999 Apr; 29(4):745-7. PubMed ID: 10194510
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The hemodynamics of vein grafts: measurement and meaning.
    Skelly CL; Meyerson SL; Curi MA; Loth F; Schwartz LB
    Ann Vasc Surg; 2001 Jan; 15(1):110-22. PubMed ID: 11221936
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Vein grafts: haemodynamic forces on the endothelium--a review.
    Golledge J
    Eur J Vasc Endovasc Surg; 1997 Nov; 14(5):333-43. PubMed ID: 9413373
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of a piezoelectric film sensor for monitoring vascular grafts.
    Gupta SK; Dietzek AM; Veith FJ; Torres M; Kram HB; Wengerter KR
    Am J Surg; 1990 Aug; 160(2):182-5; discussion 185-6. PubMed ID: 2382771
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dynamics of blood flow in stenotic vascular lesions.
    Rodbard S
    Am Heart J; 1966 Nov; 72(5):698-704. PubMed ID: 5923052
    [No Abstract]   [Full Text] [Related]  

  • 35. Mopping up crystals to keep the blood flowing.
    Hagemeyer CE
    EBioMedicine; 2022 Jan; 75():103786. PubMed ID: 34963098
    [No Abstract]   [Full Text] [Related]  

  • 36. Long-term patency and complications of ringed polytetrafluoroethylene grafts used for middle hepatic vein reconstruction in living-donor liver transplantation.
    Jung IJ; Hwang S; Ha TY; Song GW; Jung DH; Ahn CS; Moon DB; Kim KH; Park GC; Yoon YI; Park YH; Cho HD; Kwon JH; Chung YK; Kang SH; Lee SG
    Korean J Transplant; 2020 Mar; 34(1):31-37. PubMed ID: 35770268
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Patency of Hemashield grafts versus ringed Gore-Tex grafts in middle hepatic vein reconstruction for living donor liver transplantation.
    Kim SH; Hwang S; Kim M; Ha TY; Song GW; Jung DH; Ahn CS; Moon DB; Kim KH; Park GC; Lee SG
    Ann Hepatobiliary Pancreat Surg; 2021 Feb; 25(1):46-53. PubMed ID: 33649254
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Hemashield Vascular Graft Is a Preferable Prosthetic Graft for Middle Hepatic Vein Reconstruction in Living Donor Liver Transplantation.
    Park GC; Hwang S; Ha TY; Song GW; Jung DH; Ahn CS; Moon DB; Kim KH; Yoon YI; Cho HD; Kwon JH; Chung YK; Kang SH; Jung IJ; Choi JU; Lee SG
    Ann Transplant; 2019 Dec; 24():639-646. PubMed ID: 31844037
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Usability of Cryopreserved Aortic Allografts for Middle Hepatic Vein Reconstruction During Living-Donor Liver Transplantation.
    Kim SH; Hwang S; Ha TY; Song GW; Jung DH; Ahn CS; Moon DB; Kim KH; Park GC; Lee SG
    J Gastrointest Surg; 2016 May; 20(5):1049-55. PubMed ID: 26666546
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hemodynamics of stenotic infrainguinal vein grafts: theoretic considerations.
    Papanicolaou G; Beach KW; Zierler RE; Detmer PR; Strandness DE
    Ann Vasc Surg; 1995 Mar; 9(2):163-71. PubMed ID: 7786702
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 3.