  • 1. Prolonged interference of blue dye "patent blue" with pulse oximetry readings.
    Saito S; Fukura H; Shimada H; Fujita T
    Acta Anaesthesiol Scand; 1995 Feb; 39(2):268-9. PubMed ID: 7793197
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Oximetry and patent blue five dye.
    McEwan D; Lam K
    Anaesth Intensive Care; 1997 Oct; 25(5):587-8. PubMed ID: 9352783
    [No Abstract]   [Full Text] [Related]  

  • 3. The influence of patent blue V on pulse oximetry and haemoximetry.
    Larsen VH; Freudendal-Pedersen A; Fogh-Andersen N
    Acta Anaesthesiol Scand Suppl; 1995; 107():53-5. PubMed ID: 8599298
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Patent blue sentinel node mapping in cervical cancer patients may lead to decreased pulse oximeter readings and positive methaemoglobin results.
    Kieckbusch H; Coldewey SM; Hollenhorst J; Haeseler G; Hillemanns P; Hertel H
    Eur J Anaesthesiol; 2008 May; 25(5):365-8. PubMed ID: 18272013
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interference of patent blue dye with pulse oximetry readings, methemoglobin measurements, and blue urine in sentinel lymph node mapping: a case report and review of the literature.
    Lai HC; Hsu HM; Cherng CH; Lin SL; Wu CT; Yu JC; Yeh CC
    Acta Anaesthesiol Taiwan; 2011 Dec; 49(4):162-4. PubMed ID: 22221691
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulse oximetry and patent blue vital dye.
    Lee BB
    Acta Anaesthesiol Scand; 2003 Apr; 47(4):491; author reply 491. PubMed ID: 12694153
    [No Abstract]   [Full Text] [Related]  

  • 7. Prolonged interference of patent blue on pulse oximetry readings.
    Chia YY; Liu K; Kao PF; Sun GC; Wang KY
    Acta Anaesthesiol Sin; 2001 Mar; 39(1):27-32. PubMed ID: 11407292
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Changes in pulse oximetry after patent blue dye injection into the uterine cervix.
    Vieira SC; Sousa RB; Tavares MB; de Abreu BA; Ibiapina JO; de Sousa Oliveira AK; Zeferino LC
    Ann Surg Oncol; 2008 Oct; 15(10):2862-6. PubMed ID: 18696155
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Anaphylaxis and other adverse reactions to blue dyes: a case series.
    Howard JD; Moo V; Sivalingam P
    Anaesth Intensive Care; 2011 Mar; 39(2):287-92. PubMed ID: 21485680
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative decrease in pulse oximeter readings following injection of isosulfan blue.
    Hoskin RW; Granger R
    Can J Anaesth; 2001 Jan; 48(1):38-40. PubMed ID: 11212047
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A case of prolonged reduction in arterial oxygen saturation measured by pulse oxymetry after administering patent blue in an elderly patient].
    Takahashi Y; Hara K; Sata T
    Masui; 2013 Apr; 62(4):442-4. PubMed ID: 23697198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect on oximetry of dyes used for sentinel lymph node biopsy.
    Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P
    Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factitious oxygen desaturation after isosulfan blue injection.
    Heinle E; Burdumy T; Recabaren J
    Am Surg; 2003 Oct; 69(10):899-901. PubMed ID: 14570371
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous intra-arterial oximetry, pulse oximetry, and co-oximetry during cardiac surgery.
    Haessler R; Brandl F; Zeller M; Briegel J; Peter K
    J Cardiothorac Vasc Anesth; 1992 Dec; 6(6):668-73. PubMed ID: 1472661
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [False decrease in pulse oximetry readings due to patent blue in a patient with breast cancer].
    Murakami T; Kayo R; Kajita I; Cho S; Saito H
    Masui; 2003 Aug; 52(8):909-11. PubMed ID: 13677292
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [False low oximetry reading caused by patent blue vital dye during breast surgery].
    Nasif LA; Campos JM; Piñol S; Delgado MO; Casas JI; Landeira JM
    Rev Esp Anestesiol Reanim; 2005 Mar; 52(3):169-71. PubMed ID: 15850305
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effects of Patent Blue dye on peripheral and cerebral oxyhaemoglobin saturations.
    Ishiyama T; Kotoda M; Asano N; Ikemoto K; Mitsui K; Sato H; Matsukawa T; Sessler DI
    Anaesthesia; 2015 Apr; 70(4):429-33. PubMed ID: 25389044
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Brutal decrease in pulse oxymetry in paediatric anaesthesia: a story of artefact].
    Danin PE; Semjen F; Nouette-Gaulain K
    Ann Fr Anesth Reanim; 2011 May; 30(5):440-2. PubMed ID: 21481563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unexplained decrease in measured oxygen saturation by pulse oximetry following injection of Lymphazurin 1% (isosulfan blue) during a lymphatic mapping procedure.
    Coleman RL; Whitten CW; O'Boyle J; Sidhu B
    J Surg Oncol; 1999 Feb; 70(2):126-9. PubMed ID: 10084657
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse oximeter changes with sentinel lymph node biopsy in breast cancer.
    El-Tamer M; Komenaka IK; Curry S; Troxel AB; Ditkoff BA; Schnabel FR
    Arch Surg; 2003 Nov; 138(11):1257-60. PubMed ID: 14609878