These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 7794488)

  • 41. Dosimetric evaluation of newly developed well-type ionization chamber for use in the calibration of brachytherapy sources.
    Saminathan S; Godson HF; Ponmalar R; Manickam R; Mazarello J
    J Med Phys; 2016; 41(4):234-239. PubMed ID: 28144115
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Consistency of vendor-specified activity values for ¹⁹²Ir brachytherapy sources.
    Austerlitz C; Wolfe M; Campos D; Sibata CH
    Med Dosim; 2012; 37(1):67-70. PubMed ID: 21741822
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Lessons learned from a HDR brachytherapy well ionisation chamber calibration error.
    Dempsey C
    Australas Phys Eng Sci Med; 2011 Dec; 34(4):529-33. PubMed ID: 21858526
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A technique for calibrating a high dose rate ¹⁹²Ir brachytherapy source.
    Fourie OL; Crabtree TG
    Australas Phys Eng Sci Med; 2012 Mar; 35(1):85-92. PubMed ID: 22187355
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments.
    Visser AG; van den Aardweg GJ; Levendag PC
    Int J Radiat Oncol Biol Phys; 1996 Jan; 34(2):497-505. PubMed ID: 8567354
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A simplified analytical approach to estimate the parameters required for strength determination of HDR 192Ir brachytherapy sources using a Farmer-type ionization chamber.
    Kumar S; Srinivasan P; Sharma SD; Mayya YS
    Appl Radiat Isot; 2012 Jan; 70(1):282-9. PubMed ID: 21872480
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Thermal and scatter effects on the radiation sensitivity of well chambers used for high dose rate Ir-192 calibrations.
    Podgorsak MB; DeWerd LA; Thomadsen BR; Paliwal BR
    Med Phys; 1992; 19(5):1311-4. PubMed ID: 1435615
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Calibration of a Microselectron HDR iridium 192 source.
    Flynn A; Workman G
    Br J Radiol; 1991 Aug; 64(764):734-9. PubMed ID: 1884123
    [TBL] [Abstract][Full Text] [Related]  

  • 49. LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.
    King CR
    Brachytherapy; 2002; 1(4):219-26. PubMed ID: 15062170
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A reference air kerma rate calibration protocol for a 370 GBq 192Ir high dose rate brachytherapy source.
    Wallace AB
    Australas Phys Eng Sci Med; 1997 Jun; 20(2):64-70. PubMed ID: 9262025
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The irradiation tolerance dose of the proximal vagina.
    Au SP; Grigsby PW
    Radiother Oncol; 2003 Apr; 67(1):77-85. PubMed ID: 12758243
    [TBL] [Abstract][Full Text] [Related]  

  • 53. HDR source calibration methods and discrepancies.
    Nair MT; Cheng MC
    Int J Radiat Oncol Biol Phys; 1997 Apr; 38(1):207-11. PubMed ID: 9212025
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer.
    Pos FJ; Horenblas S; Lebesque J; Moonen L; Schneider C; Sminia P; Bartelink H
    Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):696-705. PubMed ID: 15183473
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparison of 3D dose distributions for HDR 192Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system.
    Senkesen O; Tezcanli E; Buyuksarac B; Ozbay I
    Med Dosim; 2014; 39(3):266-71. PubMed ID: 24933316
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources.
    Ferreira IH; de Almeida CE; Marre D; Marechal MH; Bridier A; Chavaudra J
    Phys Med Biol; 1999 Aug; 44(8):1897-904. PubMed ID: 10473203
    [TBL] [Abstract][Full Text] [Related]  

  • 57. High versus low dose rate intracavitary irradiation for adenocarcinoma of the uterine cervix.
    Kim WC; Kim GE; Suh CO; Loh JJ
    Jpn J Clin Oncol; 2001 Sep; 31(9):432-7. PubMed ID: 11689597
    [TBL] [Abstract][Full Text] [Related]  

  • 58. From low-dose-rate to high-dose-rate brachytherapy in lip carcinoma: Equivalent results but fewer complications.
    Guinot JL; Arribas L; Tortajada MI; Crispín V; Carrascosa M; Santos M; Mut A; Vendrell JB; Pesudo C; Chust ML
    Brachytherapy; 2013; 12(6):528-34. PubMed ID: 23850275
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Modelling second malignancy risks from low dose rate and high dose rate brachytherapy as monotherapy for localised prostate cancer.
    Murray L; Mason J; Henry AM; Hoskin P; Siebert FA; Venselaar J; Bownes P;
    Radiother Oncol; 2016 Aug; 120(2):293-9. PubMed ID: 27370205
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors.
    Qi ZY; Deng XW; Huang SM; Lu J; Lerch M; Cutajar D; Rosenfeld A
    Med Phys; 2007 Jun; 34(6):2007-13. PubMed ID: 17654904
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.