These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
181 related articles for article (PubMed ID: 7799630)
1. The effect of wall distensibility on flow in a two-dimensional end-to-side anastomosis. Steinman DA; Ethier CR J Biomech Eng; 1994 Aug; 116(3):294-301. PubMed ID: 7799630 [TBL] [Abstract][Full Text] [Related]
2. A numerical simulation of flow in a two-dimensional end-to-side anastomosis model. Steinman DA; Vinh B; Ethier CR; Ojha M; Cobbold RS; Johnston KW J Biomech Eng; 1993 Feb; 115(1):112-8. PubMed ID: 8445888 [TBL] [Abstract][Full Text] [Related]
4. Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis. Lei M; Archie JP; Kleinstreuer C J Vasc Surg; 1997 Apr; 25(4):637-46. PubMed ID: 9129618 [TBL] [Abstract][Full Text] [Related]
5. Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia. Hofer M; Rappitsch G; Perktold K; Trubel W; Schima H J Biomech; 1996 Oct; 29(10):1297-308. PubMed ID: 8884475 [TBL] [Abstract][Full Text] [Related]
6. The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. Fei DY; Thomas JD; Rittgers SE J Biomech Eng; 1994 Aug; 116(3):331-6. PubMed ID: 7799636 [TBL] [Abstract][Full Text] [Related]
7. [Influences of graft diameter on the blood flow in 2-way bypassing surgery]. Qiao A; Liu Y; Zhang S Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):346-50, 377. PubMed ID: 18610620 [TBL] [Abstract][Full Text] [Related]
8. Computational investigations of a new prosthetic femoral-popliteal bypass graft design. O'Brien TP; Grace P; Walsh M; Burke P; McGloughlin T J Vasc Surg; 2005 Dec; 42(6):1169-75. PubMed ID: 16376210 [TBL] [Abstract][Full Text] [Related]
9. Is there a haemodynamic advantage associated with cuffed arterial anastomoses? Cole JS; Watterson JK; O'Reilly MJ J Biomech; 2002 Oct; 35(10):1337-46. PubMed ID: 12231279 [TBL] [Abstract][Full Text] [Related]
10. Flow dynamics across end-to-end vascular bypass graft anastomoses. Kim YH; Chandran KB; Bower TJ; Corson JD Ann Biomed Eng; 1993; 21(4):311-20. PubMed ID: 8214816 [TBL] [Abstract][Full Text] [Related]
11. Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis. Weston MW; Rhee K; Tarbell JM J Biomech; 1996 Feb; 29(2):187-98. PubMed ID: 8849812 [TBL] [Abstract][Full Text] [Related]
12. Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model. Ojha M J Biomech; 1993 Dec; 26(12):1377-88. PubMed ID: 8308043 [TBL] [Abstract][Full Text] [Related]
14. Compliant model of a coupled sequential coronary arterial bypass graft: effects of vessel wall elasticity and non-Newtonian rheology on blood flow regime and hemodynamic parameters distribution. Kabinejadian F; Ghista DN Med Eng Phys; 2012 Sep; 34(7):860-72. PubMed ID: 22032834 [TBL] [Abstract][Full Text] [Related]
15. Fluid dynamics, wall mechanics, and oxygen transfer in peripheral bypass anastomoses. Perktold K; Leuprecht A; Prosi M; Berk T; Czerny M; Trubel W; Schima H Ann Biomed Eng; 2002 Apr; 30(4):447-60. PubMed ID: 12085997 [TBL] [Abstract][Full Text] [Related]
16. Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses. Loth F; Jones SA; Zarins CK; Giddens DP; Nassar RF; Glagov S; Bassiouny HS J Biomech Eng; 2002 Feb; 124(1):44-51. PubMed ID: 11871604 [TBL] [Abstract][Full Text] [Related]
17. Numerical simulation of wall shear stress and particle-based hemodynamic parameters in pre-cuffed and streamlined end-to-side anastomoses. Longest PW; Kleinstreuer C; Deanda A Ann Biomed Eng; 2005 Dec; 33(12):1752-66. PubMed ID: 16389524 [TBL] [Abstract][Full Text] [Related]
18. Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts. Leuprecht A; Perktold K; Prosi M; Berk T; Trubel W; Schima H J Biomech; 2002 Feb; 35(2):225-36. PubMed ID: 11784541 [TBL] [Abstract][Full Text] [Related]
19. Wall shear stresses in small and large two-way bypass grafts. Qiao A; Liu Y; Guo Z Med Eng Phys; 2006 Apr; 28(3):251-8. PubMed ID: 16029954 [TBL] [Abstract][Full Text] [Related]
20. Flow patterns and preferred sites of intimal thickening in bypass-grafted arteries . Sunamura M; Ishibashi H; Karino T Int Angiol; 2012 Apr; 31(2):187-97. PubMed ID: 22466986 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]