These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 7802369)

  • 1. End-tidal carbon dioxide during out-of-hospital cardiac arrest resuscitation: comparison of active compression-decompression and standard CPR.
    Orliaguet GA; Carli PA; Rozenberg A; Janniere D; Sauval P; Delpech P
    Ann Emerg Med; 1995 Jan; 25(1):48-51. PubMed ID: 7802369
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Active compression-decompression. A new method of cardiopulmonary resuscitation. Cardiopulmonary Resuscitation Working Group.
    Cohen TJ; Tucker KJ; Lurie KG; Redberg RF; Dutton JP; Dwyer KA; Schwab TM; Chin MC; Gelb AM; Scheinman MM
    JAMA; 1992 Jun; 267(21):2916-23. PubMed ID: 1583761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest.
    Plaisance P; Lurie KG; Payen D
    Circulation; 2000 Mar; 101(9):989-94. PubMed ID: 10704165
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A randomized clinical trial of active compression-decompression CPR vs standard CPR in out-of-hospital cardiac arrest in two cities.
    Schwab TM; Callaham ML; Madsen CD; Utecht TA
    JAMA; 1995 Apr; 273(16):1261-8. PubMed ID: 7715038
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of active compression-decompression CPR in victims of out-of-hospital cardiac arrest.
    Lurie KG; Shultz JJ; Callaham ML; Schwab TM; Gisch T; Rector T; Frascone RJ; Long L
    JAMA; 1994 May; 271(18):1405-11. PubMed ID: 8176802
    [TBL] [Abstract][Full Text] [Related]  

  • 6. End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study.
    Setälä PA; Virkkunen IT; Kämäräinen AJ; Huhtala HSA; Virta JS; Yli-Hankala AM; Hoppu SE
    Emerg Med J; 2018 Jul; 35(7):428-432. PubMed ID: 29769232
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest.
    Wolcke BB; Mauer DK; Schoefmann MF; Teichmann H; Provo TA; Lindner KH; Dick WF; Aeppli D; Lurie KG
    Circulation; 2003 Nov; 108(18):2201-5. PubMed ID: 14568898
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (P(ET)CO2) during CPR in out-of-hospital cardiac arrest (OHCA).
    Axelsson C; Karlsson T; Axelsson AB; Herlitz J
    Resuscitation; 2009 Oct; 80(10):1099-103. PubMed ID: 19716640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemodynamic effects of active compression-decompression after prolonged CPR.
    Malzer R; Zeiner A; Binder M; Domanovits H; Knappitsch G; Sterz F; Laggner AN
    Resuscitation; 1996 Jun; 31(3):243-53. PubMed ID: 8783410
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Association between Prehospital CPR Quality and End-Tidal Carbon Dioxide Levels in Out-of-Hospital Cardiac Arrest.
    Murphy RA; Bobrow BJ; Spaite DW; Hu C; McDannold R; Vadeboncoeur TF
    Prehosp Emerg Care; 2016; 20(3):369-77. PubMed ID: 26830353
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Comparison of the Effect of Interposed Abdominal Compression Cardiopulmonary Resuscitation and Standard Cardiopulmonary Resuscitation Methods on End-tidal CO2 and the Return of Spontaneous Circulation Following Cardiac Arrest: A Clinical Trial.
    Movahedi A; Mirhafez SR; Behnam-Voshani H; Reihani H; Kavosi A; Ferns GA; Malekzadeh J
    Acad Emerg Med; 2016 Apr; 23(4):448-54. PubMed ID: 26801358
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of active compression-decompression resuscitation on myocardial and cerebral blood flow in pigs.
    Lindner KH; Pfenninger EG; Lurie KG; Schürmann W; Lindner IM; Ahnefeld FW
    Circulation; 1993 Sep; 88(3):1254-63. PubMed ID: 8353887
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of end tidal carbon dioxide, amplitude spectrum area, and coronary perfusion pressure in a porcine model of cardiac arrest.
    Segal N; Metzger AK; Moore JC; India L; Lick MC; Berger PS; Tang W; Benditt DG; Lurie KG
    Physiol Rep; 2017 Sep; 5(17):. PubMed ID: 28899911
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The United Kingdom pre-hospital study of active compression-decompression resuscitation.
    Nolan J; Smith G; Evans R; McCusker K; Lubas P; Parr M; Baskett P
    Resuscitation; 1998 May; 37(2):119-25. PubMed ID: 9671087
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effectiveness of mechanical versus manual chest compressions in out-of-hospital cardiac arrest resuscitation: a pilot study.
    Dickinson ET; Verdile VP; Schneider RM; Salluzzo RF
    Am J Emerg Med; 1998 May; 16(3):289-92. PubMed ID: 9596436
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of standard cardiopulmonary resuscitation and active compression-decompression resuscitation for out-of-hospital cardiac arrest. French Active Compression-Decompression Cardiopulmonary Resuscitation Study Group.
    Plaisance P; Lurie KG; Vicaut E; Adnet F; Petit JL; Epain D; Ecollan P; Gruat R; Cavagna P; Biens J; Payen D
    N Engl J Med; 1999 Aug; 341(8):569-75. PubMed ID: 10451462
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Carbon dioxide levels during pre-hospital active compression--decompression versus standard cardiopulmonary resuscitation.
    Mauer D; Schneider T; Elich D; Dick W
    Resuscitation; 1998; 39(1-2):67-74. PubMed ID: 9918450
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Active compression-decompression cardiopulmonary resuscitation does not improve survival in patients with prehospital cardiac arrest in a physician-manned emergency medical system.
    Luiz T; Ellinger K; Denz C
    J Cardiothorac Vasc Anesth; 1996 Feb; 10(2):178-86. PubMed ID: 8850394
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Associations Between End-Tidal Carbon Dioxide During Pediatric Cardiopulmonary Resuscitation, Cardiopulmonary Resuscitation Quality, and Survival.
    Morgan RW; Reeder RW; Bender D; Cooper KK; Friess SH; Graham K; Meert KL; Mourani PM; Murray R; Nadkarni VM; Nataraj C; Palmer CA; Srivastava N; Tilford B; Wolfe HA; Yates AR; Berg RA; Sutton RM;
    Circulation; 2024 Jan; 149(5):367-378. PubMed ID: 37929615
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Random control trial of the efficacy of cardio pump on pre-hospital cardiac arrest].
    He Q; Wan Z; Wang L
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2003 May; 15(5):292-4. PubMed ID: 12837190
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.