These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 7802874)

  • 1. Strain gauged six-component load transducer for use in upper limb biomechanics.
    Runciman RJ; Nicol AC
    Proc Inst Mech Eng H; 1993; 207(4):231-7. PubMed ID: 7802874
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A force transducer to measure individual finger loads during activities of daily living.
    Fowler NK; Nicol AC
    J Biomech; 1999 Jul; 32(7):721-5. PubMed ID: 10400360
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel instrumented ring for the measurement of grip force adjustments during precision grip tasks.
    van der Kamp M; Conway BA; Nicol AC
    Proc Inst Mech Eng H; 2001; 215(4):421-7. PubMed ID: 11521765
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel force transducer for the measurement of grip force.
    Chadwick EK; Nicol AC
    J Biomech; 2001 Jan; 34(1):125-8. PubMed ID: 11425072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A palmar pressure sensor for measurement of upper limb weight bearing by the hands during transfers by paraplegics.
    Kunju N; Ojha R; Devasahayam SR
    J Med Eng Technol; 2013 Oct; 37(7):424-8. PubMed ID: 23964668
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stress distributions inside intervertebral discs: the validity of experimental "stress profilometry'.
    McMillan DW; McNally DS; Garbutt G; Adams MA
    Proc Inst Mech Eng H; 1996; 210(2):81-7. PubMed ID: 8688120
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design, calibration and pre-clinical testing of an instrumented tibial tray.
    Heinlein B; Graichen F; Bender A; Rohlmann A; Bergmann G
    J Biomech; 2007; 40 Suppl 1():S4-10. PubMed ID: 17433815
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies.
    Ravary B; Pourcelot P; Bortolussi C; Konieczka S; Crevier-Denoix N
    Clin Biomech (Bristol); 2004 Jun; 19(5):433-47. PubMed ID: 15182978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In situ calibration of miniature sensors implanted into the anterior cruciate ligament part I: strain measurements.
    Markolf KL; Willems MJ; Jackson SR; Finerman GA
    J Orthop Res; 1998 Jul; 16(4):455-63. PubMed ID: 9747787
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can compressive stress be measured experimentally within the annulus fibrosus of degenerated intervertebral discs?
    Chu JY; Skrzypiec D; Pollintine P; Adams MA
    Proc Inst Mech Eng H; 2008 Feb; 222(2):161-70. PubMed ID: 18441752
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine.
    Wilson DC; Niosi CA; Zhu QA; Oxland TR; Wilson DR
    J Biomech; 2006; 39(2):348-53. PubMed ID: 16321637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A biologic model for assessment of osseous strain patterns and plating systems in the human maxilla.
    Alberts LR; Phillips KO; Tu HK; Stinson WW; Friedman A
    J Oral Maxillofac Surg; 2003 Jan; 61(1):79-88. PubMed ID: 12524613
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calculation of tibial loading using strain gauges.
    Funk JR; Crandall JR
    Biomed Sci Instrum; 2006; 42():160-5. PubMed ID: 16817602
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design and validation of a novel Cartesian biomechanical testing system with coordinated 6DOF real-time load control: application to the lumbar spine (L1-S, L4-L5).
    Kelly BP; Bennett CR
    J Biomech; 2013 Jul; 46(11):1948-54. PubMed ID: 23764173
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A method for measuring vertical forces applied to the upper limb during sit-to-stand.
    Turner HC; Yate RM; Giddins GE; Miles AW
    Proc Inst Mech Eng H; 2004; 218(6):461-5. PubMed ID: 15648670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization and application of thin film pressure sensors.
    Valdevit A; Ortega-Garcia J; Kambic H; Kuroda R; Elster T; Parker RD
    Biomed Mater Eng; 1999; 9(2):81-8. PubMed ID: 10524291
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Contact transducer for continuous measurement of blood vessel diameter].
    Rogoza AN
    Biull Eksp Biol Med; 1981 May; 91(5):626-8. PubMed ID: 7260397
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An implantable telemetry device to measure intra-articular tibial forces.
    D'Lima DD; Townsend CP; Arms SW; Morris BA; Colwell CW
    J Biomech; 2005 Feb; 38(2):299-304. PubMed ID: 15598457
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Some problems in using a polyvinylidene fluoride transducer for the intra-articular determination of joint contact stress.
    Hale JE; Vaughan CL
    Proc Inst Mech Eng H; 1993; 207(2):127-31. PubMed ID: 8280314
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of push/pull force estimates using a single-axis gauge versus a three-dimensional hand transducer.
    Weston EB; Marras WS
    Appl Ergon; 2020 Oct; 88():103184. PubMed ID: 32678789
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.