These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 7803755)

  • 1. Incorrectly labelled double-lumen tube.
    Fikkers BG; Zandstra DF
    J Cardiothorac Vasc Anesth; 1994 Oct; 8(5):605. PubMed ID: 7803755
    [No Abstract]   [Full Text] [Related]  

  • 2. An unusual cause of high airway pressure and inadequate ventilation because of a defective connector despite accurate placement of a double-lumen tube.
    Koshy T; Sinha PK; Vijayakumar A; Dash PK; Unnikrishnan KP
    J Cardiothorac Vasc Anesth; 2006 Aug; 20(4):627-30. PubMed ID: 16885003
    [No Abstract]   [Full Text] [Related]  

  • 3. Ventilation failure resulting from defective double-lumen endobronchial tube.
    Irie T; Kurahashi K; Ogawa K; Furuya R; Yamada Y
    Anesth Analg; 2005 Jun; 100(6):1866. PubMed ID: 15920246
    [No Abstract]   [Full Text] [Related]  

  • 4. Response: complaint on Mallinckrodt broncho-cath endobronchial tube.
    J Cardiothorac Vasc Anesth; 1994 Oct; 8(5):605-6. PubMed ID: 7803756
    [No Abstract]   [Full Text] [Related]  

  • 5. A new technique for replacing an endobronchial double-lumen tube with an endotracheal single-lumen tube.
    Gatell JA; Barst SM; Desiderio DP; Kolker AC; Scher CS
    Anesthesiology; 1990 Aug; 73(2):340-1. PubMed ID: 2382856
    [No Abstract]   [Full Text] [Related]  

  • 6. Cable trapped under Dräger Fabius automatic pressure limiting valve causes inability to ventilate.
    Kibelbek MJ
    Anesthesiology; 2007 Mar; 106(3):639-40; author reply 640. PubMed ID: 17325535
    [No Abstract]   [Full Text] [Related]  

  • 7. Sudden loss of ventilation through a double-lumen endotracheal tube requiring a surgical bronchotomy.
    Torrance R; Dawson A; Wohlgemut JM; Buchan K
    Ann Thorac Surg; 2013 Aug; 96(2):687-8. PubMed ID: 23910113
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Placement of a Double-Lumen Endotracheal Tube.
    Hao D; Saddawi-Konefka D; Low S; Alfille P; Baker K
    N Engl J Med; 2021 Oct; 385(16):e52. PubMed ID: 34644474
    [No Abstract]   [Full Text] [Related]  

  • 9. The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures.
    Lewis JW; Serwin JP; Gabriel FS; Bastanfar M; Jacobsen G
    J Cardiothorac Vasc Anesth; 1992 Dec; 6(6):705-10. PubMed ID: 1472668
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endotracheal tube holders and the prone position: a cause for concern.
    Gomaa D; Branson RD
    Respir Care; 2015 Feb; 60(2):e41-2. PubMed ID: 25634884
    [No Abstract]   [Full Text] [Related]  

  • 11. What to do when an endotracheal tube cuff leaks.
    Ho AM; Contardi LH
    J Trauma; 1996 Mar; 40(3):486-7. PubMed ID: 8601877
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endotracheal tube holders and the prone position: a cause for concern--reply.
    Fisher DF; Kacmarek RM
    Respir Care; 2015 Feb; 60(2):e42. PubMed ID: 25634885
    [No Abstract]   [Full Text] [Related]  

  • 13. The Combitube oesophageal-tracheal double lumen airway for difficult intubation.
    Baraka A; Salem R
    Can J Anaesth; 1993 Dec; 40(12):1222-3. PubMed ID: 8281605
    [No Abstract]   [Full Text] [Related]  

  • 14. Choosing the appropriate double-lumen tube: a glimmer of science comes to a dark art.
    Slinger P
    J Cardiothorac Vasc Anesth; 1995 Apr; 9(2):117-8. PubMed ID: 7780064
    [No Abstract]   [Full Text] [Related]  

  • 15. Capnography does not reliably detect double-lumen endotracheal tube malplacement.
    de Vries JW; Haanschoten MC
    J Clin Monit; 1992 Jul; 8(3):236-7. PubMed ID: 1494931
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Alcohol increases bonding between the tracheal tube and the tracheal tube connector.
    Mullick P; Kumar A; Prakash S
    A A Case Rep; 2015 May; 4(9):114-6. PubMed ID: 25909775
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of a positive end-expiratory pressure adapter on oxygenation during endotracheal suctioning.
    Douglas S; Larson EL
    Heart Lung; 1985 Jul; 14(4):396-400. PubMed ID: 3891690
    [No Abstract]   [Full Text] [Related]  

  • 18. Failed ventilation due to breakage of a tracheal tube connector.
    Asai T; Johmura S; Shingu K
    Anaesthesia; 2000 Sep; 55(9):915-6. PubMed ID: 10947764
    [No Abstract]   [Full Text] [Related]  

  • 19. New endotracheal tube (Univent tube) for selective blockade of one lung.
    Kamaya H; Krishna PR
    Anesthesiology; 1985 Sep; 63(3):342-3. PubMed ID: 4025905
    [No Abstract]   [Full Text] [Related]  

  • 20. [Connector for double-lumen tubes in thoracic surgery interventions].
    Klein U; Knebel F; Gottschall R
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1993 Nov; 28(7):467-9. PubMed ID: 8297957
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.