BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 7803774)

  • 1. [Evaluation of rapid gradient-echo and turbo-spin-echo sequences in MRT of focal liver lesions using 0.5 tesla].
    Kreft B; Layer G; Spiller L; Träber F; Wolff M; Gieseke J; Steudel A
    Rofo; 1994 Dec; 161(6):512-8. PubMed ID: 7803774
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Comparison of fast turbo-spin-echo and gradient- and spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla].
    Jung G; Krahe T; Kugel H; Gieseke J; Walter C; Fischbach R; Landwehr P
    Rofo; 1996 Aug; 165(2):137-43. PubMed ID: 8924665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Turbo-spin-echo sequences with selective fat suppression (SPIR) in the MRI of focal liver lesions at 0.5 tesla].
    Kreft B; Layer G; Kuhl C; Sommer T; Gieseke J; Schild H
    Rofo; 1995 Nov; 163(5):411-6. PubMed ID: 8527755
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [MRI of focal liver lesions using a 1.5 turbo-spin-echo technique compared with spin-echo technique].
    Steiner S; Vogl TJ; Fischer P; Steger W; Neuhaus P; Keck H
    Rofo; 1995 Aug; 163(2):141-7. PubMed ID: 7670015
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Phased-array superficial coil and breath holding technique in MRI of the liver. Comparison of conventional spin echo sequences with rapid fat suppressing gradient echo and turbo-spin sequences].
    Helmberger T; Holzknecht N; Lackerbauer CA; Müller-Lisse U; Schnarkowski P; Gauger J; Reiser M
    Radiologe; 1995 Dec; 35(12):919-24. PubMed ID: 8584635
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Focal liver lesions: characterization with quantitative analysis of T2 relaxation time in TSE sequence with double echo time.
    Cittadini G; Santacroce E; Giasotto V; Rescinito G
    Radiol Med; 2004 Mar; 107(3):166-73. PubMed ID: 15031682
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Comparison of three-dimensional gradient echo, turbo spin echo and steady-state gradient echo sequences in axial MRI examination of the cervical spine].
    Mahmutyazicioğlu K; Ozdemir H; Savranlar A; Ozer T; Erdem O; Erdem Z; Gündoğdu S
    Tani Girisim Radyol; 2003 Dec; 9(4):432-8. PubMed ID: 14730951
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.
    Hussain SM; De Becker J; Hop WC; Dwarkasing S; Wielopolski PA
    J Magn Reson Imaging; 2005 Mar; 21(3):219-29. PubMed ID: 15723376
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of respiratory-triggered T2-weighted turbo spin-echo imaging versus breath-hold T2-weighted turbo spin-echo imaging: distinguishing benign from malignant liver lesions in patients with colorectal cancer.
    Coenegrachts K; ter Beek L; Haspeslagh M; Bipat S; Stoker J; Rigauts H
    JBR-BTR; 2009; 92(4):195-201. PubMed ID: 19803097
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences].
    Czerny C; Trattnig S; Baumgartner WD; Gstöttner W; Imhof H
    Rofo; 1997 Oct; 167(4):377-83. PubMed ID: 9417266
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Conspicuity of liver hemangiomas: short tau inversion recovery, T1, and T2 imaging with gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid.
    Brody JM; Schafer L; Tung GA; Breuer J; Shamsi K
    J Magn Reson Imaging; 2005 Apr; 21(4):391-7. PubMed ID: 15778951
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: a prospective comparative study.
    Yamashita Y; Yamamoto H; Namimoto T; Abe Y; Takahashi M
    J Magn Reson Imaging; 1997; 7(2):292-7. PubMed ID: 9090580
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Nuclear magnetic resonance tomography of the liver with Turbo FLASH].
    Wallner B; Edelman RR; Mattle HP
    Digitale Bilddiagn; 1990; 10(3-4):86-91. PubMed ID: 1964884
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors: comparison of echo-planar, HASTE, and spin-echo sequences.
    Abe Y; Yamashita Y; Tang Y; Namimoto T; Takahashi M
    Radiat Med; 2000; 18(1):7-14. PubMed ID: 10852650
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hepatic malignant tumour versus cavernous haemangioma: differentiation on multiple breath-hold turbo spin-echo MRI sequences with different T2-weighting and T2-relaxation time measurements on a single slice multi-echo sequence.
    Chan YL; Lee SF; Yu SC; Lai P; Ching AS
    Clin Radiol; 2002 Apr; 57(4):250-7. PubMed ID: 12014868
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Post-operative lumbar spine: comparative study of TSE T2 and turbo-FLAIR sequences vs contrast-enhanced SE T1.
    Barrera MC; Alústiza JM; Gervás C; Recondo JA; Villanúa JA; Salvador E
    Clin Radiol; 2001 Feb; 56(2):133-7. PubMed ID: 11222072
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Value of turbo-spin-echo sequences in cerebral magnetic resonance tomography in children].
    Kreft B; Kuhl C; Keller E; Schömer M; Haghir-Schömer M; Gieseke J; Haverkamp F; Schild H
    Rofo; 1995 Aug; 163(2):134-40. PubMed ID: 7670014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Parametrial infiltration of cervix carcinoma: diagnostic value of contrast-enhanced fat-suppressed T1-weighted SE sequences at 1.5 tesla].
    Scheidler J; Heuck A; Wencke K; Kimmig R; Müller-Lisse U; Reiser M
    Rofo; 1997 Apr; 166(4):312-6. PubMed ID: 9198495
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Hepatic and hepatocarcinoma magnetic resonance: comparison of the results obtained with paramagnetic (gadolinium) and superparamagnetic (iron oxide particles) contrast media].
    Castoldi MC; Fauda V; Scaramuzza D; Vergnaghi D
    Radiol Med; 2000 Sep; 100(3):160-7. PubMed ID: 11148882
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Differentiation of hepatocellular carcinoma and hepatic metastasis from cysts and hemangiomas with calculated T2 relaxation times and the T1/T2 relaxation times ratio.
    Farraher SW; Jara H; Chang KJ; Ozonoff A; Soto JA
    J Magn Reson Imaging; 2006 Dec; 24(6):1333-41. PubMed ID: 17083093
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.