These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 7807614)

  • 1. [How should high concentration oxygen be provided with a resuscitator during resuscitation?].
    Huang YC; Chang CF; Ker CG
    Gaoxiong Yi Xue Ke Xue Za Zhi; 1994 Oct; 10(10):578-82. PubMed ID: 7807614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The changes in delivered oxygen fractions using laerdal resuscitator bag with different types of reservoir.
    Nam SH; Kim KJ; Nam YT; Shim JK
    Yonsei Med J; 2001 Apr; 42(2):242-6. PubMed ID: 11371114
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of three neonatal resuscitation devices.
    Bennett S; Finer NN; Rich W; Vaucher Y
    Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A simple method to increase the FDO2 of resuscitator bags.
    Priano LL; Ham J
    Crit Care Med; 1978; 6(1):48-9. PubMed ID: 273497
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir.
    Thió M; Bhatia R; Dawson JA; Davis PG
    Arch Dis Child Fetal Neonatal Ed; 2010 Sep; 95(5):F315-9. PubMed ID: 19843501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The self-inflating resuscitation bag delivers high oxygen concentrations when used without a reservoir: implications for neonatal resuscitation.
    Johnston KL; Aziz K
    Respir Care; 2009 Dec; 54(12):1665-70. PubMed ID: 19961632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Laerdal infant resuscitators are unreliable as free-flow oxygen delivery devices.
    Martell RJ; Soder CM
    Am J Perinatol; 1997 Jul; 14(6):347-51. PubMed ID: 9217956
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the FiO2 delivered by seven models of the self-inflating bag-mask system.
    de Godoy AC; Vieira RJ
    Rev Bras Anestesiol; 2009; 59(1):21-7. PubMed ID: 19374212
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Delivery of titrated oxygen via a self-inflating resuscitation bag.
    Young P; Pilcher J; Patel M; Cameron L; Braithwaite I; Weatherall M; Beasley R
    Resuscitation; 2013 Mar; 84(3):391-4. PubMed ID: 22955052
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
    Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
    Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Oxygen concentrations at the rear and front of the bag in bag valve mask devices during oxygenation of neonates.
    Bakr AF; El-Attar A
    Resuscitation; 2005 Aug; 66(2):217-23. PubMed ID: 16053945
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of 16 adult disposable manual resuscitators.
    Mazzolini DG; Marshall NA
    Respir Care; 2004 Dec; 49(12):1509-14. PubMed ID: 15571642
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of the Laerdal infant resuscitator results in the delivery of high oxygen fractions in the absence of a blender.
    Reise K; Monkman S; Kirpalani H
    Resuscitation; 2009 Jan; 80(1):120-5. PubMed ID: 18952345
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Occupational burns from oxygen resuscitator fires: the hazard of aluminum regulators.
    Hodous TK; Washenitz F; Newton B
    Am J Ind Med; 2002 Jul; 42(1):63-9. PubMed ID: 12111692
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The mouth-to-bag resuscitator during standard anaesthesia induction in apnoeic patients.
    Herff H; Paal P; Mitterlechner T; von Goedecke A; Stadlbauer KH; Voelckel WG; Zecha-Stallinger A; Wenzel V
    Resuscitation; 2009 Oct; 80(10):1142-6. PubMed ID: 19674827
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sustained airway pressure after transient occlusion of a valve venting a self-inflating manual resuscitator.
    Lien S; Verreault DJ; Alston TA
    J Clin Anesth; 2013 Aug; 25(5):424-425. PubMed ID: 23965202
    [No Abstract]   [Full Text] [Related]  

  • 17. Providing PEEP during neonatal resuscitation: which device is best?
    Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
    J Paediatr Child Health; 2011 Oct; 47(10):698-703. PubMed ID: 21449898
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Oxygen concentrations from self-inflating resuscitation bags.
    Hermansen MC; Prior MM
    Am J Perinatol; 1993 Jan; 10(1):79-80. PubMed ID: 8442809
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Combibag: an evaluation of a new self-inflating resuscitator.
    Cramond T; O'Callaghan JP
    Anaesth Intensive Care; 1986 Feb; 14(1):66-9. PubMed ID: 3954016
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the T-piece resuscitator with other neonatal manual ventilation devices: a qualitative review.
    Hawkes CP; Ryan CA; Dempsey EM
    Resuscitation; 2012 Jul; 83(7):797-802. PubMed ID: 22227500
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.