BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 7817826)

  • 1. Dual x-ray absorptiometry forearm software: accuracy and intermachine relationship.
    Hagiwara S; Engelke K; Yang SO; Dhillon MS; Guglielmi G; Nelson DL; Genant HK
    J Bone Miner Res; 1994 Sep; 9(9):1425-7. PubMed ID: 7817826
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results.
    Genant HK; Grampp S; Glüer CC; Faulkner KG; Jergas M; Engelke K; Hagiwara S; Van Kuijk C
    J Bone Miner Res; 1994 Oct; 9(10):1503-14. PubMed ID: 7817795
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anomalies in the measurement of changes in total-body bone mineral by dual-energy X-ray absorptiometry during weight change.
    Tothill P; Hannan WJ; Cowen S; Freeman CP
    J Bone Miner Res; 1997 Nov; 12(11):1908-21. PubMed ID: 9383696
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Precision and accuracy of a transportable dual-energy X-ray absorptiometry unit for bone mineral measurements in guinea pigs.
    Fink C; Cooper HJ; Huebner JL; Guilak F; Kraus VB
    Calcif Tissue Int; 2002 Mar; 70(3):164-9. PubMed ID: 11907713
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technical considerations of dual-energy X-ray absorptiometry-based bone mineral measurements for pediatric studies.
    Koo WW; Walters J; Bush AJ
    J Bone Miner Res; 1995 Dec; 10(12):1998-2004. PubMed ID: 8619381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cross calibration of Hologic QDR2000 and GE Lunar Prodigy for forearm bone mineral density measurements.
    Pearson D; Horton B; Green DJ
    J Clin Densitom; 2007; 10(3):306-11. PubMed ID: 17584510
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Manufacture and evaluation of a spine phantom used in the cross-calibration of DXA bone densitometry].
    Yang DZ; Shang JY; Song WZ; Chen J; Zhu D; Wang WZ
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2003 Jun; 25(3):262-6. PubMed ID: 12905736
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip, and forearm: a human cadaver study.
    Svendsen OL; Hassager C; Skødt V; Christiansen C
    J Bone Miner Res; 1995 Jun; 10(6):868-73. PubMed ID: 7572310
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of rates of bone loss from the spine measured using two manufacturers' densitometers.
    Peel NF; Eastell R
    J Bone Miner Res; 1995 Nov; 10(11):1796-801. PubMed ID: 8592958
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dual-energy x-ray absorptiometry of the forearm: reproducibility and correlation with single-photon absorptiometry.
    Leboff MS; Fuleihan GE; Angell JE; Chung S; Curtis K
    J Bone Miner Res; 1992 Jul; 7(7):841-6. PubMed ID: 1642152
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of body composition by dual energy x-ray absorptiometry and two different software packages.
    Van Loan MD; Keim NL; Berg K; Mayclin PL
    Med Sci Sports Exerc; 1995 Apr; 27(4):587-91. PubMed ID: 7791591
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems.
    Shepherd JA; Fan B; Lu Y; Wu XP; Wacker WK; Ergun DL; Levine MA
    J Bone Miner Res; 2012 Oct; 27(10):2208-16. PubMed ID: 22623101
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simulated change in body fatness affects Hologic QDR 4500A whole body and central DXA bone measures.
    Evans EM; Mojtahedi MC; Kessinger RB; Misic MM
    J Clin Densitom; 2006; 9(3):315-22. PubMed ID: 16931350
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correcting the magnification error of fan beam densitometers.
    Griffiths MR; Noakes KA; Pocock NA
    J Bone Miner Res; 1997 Jan; 12(1):119-23. PubMed ID: 9240734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prediction of bone mineral density of lumbar spine, hip, femoral neck and Ward's triangle by forearm bone mineral density.
    Trivitayaratana W; Trivitayaratana P; Kongkiatikul S
    J Med Assoc Thai; 2001 Mar; 84(3):390-6. PubMed ID: 11460941
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of accuracy and precision of dual energy X-ray absorptiometry for infants.
    Koo WW; Massom LR; Walters J
    J Bone Miner Res; 1995 Jul; 10(7):1111-5. PubMed ID: 7484287
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calibration of dual-energy x-ray absorptiometry for bone density.
    Mazess RB; Trempe JA; Bisek JP; Hanson JA; Hans D
    J Bone Miner Res; 1991 Aug; 6(8):799-806. PubMed ID: 1785372
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Universal standardization of bone density measurements: a method with optimal properties for calibration among several instruments.
    Hui SL; Gao S; Zhou XH; Johnston CC; Lu Y; Glüer CC; Grampp S; Genant H
    J Bone Miner Res; 1997 Sep; 12(9):1463-70. PubMed ID: 9286763
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments.
    Tothill P; Laskey MA; Orphanidou CI; van Wijk M
    Br J Radiol; 1999 Jul; 72(859):661-9. PubMed ID: 10624323
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Can forearm bone mineral density be measured with dxa in the supine position? A study in Chinese population.
    Zhao J; Xing Y; Zhou Q; Jin W; Wacker W; Barden HS
    J Clin Densitom; 2010; 13(2):147-50. PubMed ID: 20435265
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.