These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 7818045)
1. [Continuous intravascular blood gas analysis. Clinical evaluation of a new fiber optic monitor]. Haller M; Kilger E; Briegel J; Polasek J; Forst H; Groh J; Peter K Anaesthesist; 1994 Oct; 43(10):642-7. PubMed ID: 7818045 [TBL] [Abstract][Full Text] [Related]
2. Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: a prospective, criterion standard study. Haller M; Kilger E; Briegel J; Forst H; Peter K Crit Care Med; 1994 Apr; 22(4):580-7. PubMed ID: 8143467 [TBL] [Abstract][Full Text] [Related]
3. Long-term evaluation of a continuous intra-arterial blood gas monitoring system in patients with severe respiratory failure. Kilger E; Briegel J; Schelling G; Polasek J; Manert W; Groh J; Haller M Infusionsther Transfusionsmed; 1995 Apr; 22(2):98-104. PubMed ID: 7787410 [TBL] [Abstract][Full Text] [Related]
4. Multisite evaluation of a continuous intraarterial blood gas monitoring system. Larson CP; Vender J; Seiver A Anesthesiology; 1994 Sep; 81(3):543-52. PubMed ID: 8092498 [TBL] [Abstract][Full Text] [Related]
5. Clinical assessment of a continuous intraarterial blood gas monitoring system. Uchida T; Makita K; Tsunoda Y; Toyooka H; Amaha K Can J Anaesth; 1994 Jan; 41(1):64-70. PubMed ID: 8111948 [TBL] [Abstract][Full Text] [Related]
6. A multiparameter sensor for continuous intra-arterial blood gas monitoring: a prospective evaluation. Venkatesh B; Clutton Brock TH; Hendry SP Crit Care Med; 1994 Apr; 22(4):588-94. PubMed ID: 8143468 [TBL] [Abstract][Full Text] [Related]
7. Initial evaluation of a new intra-arterial blood gas system in humans. Zimmerman JL; Dellinger RP Crit Care Med; 1993 Apr; 21(4):495-500. PubMed ID: 8472566 [TBL] [Abstract][Full Text] [Related]
8. Experiences with continuous intra-arterial blood gas monitoring. Menzel M; Henze D; Soukup J; Engelbrecht K; Senderreck M; Clausen T; Radke J Minerva Anestesiol; 2001 Apr; 67(4):325-31. PubMed ID: 11376534 [TBL] [Abstract][Full Text] [Related]
9. Clinical performance of a blood gas monitor: a prospective, multicenter trial. Shapiro BA; Mahutte CK; Cane RD; Gilmour IJ Crit Care Med; 1993 Apr; 21(4):487-94. PubMed ID: 8472565 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of the Paratrend 7 intravascular blood gas monitor during cardiac surgery: comparison with the C4000 in-line blood gas monitor during cardiopulmonary bypass. Venkatesh B; Clutton-Brock TH; Hendry SP J Cardiothorac Vasc Anesth; 1995 Aug; 9(4):412-9. PubMed ID: 7579111 [TBL] [Abstract][Full Text] [Related]
12. Accuracy and utility of a continuous intra-arterial blood gas monitoring system in pediatric patients. Coule LW; Truemper EJ; Steinhart CM; Lutin WA Crit Care Med; 2001 Feb; 29(2):420-6. PubMed ID: 11246326 [TBL] [Abstract][Full Text] [Related]
14. Continuous measurement of blood gases using a combined electrochemical and spectrophotometric sensor. Venkatesh B; Clutton-Brock TH; Hendry SP J Med Eng Technol; 1994; 18(5):165-8. PubMed ID: 7776356 [TBL] [Abstract][Full Text] [Related]
15. Carbon dioxide and oxygen partial pressure measurements in the cerebrospinal fluid in a conventional blood gas analyzer: analysis of bias and precision. Venkatesh B; Boots RJ J Neurol Sci; 1997 Mar; 147(1):5-8. PubMed ID: 9094053 [TBL] [Abstract][Full Text] [Related]
16. Brain parenchyma PO2, PCO2, and pH during and after hypoxic, ischemic brain insult in dogs. McKinley BA; Morris WP; Parmley CL; Butler BD Crit Care Med; 1996 Nov; 24(11):1858-68. PubMed ID: 8917037 [TBL] [Abstract][Full Text] [Related]
17. Preliminary evaluation of a new continuous intra-arterial blood gas monitoring device. Pappert D; Rossaint R; Lewandowski K; Kuhlen R; Gerlach H; Falke KJ Acta Anaesthesiol Scand Suppl; 1995; 107():67-70. PubMed ID: 8599302 [TBL] [Abstract][Full Text] [Related]
18. Performance of a patient-dedicated, on-demand blood gas monitor in medical ICU patients. Mahutte CK; Sasse SA; Chen PA; Holody M Am J Respir Crit Care Med; 1994 Sep; 150(3):865-9. PubMed ID: 8087363 [TBL] [Abstract][Full Text] [Related]
19. Continuous fiberoptic arterial and venous blood gas monitoring in hemorrhagic shock. Oropello JM; Manasia A; Hannon E; Leibowitz A; Benjamin E Chest; 1996 Apr; 109(4):1049-55. PubMed ID: 8635330 [TBL] [Abstract][Full Text] [Related]
20. Continuous intravascular monitoring of pO2 and pCO2. A comparative in vitro-in vivo study. Huchon G; Blayo MC; Vallois JM; Chirico A; Morizet P; Caudebourt C Eur J Intensive Care Med; 1976; 2(1):23-8. PubMed ID: 954761 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]