These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 7818047)

  • 21. Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.
    Rosenbaum A; Kirby C; Breen PH
    Anesthesiology; 2004 Jun; 100(6):1427-37. PubMed ID: 15166562
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Metabolic gas exchange during aortocoronary bypass surgery using a double pump system and mechanical ventilation. A comparison between indirect calorimetry and invasive blood gas measurements using Fick's principle.
    Svensson KL; Henriksson BA; Sonander HG; Stenqvist O
    Acta Anaesthesiol Scand; 1991 Apr; 35(3):185-9. PubMed ID: 2038922
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison between measured and fick-derived values of hemodynamic and oxymetric variables in patients with acute myocardial infarction.
    Pomés Iparraguirre H; Giniger R; Garber VA; Quiroga E; Jorge MA
    Am J Med; 1988 Sep; 85(3):349-52. PubMed ID: 3414730
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A Device for the Quantification of Oxygen Consumption and Caloric Expenditure in the Neonatal Range.
    Nachman E; Clemensen P; Santos K; Cole AR; Polizzotti BD; Hofmann G; Leeman KT; van den Bosch SJ; Kheir JN
    Anesth Analg; 2018 Jul; 127(1):95-104. PubMed ID: 29505450
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Increased intrapulmonary oxygen consumption in mechanically ventilated patients with pneumonia.
    Hensel M; Kox WJ
    Am J Respir Crit Care Med; 1999 Jul; 160(1):137-43. PubMed ID: 10390391
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method.
    Smithies MN; Royston B; Makita K; Konieczko K; Nunn JF
    Crit Care Med; 1991 Nov; 19(11):1401-6. PubMed ID: 1935161
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Oxygen consumption and optimum PEEP in acute respiratory failure.
    Nelson LD; Houtchens BA; Westenskow DR
    Crit Care Med; 1982 Dec; 10(12):857-62. PubMed ID: 6754264
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of oxygen uptake and delivery in critically ill patients: a statistical reappraisal.
    Hanique G; Dugernier T; Laterre PF; Roeseler J; Dougnac A; Reynaert MS
    Intensive Care Med; 1994; 20(1):19-26. PubMed ID: 8163753
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Is the placement of a pulmonary artery catheter still justified solely for the measurement of cardiac output?
    Sakka SG; Reinhart K; Wegscheider K; Meier-Hellmann A
    J Cardiothorac Vasc Anesth; 2000 Apr; 14(2):119-24. PubMed ID: 10794326
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Deriving the arterial Po
    Prisk GK; West JB
    J Appl Physiol (1985); 2019 Oct; 127(4):1067-1074. PubMed ID: 31436512
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The oxygen status of the arterial blood in the critically ill.
    Tulli G; Vignali G; Guadagnucci A; Mondello V
    Scand J Clin Lab Invest Suppl; 1990; 203():107-18. PubMed ID: 2128553
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evidence of O2 supply-dependent VO2 max in the exercise-trained human quadriceps.
    Richardson RS; Grassi B; Gavin TP; Haseler LJ; Tagore K; Roca J; Wagner PD
    J Appl Physiol (1985); 1999 Mar; 86(3):1048-53. PubMed ID: 10066722
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of continuous noninvasive measurement of oxygen consumption in patients with adult respiratory distress syndrome following shock of various etiologies.
    Hankeln KB; Gronemeyer R; Held A; Böhmert F
    Crit Care Med; 1991 May; 19(5):642-9. PubMed ID: 2026026
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Measuring oxygen uptake and carbon dioxide production in critically ill patients using a standard blood gas analyzer.
    Zenger M; Brenner M; Hua P; Haruno M; Wilson AF
    Crit Care Med; 1994 May; 22(5):783-8. PubMed ID: 8181286
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assumed oxygen consumption based on calculation from dye dilution cardiac output: an improved formula.
    Bergstra A; van Dijk RB; Hillege HL; Lie KI; Mook GA
    Eur Heart J; 1995 May; 16(5):698-703. PubMed ID: 7588904
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of metabolic monitors in critically ill, ventilated patients.
    Singer P; Pogrebetsky I; Attal-Singer J; Cohen J
    Nutrition; 2006; 22(11-12):1077-86. PubMed ID: 16973331
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient.
    Brandi LS; Bertolini R; Santini L; Cavani S
    Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Oxygen consumption in the lungs and systemic circulation--different methods of measurement of one data or different data?].
    Perfilova AV; Gromova TA; Lebedinskiĭ KM; Zaĭchik AM
    Anesteziol Reanimatol; 2014; (1):43-7. PubMed ID: 24749309
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Integral assessment of gas exchange during veno-arterial ECMO: accuracy and precision of a modified Fick principle in a porcine model.
    Berger DC; Zwicker L; Nettelbeck K; Casoni D; Heinisch PP; Jenni H; Haenggi M; Gattinoni L; Bachmann KF
    Am J Physiol Lung Cell Mol Physiol; 2023 Feb; 324(2):L102-L113. PubMed ID: 36511508
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device.
    Takala J; Keinänen O; Väisänen P; Kari A
    Crit Care Med; 1989 Oct; 17(10):1041-7. PubMed ID: 2676345
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.