These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
105 related articles for article (PubMed ID: 7818755)
1. Quality assurance and dosimetric evaluation for an endocavitary unit. Klein EE; Purdy JA Med Dosim; 1994; 19(3):151-8. PubMed ID: 7818755 [TBL] [Abstract][Full Text] [Related]
2. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance. Yewondwossen M Med Dosim; 2012; 37(3):250-6. PubMed ID: 22189031 [TBL] [Abstract][Full Text] [Related]
3. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry. Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221 [TBL] [Abstract][Full Text] [Related]
4. Dosimetric evaluation of a widely used kilovoltage x-ray unit for endocavitary radiotherapy. Li XA; Ma CM; Salhani D; Agboola O Med Phys; 1998 Aug; 25(8):1464-71. PubMed ID: 9725135 [TBL] [Abstract][Full Text] [Related]
6. Design and dosimetric characteristics of a high dose rate remotely afterloaded endocavitary applicator system. Meigooni AS; Zhu Y; Williamson JF; Myerson RJ; Teague S; Löffler E; Nussbaum GH; Klein EE; Kodner IJ Int J Radiat Oncol Biol Phys; 1996 Mar; 34(5):1153-63. PubMed ID: 8600101 [TBL] [Abstract][Full Text] [Related]
7. [In-phantom dosimetric measurements as quality control for brachytherapy: System check and constancy check]. Kollefrath M; Bruggmoser G; Nanko N; Gainey M Z Med Phys; 2015 Jun; 25(2):176-85. PubMed ID: 25791738 [TBL] [Abstract][Full Text] [Related]
8. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance. Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606 [TBL] [Abstract][Full Text] [Related]
9. [Development of a quality assurance phantom for brachytherapy: the feasibility of daily check with the phantom]. Kai Y; Murakami R; Maruyama M; Nakaguchi Y; Nagasue N; Kakei K; Takenaga E; Hashida M; Saito T Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Jan; 70(1):34-40. PubMed ID: 24464062 [TBL] [Abstract][Full Text] [Related]
10. Comparison of dosimetric standards of USA and France for HDR brachytherapy. Douysset G; Gouriou J; Delaunay F; DeWerd L; Stump K; Micka J; ; Phys Med Biol; 2005 May; 50(9):1961-78. PubMed ID: 15843730 [TBL] [Abstract][Full Text] [Related]
11. Recommendations on detectors and quality control procedures for brachytherapy beta sources. Kollaard RP; Dries WJ; van Kleffens HJ; Aalbers TH; van der Marel H; Marijnissen HP; Piessens M; Schaart DR; de Vroome H Radiother Oncol; 2006 Feb; 78(2):223-9. PubMed ID: 16457901 [TBL] [Abstract][Full Text] [Related]
12. Calibration and validation of a quality assurance system for 90Sr/90Y radiation source trains. Rosenthal P; Weber W; Förster A; Orth O; Köhler B; Seiler F Phys Med Biol; 2003 Mar; 48(5):573-85. PubMed ID: 12696796 [TBL] [Abstract][Full Text] [Related]
13. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy. Ding A; Xing L; Han B Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618 [TBL] [Abstract][Full Text] [Related]
14. Dosimetry of an endocavitory treatment system. Tobochnik N; Bramlet R; Sischy B Med Phys; 1987; 14(2):265-7. PubMed ID: 3587152 [TBL] [Abstract][Full Text] [Related]
15. Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife(®) Perfexion(TM). Bhatnagar JP; Novotny J; Huq MS Med Phys; 2012 Jan; 39(1):231-6. PubMed ID: 22225292 [TBL] [Abstract][Full Text] [Related]
17. Radiation protection considerations for endocavitary X ray units. Purdy JA; Prasad SC; Walz BJ; Cotter GW Int J Radiat Oncol Biol Phys; 1985 Dec; 11(12):2177-81. PubMed ID: 4066451 [TBL] [Abstract][Full Text] [Related]
18. Dosimetric evaluation of a variable energy superficial X-ray machine with applications for endocavitary radiotherapy techniques. Coffey CW; Morris R; Martin J; Maruyama Y Int J Radiat Oncol Biol Phys; 1989 Mar; 16(3):849-55. PubMed ID: 2921176 [TBL] [Abstract][Full Text] [Related]
19. Quality assurance and independent dosimetry for an intraoperative x-ray device. Eaton DJ Med Phys; 2012 Nov; 39(11):6908-20. PubMed ID: 23127084 [TBL] [Abstract][Full Text] [Related]