BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

403 related articles for article (PubMed ID: 7820736)

  • 1. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of variation of prosthesis size on cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    J Biomed Mater Res; 1994 Sep; 28(9):1055-60. PubMed ID: 7814433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty.
    Cheal EJ; Spector M; Hayes WC
    J Orthop Res; 1992 May; 10(3):405-22. PubMed ID: 1569504
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of stem geometry on mechanics of cemented femoral hip components with a proximal bond.
    Mann KA; Bartel DL; Ayers DC
    J Orthop Res; 1997 Sep; 15(5):700-6. PubMed ID: 9420599
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing.
    O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH
    J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cemented femoral stem performance. Effects of proximal bonding, geometry, and neck length.
    Chang PB; Mann KA; Bartel DL
    Clin Orthop Relat Res; 1998 Oct; (355):57-69. PubMed ID: 9917591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of stem length on mechanics of the femoral hip component after cemented revision.
    Mann KA; Ayers DC; Damron TA
    J Orthop Res; 1997 Jan; 15(1):62-8. PubMed ID: 9066528
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stable partial debonding of the cement interfaces indicated by a finite element model of a total hip prosthesis.
    Lu Z; Ebramzadeh E; McKellop H; Sarmiento A
    J Orthop Res; 1996 Mar; 14(2):238-44. PubMed ID: 8648501
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reinforcement of bone cement around prostheses by pre-coated wire coil: a finite element model study.
    Grosland N; Kim JK; Park JB
    Biomed Mater Eng; 1995; 5(1):29-36. PubMed ID: 7773144
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A finite element study of the initiation of failure of fixation in cemented femoral total hip components.
    Harrigan TP; Kareh JA; O'Connor DO; Burke DW; Harris WH
    J Orthop Res; 1992 Jan; 10(1):134-44. PubMed ID: 1727933
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of stem geometry on stresses within the distal cement mantle in total hip replacement.
    Schmölz W; Gordon DR; Shields AJ; Kirkwood D; Grigoris P
    Technol Health Care; 2000; 8(1):67-73. PubMed ID: 10942992
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty.
    Estok DM; Harris WH
    J Arthroplasty; 2000 Aug; 15(5):584-9. PubMed ID: 10959996
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
    Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
    J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Shape optimization of metal backing for cemented acetabular cup.
    Hedia HS; Abdel-Shafi AA; Fouda N
    Biomed Mater Eng; 2000; 10(2):73-82. PubMed ID: 11086841
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of design parameters on calcar stresses following femoral head arthroplasty.
    Cook SD; Klawitter JJ; Weinstein AM
    J Biomed Mater Res; 1980 Mar; 14(2):133-44. PubMed ID: 7358741
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components.
    Harrigan TP; Harris WH
    J Biomech; 1991; 24(11):1047-58. PubMed ID: 1761581
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bone-cement interface of the glenoid component: stress analysis for varying cement thickness.
    Terrier A; Büchler P; Farron A
    Clin Biomech (Bristol, Avon); 2005 Aug; 20(7):710-7. PubMed ID: 15961203
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.