These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 7820742)

  • 1. Treatment of difficult fractures and nonunions of the humerus and elbow with a modified Küntscher nail.
    Burdeaux BD; York BP
    Iowa Orthop J; 1993; 13():196-203. PubMed ID: 7820742
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Condylar nonunions of the elbow.
    Mitsunaga MM; Bryan RS; Linscheid RL
    J Trauma; 1982 Sep; 22(9):787-91. PubMed ID: 6750144
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Retrograde nailing of humerus shaft fractures with the unreamed humerus nail. An international multicenter study].
    Blum J; Rommens PM; Janzing H; Langendorff HS
    Unfallchirurg; 1998 May; 101(5):342-52. PubMed ID: 9629046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Intramedullary fixation of humerus shaft fractures. An analysis of complications of 2 implants with special reference to outcome after management with the unreamed humerus interlocking nail].
    Vécsei N; Kolonja A; Mousavi M; Vécsei V
    Wien Klin Wochenschr; 2001 Aug; 113(15-16):597-604. PubMed ID: 11571838
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Küntscher intramedullary reaming and nail fixation for nonunion of the humerus.
    Christensen NO
    Clin Orthop Relat Res; 1976 May; (116):222-5. PubMed ID: 1277645
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Treatment of humeral shaft delayed unions and nonunions with humeral locked nails.
    Lin J; Hou SM; Hang YS
    J Trauma; 2000 Apr; 48(4):695-703. PubMed ID: 10780604
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Management of humeral nonunion after the failure of locking intramedullary nails.
    McKee MD; Miranda MA; Riemer BL; Blasier RB; Redmond BJ; Sims SH; Waddell JP; Jupiter JB
    J Orthop Trauma; 1996; 10(7):492-9. PubMed ID: 8892150
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Uninfected nonunion of the humeral diaphyses: review of 21 patients treated with shingling, compression plate, and autologous bone graft.
    Bernard de Dompsure R; Peter R; Hoffmeyer P
    Orthop Traumatol Surg Res; 2010 Apr; 96(2):139-46. PubMed ID: 20417912
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nonunion of the humerus: rigid fixation, bone grafting, and adjunctive bone cement.
    Trotter DH; Dobozi W
    Clin Orthop Relat Res; 1986 Mar; (204):162-8. PubMed ID: 3514032
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study.
    Foster RJ; Dixon GL; Bach AW; Appleyard RW; Green TM
    J Bone Joint Surg Am; 1985 Jul; 67(6):857-64. PubMed ID: 4019533
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Salvage of contaminated fractures of the distal humerus with thin wire external fixation.
    Ring D; Jupiter JB; Toh S
    Clin Orthop Relat Res; 1999 Feb; (359):203-8. PubMed ID: 10078144
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Seidel locked nailing for the treatment of unstable fractures and nonunion of the humerus.
    Corradi M; Petriccioli D; Panno B; Marenghi P
    Chir Organi Mov; 1996; 81(2):189-95. PubMed ID: 8968121
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Unstable nonunions of the distal part of the humerus.
    Ring D; Gulotta L; Jupiter JB
    J Bone Joint Surg Am; 2003 Jun; 85(6):1040-6. PubMed ID: 12783999
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.
    Gessmann J; Königshausen M; Coulibaly MO; Schildhauer TA; Seybold D
    Arch Orthop Trauma Surg; 2016 May; 136(5):631-8. PubMed ID: 26852379
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Complications of locked nailing in humeral shaft fractures.
    Lin J; Shen PW; Hou SM
    J Trauma; 2003 May; 54(5):943-9. PubMed ID: 12777908
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus.
    Spitzer AB; Davidovitch RI; Egol KA
    Injury; 2009 Mar; 40(3):240-4. PubMed ID: 19195653
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Plate and Screw Fixation of Bicolumnar Distal Humerus Fractures: Factors Associated With Loosening or Breakage of Implants or Nonunion.
    Claessen FM; Braun Y; Peters RM; Kolovich GP; Ring D
    J Hand Surg Am; 2015 Oct; 40(10):2045-2051.e2. PubMed ID: 26319772
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Closed intramedullary fixation of humeral shaft fractures.
    Hall RF
    Instr Course Lect; 1987; 36():349-58. PubMed ID: 3437135
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Treatment of un-united fractures of the shaft of the humerus with bent nail.
    Gupta RC; Gaur SC; Tiwari RC; Varma B; Gupta R
    Injury; 1985 Jan; 16(4):276-80. PubMed ID: 3967918
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The use of elastic nails for intramedullary fixation of humeral fractures and nonunions.
    Marchetti PG; Vicenzi G; Impallomeni C; Landi S; Surdo V
    Orthopedics; 2000 Apr; 23(4):343-7. PubMed ID: 10791584
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.