249 related articles for article (PubMed ID: 7825674)
1. Poor correlation between reactive syphilis serology and human immunodeficiency virus testing among potential cornea donors.
Goldberg MA; Laycock KA; Kinard S; Wang H; Pepose JS
Am J Ophthalmol; 1995 Jan; 119(1):1-6. PubMed ID: 7825674
[TBL] [Abstract][Full Text] [Related]
2. Screening potential corneal donors for HIV-1 by polymerase chain reaction and a colorimetric microwell hybridization assay.
Essary LR; Kinard SJ; Butcher A; Wang H; Laycock KA; Donegan E; McCreedy B; Connell S; Batchelor J; Harris J; Spadoro J; Pepose JS
Am J Ophthalmol; 1996 Oct; 122(4):526-34. PubMed ID: 8862050
[TBL] [Abstract][Full Text] [Related]
3. Human immunodeficiency virus p24 antigen testing in cornea donors.
Chung CW; Rapuano CJ; Laibson PR; Lytle RE; Quirk JT; Cohen EJ
Cornea; 2001 Apr; 20(3):277-80. PubMed ID: 11322416
[TBL] [Abstract][Full Text] [Related]
4. Comparison of seropositivity of human immunodeficiency virus, hepatitis B virus, hepatitis C virus, and syphilis among Hospital Cornea Retrieval Programme-Donors versus voluntary cornea donors at a large eye bank in Eastern India.
Basak S; Basak SK; Biswas B
Indian J Ophthalmol; 2017 Nov; 65(11):1138-1142. PubMed ID: 29133639
[TBL] [Abstract][Full Text] [Related]
5. Predictive value of past and current screening tests for syphilis in blood donors: changing from a rapid plasma reagin test to an automated specific treponemal test for screening.
Aberle-Grasse J; Orton SL; Notari E; Layug LP; Cable RG; Badon S; Popovsky MA; Grindon AJ; Lenes BA; Williams AE
Transfusion; 1999 Feb; 39(2):206-11. PubMed ID: 10037133
[TBL] [Abstract][Full Text] [Related]
6. Improving syphilis screening in deceased organ donors.
Theodoropoulos N; Jaramillo A; Penugonda S; Wasik C; Brooks K; Ladner DP; Jendrisak MD; Ison MG
Transplantation; 2015 Feb; 99(2):438-43. PubMed ID: 25073035
[TBL] [Abstract][Full Text] [Related]
7. Detection and analysis of blood donors seropositive for syphilis.
Attie A; de Almeida-Neto C; S Witkin S; Derriga J; Nishiya AS; Ferreira JE; Costa NSX; Alves Salles N; Facincani T; Levi JE; Sabino EC; Rocha V; Mendrone-Jr A; Ferreira SC
Transfus Med; 2021 Apr; 31(2):121-128. PubMed ID: 33480044
[TBL] [Abstract][Full Text] [Related]
8. Biological false-positive syphilis test results for women infected with human immunodeficiency virus.
Augenbraun MH; DeHovitz JA; Feldman J; Clarke L; Landesman S; Minkoff HM
Clin Infect Dis; 1994 Dec; 19(6):1040-4. PubMed ID: 7888531
[TBL] [Abstract][Full Text] [Related]
9. Performance of a Dual Human Immunodeficiency Virus/Syphilis Rapid Test Compared With Conventional Serological Testing for Syphilis and Human Immunodeficiency Virus in a Laboratory Setting: Results From the Zimbabwe STI Etiology Study.
Rietmeijer CA; Mungati M; Kilmarx PH; Barr BT; Gonese E; Kularatne RS; Lewis DA; Klausner JD; Rodgers L; Handsfield HH
Sex Transm Dis; 2019 Sep; 46(9):584-587. PubMed ID: 31181033
[TBL] [Abstract][Full Text] [Related]
10. New developments in serologic screening of corneal donors for HIV-1 and hepatitis B virus infections.
Pepose JS; Buerger DG; Paul DA; Quinn TC; Darragh TM; Donegan E
Ophthalmology; 1992 Jun; 99(6):879-88. PubMed ID: 1630777
[TBL] [Abstract][Full Text] [Related]
11. Is serological testing a reliable tool in laboratory diagnosis of syphilis? Meta-analysis of eight external quality control surveys performed by the german infection serology proficiency testing program.
Müller I; Brade V; Hagedorn HJ; Straube E; Schörner C; Frosch M; Hlobil H; Stanek G; Hunfeld KP
J Clin Microbiol; 2006 Apr; 44(4):1335-41. PubMed ID: 16597859
[TBL] [Abstract][Full Text] [Related]
12. Confirmatory serological testing of blood donors positive on TPHA screening in Singapore.
Wong SS; Teo DL; Chan RK
Int J STD AIDS; 1997 Dec; 8(12):760-3. PubMed ID: 9433950
[TBL] [Abstract][Full Text] [Related]
13. Absence of risk factors for false-positive test results in blood donors with a reactive test result in an automated treponemal test (PK-TP) for syphilis.
Orton SL; Dodd RY; Williams AE;
Transfusion; 2001 Jun; 41(6):744-50. PubMed ID: 11399813
[TBL] [Abstract][Full Text] [Related]
14. Laboratory diagnosis and interpretation of tests for syphilis.
Larsen SA; Steiner BM; Rudolph AH
Clin Microbiol Rev; 1995 Jan; 8(1):1-21. PubMed ID: 7704889
[TBL] [Abstract][Full Text] [Related]
15. Nucleic acid testing and tissue safety: an eye bank's five-year review of HIV and hepatitis testing for donor corneas.
Heck E; Brown A; Cavanagh HD
Cornea; 2013 Apr; 32(4):503-5. PubMed ID: 23023406
[TBL] [Abstract][Full Text] [Related]
16. Specific syphilis serological tests may become negative in HIV infection.
Johnson PD; Graves SR; Stewart L; Warren R; Dwyer B; Lucas CR
AIDS; 1991 Apr; 5(4):419-23. PubMed ID: 2059384
[TBL] [Abstract][Full Text] [Related]
17. Discordant results from reverse sequence syphilis screening--five laboratories, United States, 2006-2010.
Centers for Disease Control and Prevention (CDC)
MMWR Morb Mortal Wkly Rep; 2011 Feb; 60(5):133-7. PubMed ID: 21307823
[TBL] [Abstract][Full Text] [Related]
18. Syphilis serology in human immunodeficiency virus infection: evidence for false-negative fluorescent treponemal testing.
Erbelding EJ; Vlahov D; Nelson KE; Rompalo AM; Cohn S; Sanchez P; Quinn TC; Brathwaite W; Thomas DL
J Infect Dis; 1997 Nov; 176(5):1397-400. PubMed ID: 9359747
[TBL] [Abstract][Full Text] [Related]
19. The impact of combined antiretroviral therapy on biologic false-positive rapid plasma reagin serologies in a longitudinal cohort of HIV-infected persons.
Oboho IK; Gebo KA; Moore RD; Ghanem KG
Clin Infect Dis; 2013 Oct; 57(8):1197-202. PubMed ID: 23828913
[TBL] [Abstract][Full Text] [Related]
20. Association of biologic false-positive reactions for syphilis with human immunodeficiency virus infection.
Rompalo AM; Cannon RO; Quinn TC; Hook EW
J Infect Dis; 1992 Jun; 165(6):1124-6. PubMed ID: 1583332
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]