These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 7826805)

  • 1. A universal nitric oxide delivery system.
    Young JD
    Br J Anaesth; 1994 Nov; 73(5):700-2. PubMed ID: 7826805
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laboratory evaluation of the I-NOvent nitric oxide delivery device.
    Young JD; Roberts M; Gale LB
    Br J Anaesth; 1997 Sep; 79(3):398-401. PubMed ID: 9389867
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An appraisal of techniques for administration of gaseous nitric oxide.
    Tibballs J; Hochmann M; Carter B; Osborne A
    Anaesth Intensive Care; 1993 Dec; 21(6):844-7. PubMed ID: 8122745
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow-proportional administration of nitric oxide with a new delivery system: inspiratory nitric oxide concentration fluctuation during different flow conditions.
    Sydow M; Bristow F; Zinserling J; Allen SJ
    Chest; 1997 Aug; 112(2):496-504. PubMed ID: 9266890
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variation of nitric oxide concentration during inspiration.
    Sydow M; Bristow F; Zinserling J; Allen SJ
    Crit Care Med; 1997 Feb; 25(2):365-71. PubMed ID: 9034278
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation.
    Imanaka H; Hess D; Kirmse M; Bigatello LM; Kacmarek RM; Steudel W; Hurford WE
    Anesthesiology; 1997 Mar; 86(3):676-88. PubMed ID: 9066335
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A low flow open circle system for anaesthesia. Part I: Laboratory evaluation at normal and high frequencies.
    Chakrabarti MK; Stacey RG; Holdcroft A; Whitwam JG
    Anaesthesia; 1990 Apr; 45(4):314-7. PubMed ID: 2337217
    [TBL] [Abstract][Full Text] [Related]  

  • 9. "Ventilator bellow standstill".
    Wong DT; Li AQ
    Can J Anaesth; 2005; 52(7):774-5. PubMed ID: 16103397
    [No Abstract]   [Full Text] [Related]  

  • 10. Variation of inhaled nitric oxide concentration with the use of a continuous flow ventilator.
    De Jaegere AP; Jacobs FI; Laheij NG; van den Anker JN
    Crit Care Med; 1997 Jun; 25(6):995-1002. PubMed ID: 9201053
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Delivery of inhaled nitric oxide using the Ohmeda INOvent Delivery System.
    Kirmse M; Hess D; Fujino Y; Kacmarek RM; Hurford WE
    Chest; 1998 Jun; 113(6):1650-7. PubMed ID: 9631807
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A low flow open circle system for anaesthesia. Part 2: Clinical evaluation.
    Holdcroft A; Chakrabarti MK; Whitwam JG
    Anaesthesia; 1990 Apr; 45(4):318-21. PubMed ID: 2186649
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A portable nitric oxide scavenging system designed for use on neonatal transport.
    Dhillon JS; Kronick JB; Singh NC; Johnson CC
    Crit Care Med; 1996 Jun; 24(6):1068-71. PubMed ID: 8681575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The oxygen and volatile anaesthetic delivery characteristics during spontaneous ventilation using a non-rebreathing coaxial anaesthesia system.
    Day SK
    Kathmandu Univ Med J (KUMJ); 2005; 3(1):22-5. PubMed ID: 16401939
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of Nitric Oxide Delivery Device on Tidal Volume Accuracy During Mechanical Ventilation at Small Tidal Volumes.
    Ranallo CD; Thurman TL; Holt SJ; Frank-Pearce SG; Anderson MP; Heulitt MJ
    Respir Care; 2020 Nov; 65(11):1641-1647. PubMed ID: 32518087
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nitric oxide delivery system.
    Supkis DE
    Anesth Analg; 2000 Oct; 91(4):1041-2. PubMed ID: 11004079
    [No Abstract]   [Full Text] [Related]  

  • 17. Nitric oxide administration after the ventilator: evaluation of mixing conditions.
    Westfelt UN; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 1997 Feb; 41(2):266-73. PubMed ID: 9062612
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Behavior of nitric oxide infused at constant flow rates directly into a breathing circuit during controlled mechanical ventilation.
    Skimming JW; Blanch PB; Banner MJ
    Crit Care Med; 1997 Aug; 25(8):1410-6. PubMed ID: 9267958
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Development of a nitric oxide inhaling equipment cooperated with the ventilator synchronously].
    Zhang HT; Liu ZM; Zhu XF
    Zhongguo Yi Liao Qi Xie Za Zhi; 2006 May; 30(3):188-91. PubMed ID: 16929776
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A delivery system for inhalation of nitric oxide evaluated with chemiluminescence, electrochemical fuel cells, and capnography.
    Lindberg L; Rydgren G; Larsson A; Olsson SG; Nordström L
    Crit Care Med; 1997 Jan; 25(1):190-6. PubMed ID: 8989197
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.