219 related articles for article (PubMed ID: 7830996)
1. Prospective comparison of the Heine retinometer with the Mentor Guyton-Minkowski potential acuity meter for the assessment of potential visual acuity before cataract surgery.
Tharp A; Cantor L; Yung CW; Shoemaker J
Ophthalmic Surg; 1994; 25(9):576-9. PubMed ID: 7830996
[TBL] [Abstract][Full Text] [Related]
2. Mentor Guyton-Minkowski potential acuity meter.
Waltuck MH
Ophthalmic Surg; 1994; 25(9):657. PubMed ID: 7831018
[No Abstract] [Full Text] [Related]
3. Potential acuity pinhole: a simple method to measure potential visual acuity in patients with cataracts, comparison to potential acuity meter.
Melki SA; Safar A; Martin J; Ivanova A; Adi M
Ophthalmology; 1999 Jul; 106(7):1262-7. PubMed ID: 10406603
[TBL] [Abstract][Full Text] [Related]
4. Measurement of potential visual acuity in 343 patients with cataracts. A prospective clinical study.
Tetz MR; Klein U; Völcker HE
Ger J Ophthalmol; 1992; 1(6):403-8. PubMed ID: 1490139
[TBL] [Abstract][Full Text] [Related]
5. Comparison of the potential acuity meter and pinhole tests in predicting postoperative visual acuity after cataract surgery.
Uy HS; Munoz VM
J Cataract Refract Surg; 2005 Mar; 31(3):548-52. PubMed ID: 15811743
[TBL] [Abstract][Full Text] [Related]
6. Illuminated near card assessment of potential acuity in eyes with cataract.
Hofeldt AJ; Weiss MJ
Ophthalmology; 1998 Aug; 105(8):1531-6. PubMed ID: 9709769
[TBL] [Abstract][Full Text] [Related]
7. Comparison of the potential acuity meter and the visometer in cataract patients.
Reid O; Maberley DA; Hollands H
Eye (Lond); 2007 Feb; 21(2):195-9. PubMed ID: 16273082
[TBL] [Abstract][Full Text] [Related]
8. [Clinical study for prediction of postoperative visual acuity in cataract patients].
Tashiro T; Masuda H; Ichioka T
Meikai Daigaku Shigaku Zasshi; 1990; 19(1):117-21. PubMed ID: 2134282
[TBL] [Abstract][Full Text] [Related]
9. A clinical evaluation of the potential acuity meter in 210 cases.
Severin TD; Severin SL
Ann Ophthalmol; 1988 Oct; 20(10):373-5. PubMed ID: 3207307
[TBL] [Abstract][Full Text] [Related]
10. [Reliability of predictable postoperative visual acuity of cataracts as measured by Heine Lambda 100 retinometer preoperatively].
Colombo-Barboza GN; Hida WT; Van den Berg A; Rocha HC; Malavazzi GR; Barboza LR; Colombo-Barboza MM; Colombo-Barboza MN
Arq Bras Oftalmol; 2010; 73(3):244-9. PubMed ID: 20730281
[TBL] [Abstract][Full Text] [Related]
11. A comparison of the potential acuity meter (PAM) and the illuminated near card (INC) in patients undergoing phacoemulsification.
Chang MA; Airiani S; Miele D; Braunstein RE
Eye (Lond); 2006 Dec; 20(12):1345-51. PubMed ID: 16179931
[TBL] [Abstract][Full Text] [Related]
12. Potential acuity meter versus scanning laser ophthalmoscope to predict visual acuity in cataract patients.
Cuzzani OE; Ellant JP; Young PW; Gimbel HV; Rydz M
J Cataract Refract Surg; 1998 Feb; 24(2):263-9. PubMed ID: 9530603
[TBL] [Abstract][Full Text] [Related]
13. Clinician versus potential acuity test predictions of visual outcome after cataract surgery.
Vianya-Estopa M; Douthwaite WA; Funnell CL; Elliott DB
Optometry; 2009 Aug; 80(8):447-53. PubMed ID: 19635437
[TBL] [Abstract][Full Text] [Related]
14. [Clinical study for postoperative visual acuity in cataract patients with the potential acuity meter].
Tang X; Xing XJ; Fang ZL
Zhonghua Yan Ke Za Zhi; 2008 Feb; 44(2):131-4. PubMed ID: 18683697
[TBL] [Abstract][Full Text] [Related]
15. Five-year change in visual acuity following cataract surgery in an older community: the Blue Mountains Eye Study.
Panchapakesan J; Rochtchina E; Mitchell P
Eye (Lond); 2004 Mar; 18(3):278-82. PubMed ID: 15004577
[TBL] [Abstract][Full Text] [Related]
16. Predicting cataract surgery results using a macular function test.
Vryghem JC; Van Cleynenbreugel H; Van Calster J; Leroux K
J Cataract Refract Surg; 2004 Nov; 30(11):2349-53. PubMed ID: 15519087
[TBL] [Abstract][Full Text] [Related]
17. [Comparison of preoperative retinometer values with postoperative visual acuity after surgery of epiretinal membranes].
Leisser C; Bartl G
Klin Monbl Augenheilkd; 2004 Jun; 221(6):485-8. PubMed ID: 15236109
[TBL] [Abstract][Full Text] [Related]
18. Potential acuity meter for predicting visual acuity after Nd:YAG posterior capsulotomy.
Lue CL; Chen SC; Tsai WF
J Clin Laser Med Surg; 1991 Feb; 9(1):59-61. PubMed ID: 10149445
[TBL] [Abstract][Full Text] [Related]
19. Potential vision tests in patients with cataracts.
Lasa MS; Datiles MB; Freidlin V
Ophthalmology; 1995 Jul; 102(7):1007-11. PubMed ID: 9121743
[TBL] [Abstract][Full Text] [Related]
20. Capabilities of potential vision test measurements: clinical evaluation in the presence of cataract or macular disease.
Vianya-EstopĂ M; Douthwaite WA; Noble BA; Elliott DB
J Cataract Refract Surg; 2006 Jul; 32(7):1151-60. PubMed ID: 16857502
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]