173 related articles for article (PubMed ID: 7839778)
21. Finer gauge of cutting but not pencil-point needles correlate with lower incidence of post-dural puncture headache: a meta-regression analysis.
Zorrilla-Vaca A; Healy R; Zorrilla-Vaca C
J Anesth; 2016 Oct; 30(5):855-63. PubMed ID: 27468735
[TBL] [Abstract][Full Text] [Related]
22. Difficulties in spinal needle use. Insertion characteristics and failure rates associated with 25-, 27- and 29-gauge Quincke-type spinal needles.
Tarkkila P; Huhtala J; Salminen U
Anaesthesia; 1994 Aug; 49(8):723-5. PubMed ID: 7943709
[TBL] [Abstract][Full Text] [Related]
23. Postdural puncture headache: comparison of 25-gauge Whitacre and Quincke needles.
Buettner J; Wresch KP; Klose R
Reg Anesth; 1993; 18(3):166-9. PubMed ID: 8323889
[TBL] [Abstract][Full Text] [Related]
24. [Development of incidence of post-dural puncture headache in patients undergoing caesarean section in spinal anaesthesia at the Department of Obstetrics and Gynecology in Olomouc during 2003-2004].
L'ubuský M; Berta E; Procházka M; Marek O; Kudela M
Cas Lek Cesk; 2006; 145(3):204-8. PubMed ID: 16634479
[TBL] [Abstract][Full Text] [Related]
25. Whitacre or Quincke needles--does it really matter.
Eriksson AL; Hallén B; Lagerkranser M; Persson E; Sköldefors E
Acta Anaesthesiol Scand Suppl; 1998; 113():17-20. PubMed ID: 9932114
[TBL] [Abstract][Full Text] [Related]
26. Post dural puncture headache in obstetric patients: experience from a West African teaching hospital.
Nafiu OO; Salam RA; Elegbe EO
Int J Obstet Anesth; 2007 Jan; 16(1):4-7. PubMed ID: 17126005
[TBL] [Abstract][Full Text] [Related]
27. Puncture technique and postural postdural puncture headache. A randomised, double-blind study comparing transverse and parallel puncture.
Flaatten H; Thorsen T; Askeland B; Finne M; Rosland J; Hansen T; Rønhovde K; Wisborg T
Acta Anaesthesiol Scand; 1998 Nov; 42(10):1209-14. PubMed ID: 9834807
[TBL] [Abstract][Full Text] [Related]
28. Post-dural puncture headache in young patients. A comparative study between the use of 0.52 mm (25-gauge) and 0.33 mm (29-gauge) spinal needles.
Geurts JW; Haanschoten MC; van Wijk RM; Kraak H; Besse TC
Acta Anaesthesiol Scand; 1990 Jul; 34(5):350-3. PubMed ID: 2143882
[TBL] [Abstract][Full Text] [Related]
29. Postdural puncture headache. A comparison between 26- and 29-gauge needles in young patients.
Flaatten H; Rodt SA; Vamnes J; Rosland J; Wisborg T; Koller ME
Anaesthesia; 1989 Feb; 44(2):147-9. PubMed ID: 2929939
[TBL] [Abstract][Full Text] [Related]
30. Classification and severity of postdural puncture headache. Comparison of 26-gauge and 27-gauge Quincke needle for spinal anaesthesia in day-care surgery in patients under 45 years.
Corbey MP; Berg P; Quaynor H
Anaesthesia; 1993 Sep; 48(9):776-81. PubMed ID: 8214496
[TBL] [Abstract][Full Text] [Related]
31. Post-dural puncture headache in young adults: comparison of two small-gauge spinal catheters with different needle design.
Gosch UW; Hueppe M; Hallschmid M; Born J; Schmucker P; Meier T
Br J Anaesth; 2005 May; 94(5):657-61. PubMed ID: 15722381
[TBL] [Abstract][Full Text] [Related]
32. The use of Quincke and Whitacre 27-gauge needles in orthopedic patients: incidence of failed spinal anesthesia and postdural puncture headache.
Lynch J; Kasper SM; Strick K; Topalidis K; Schaaf H; Zech D; Krings-Ernst I
Anesth Analg; 1994 Jul; 79(1):124-8. PubMed ID: 8010421
[TBL] [Abstract][Full Text] [Related]
33. Post-dural puncture headache: a comparison of the Sprotte and Yale needles in urological surgery.
Harrison DA; Langham BT
Eur J Anaesthesiol; 1994 Jul; 11(4):325-7. PubMed ID: 7925339
[TBL] [Abstract][Full Text] [Related]
34. High incidence of post-dural puncture headache in patients with spinal saddle block induced with Quincke needles for anorectal surgery: a randomised clinical trial.
Schmittner MD; Terboven T; Dluzak M; Janke A; Limmer ME; Weiss C; Bussen DG; Burmeister MA; Beck GC
Int J Colorectal Dis; 2010 Jun; 25(6):775-81. PubMed ID: 20148254
[TBL] [Abstract][Full Text] [Related]
35. Comparison of 25-gauge, Quincke and Whitacre needles for postdural puncture headache in obstetric patients.
Bano F; Haider S; Aftab S; Sultan ST
J Coll Physicians Surg Pak; 2004 Nov; 14(11):647-50. PubMed ID: 15530271
[TBL] [Abstract][Full Text] [Related]
36. Needle design does not affect the success rate of spinal anaesthesia or the incidence of postpuncture complications in children.
Kokki H; Heikkinen M; Turunen M; Vanamo K; Hendolin H
Acta Anaesthesiol Scand; 2000 Feb; 44(2):210-3. PubMed ID: 10695916
[TBL] [Abstract][Full Text] [Related]
37. Post dural puncture headache following combined spinal epidural or epidural anaesthesia in obstetric patients.
van de Velde M; Teunkens A; Hanssens M; van Assche FA; Vandermeersch E
Anaesth Intensive Care; 2001 Dec; 29(6):595-9. PubMed ID: 11771601
[TBL] [Abstract][Full Text] [Related]
38. Atraucan: a new needle for spinal anesthesia.
Scott DB; Dittmann M; Clough DG; Van Steenberge A; Morrison LM; Van Zundert A; Joos SS; Eisenach JC
Reg Anesth; 1993; 18(4):213-7. PubMed ID: 8398953
[TBL] [Abstract][Full Text] [Related]
39. Headache after spinal anesthesia for cesarean section: a comparison of the 27-gauge Quincke and 24-gauge Sprotte needles.
Mayer DC; Quance D; Weeks SK
Anesth Analg; 1992 Sep; 75(3):377-80. PubMed ID: 1510258
[TBL] [Abstract][Full Text] [Related]
40. Postdural puncture headache after continuous spinal anesthesia with 18-gauge and 20-gauge needles.
Mazze RI; Fujinaga M
Reg Anesth; 1993; 18(1):47-51. PubMed ID: 8448099
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]