These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 7845796)

  • 1. Clinical study of a new activity sensor for rate adaptive pacing controlled by electrical signals generated by the kinetic energy of a moving magnetic ball.
    Faerastrand S; Ohm OJ
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1944-9. PubMed ID: 7845796
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-year experience with rate-modulated pacing controlled by mixed venous oxygen saturation.
    Windecker S; Bubien RS; Halperin L; Moore A; Kay GN
    Pacing Clin Electrophysiol; 1998 Jul; 21(7):1396-404. PubMed ID: 9670183
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adequacy of pacing rate during exercise in rate responsive ventricular pacing.
    Hasegawa A; Hatori M; Amano M; Iijima T; Adachi H; Yamaguchi E; Fukuda T; Murata K; Nagai R
    Pacing Clin Electrophysiol; 1997 Feb; 20(2 Pt 1):307-12. PubMed ID: 9058868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Importance of AV synchronous pacing during low intensity exercise evaluated by oxygen kinetics.
    Rickli H; Brunner-La Rocca HP; Maccarter DJ; Duru F; Candinas R
    Pacing Clin Electrophysiol; 2000 Feb; 23(2):174-9. PubMed ID: 10709225
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual sensor VVIR mode pacing: is it worth it?
    Sulke N; Tan K; Kamalvand K; Bostock J; Bucknall C
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1560-7. PubMed ID: 8946451
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: quantification of chronotropic behavior during daily activities and maximal exercise.
    Lau CP; Tai YT; Leung WH; Leung SK; Li JP; Wong CK; Lee IS; Yerich C; Erickson M
    Pacing Clin Electrophysiol; 1994 Dec; 17(12 Pt 1):2236-46. PubMed ID: 7885930
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Usefulness of transcutaneous triggering of conventional implanted pulse generators by an activity-sensing pacemaker for predicting effectiveness of rate response pacing.
    Fetter J; Benditt DG; Mianulli M
    Am J Cardiol; 1988 Nov; 62(13):901-5. PubMed ID: 3177238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rate-modulated cardiac pacing based on transthoracic impedance measurements of minute ventilation: correlation with exercise gas exchange.
    Kay GN; Bubien RS; Epstein AE; Plumb VJ
    J Am Coll Cardiol; 1989 Nov; 14(5):1283-9. PubMed ID: 2808984
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-chamber cardiac pacing with activity-initiated chronotropic response: evaluation by cardiopulmonary exercise testing.
    Benditt DG; Mianulli M; Fetter J; Benson DW; Dunnigan A; Molina E; Gornick CC; Almquist A
    Circulation; 1987 Jan; 75(1):184-91. PubMed ID: 3791604
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exercise hemodynamic benefits of rate adaptive ventricular pacing.
    Ma J; Wang F; Zhang K; Yu P; Wang J; Chen X
    Chin Med J (Engl); 1996 Jun; 109(6):459-62. PubMed ID: 9206079
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of maximum heart rate on oxygen kinetics and exercise performance at low and high workloads.
    Carmouche DG; Bubien RS; Kay GN
    Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):679-86. PubMed ID: 9584297
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers.
    Lau CP; Wong CK; Leung WH; Liu WX
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1832-7. PubMed ID: 1704550
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing.
    Nowak B; Voigtländer T; Himmrich E; Liebrich A; Poschmann G; Epperlein S; Treese N; Meyer J
    Am J Cardiol; 1995 May; 75(14):904-7. PubMed ID: 7732998
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rate modulated pacing based on right ventricular dP/dt: quantitative analysis of chronotropic response.
    Kay GN; Philippon F; Bubien RS; Plumb VJ
    Pacing Clin Electrophysiol; 1994 Aug; 17(8):1344-54. PubMed ID: 7971396
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A randomized double-blind crossover comparison of four rate-responsive pacing modes.
    Sulke N; Chambers J; Dritsas A; Sowton E
    J Am Coll Cardiol; 1991 Mar; 17(3):696-706. PubMed ID: 1993790
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Importance of heart rate response during exercise in patients using atrioventricular synchronous and ventricular pacemakers.
    McMeekin JD; Lautner D; Hanson S; Gulamhusein SS
    Pacing Clin Electrophysiol; 1990 Jan; 13(1):59-68. PubMed ID: 1689036
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rate adaptive pacing in sick sinus syndrome: effects of pacing modes and intrinsic conduction on physiological responses, arrhythmias, symptomatology and quality of life.
    Lau CP; Tai YT; Leung WH; Wong CK; Lee P; Chung FL
    Eur Heart J; 1994 Nov; 15(11):1445-55. PubMed ID: 7835358
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block.
    Hargreaves MR; Channon KM; Cripps TR; Gardner M; Ormerod OJ
    Br Heart J; 1995 Oct; 74(4):397-402. PubMed ID: 7488454
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Use of a rate responsive pacemaker in sick sinus syndrome].
    Ito T; Nishino M; Nakagawa T; Okada T; Hasegawa S; Kuryu T; Ebisuno S; Ohnishi S; Tanahashi H; Yasuno M
    Kokyu To Junkan; 1993 Jan; 41(1):63-7. PubMed ID: 8434162
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of the pacing rate on the atrioventricular conduction time during aerobic and anaerobic exercise: basic concepts for a dromotropically controlled rate responsive pacemaker.
    Meine M; Hexamer M; Werner J; Israel CW; Mügge A; Lemke B; Barmeyer J
    Pacing Clin Electrophysiol; 1999 Dec; 22(12):1782-91. PubMed ID: 10642132
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.