BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

277 related articles for article (PubMed ID: 7856932)

  • 1. [Enzymatic determination of sodium, potassium and chloride in plasma].
    Chalas J; Francoual J; Lindenbaum A
    Ann Biol Clin (Paris); 1994; 52(5):333-9. PubMed ID: 7856932
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Evaluation of enzymatic methods for the determination of plasma sodium and potassium using the Hitachi 747 analytic system].
    Pei P; Cigler C; Vonderschmitt DJ
    Schweiz Med Wochenschr; 1991 Dec; 121(50):1883-6. PubMed ID: 1759149
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Results of multicenter evaluation of reagents for determination of sodium, potassium and chloride ions using enzyme activation].
    Ehrhardt V; Baadenhuijsen H; Brenna S; Browne M; Garcia-Beltrán L; Hellsing K; Külpmann WR; Paschen K; Pascual-Mostaza C; Pei P
    Wien Klin Wochenschr Suppl; 1992; 192():12-21. PubMed ID: 1502819
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analyses with the KODAK-Ektachem. Accuracy control using reference method values and the influence of protein concentration. Part I. Electrolytes.
    Külpmann WR; Maibaum P; Sonntag O
    J Clin Chem Clin Biochem; 1990 Nov; 28(11):825-33. PubMed ID: 2077095
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of serum sodium and chloride results for Flame IV-Auto Analyzer II, SMAC, Ektachem 400, and Nova 4 clinical analyzer systems.
    Jacklyn CL; Ryder DI; Matte SJ; Moss MA; Dymond LC; Cousins CL; MacAulay MA
    Clin Biochem; 1988 Jun; 21(3):167-72. PubMed ID: 3390906
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The reliability of the simultaneous determination of sodium, potassium and chloride in serum with the automatic analyser C 4 (Perkin Elmer)].
    Haeckel R
    Z Klin Chem Klin Biochem; 1972 Feb; 10(2):86-90. PubMed ID: 4652490
    [No Abstract]   [Full Text] [Related]  

  • 7. Influence of protein on the determination of sodium, potassium and chloride in serum by Ektachem DT 60 with the DTE module; evaluation with special attention to a possible protein error by flame atomic emission spectrometry and ion-selective electrodes; proposals to their calibration.
    Külpmann WR
    J Clin Chem Clin Biochem; 1989 Oct; 27(10):815-24. PubMed ID: 2600555
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparison of ion-selective electrodes and flame photometry for the determination of serum Na+ and K+ for clinical purposes (author's transl)].
    Preusse CJ; Fuchs C
    J Clin Chem Clin Biochem; 1979 Oct; 17(10):639-45. PubMed ID: 501292
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of serum electrolyte results by Technicon's Flame III and Flame IV AutoAnalyser system.
    Jacklyn CL; Kriz CD; MacAulay MA
    Clin Biochem; 1978 Feb; 11(1):10-5. PubMed ID: 630697
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multicentre evaluation of the Boehringer Mannheim/Hitachi 717 analysis system.
    Baadenhuijsen H; Bayer PM; Keller H; Knedel M; Montalbetti N; Brenna S; Prencipe L; Vassault A; Bailly M; Phung HT
    J Clin Chem Clin Biochem; 1990 Apr; 28(4):261-9. PubMed ID: 2193104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The dry chemical system Kodak Ectachem DT 60. Working methods, performance and suitability for laboratory diagnosis in dogs and cats].
    Scholz U; Hirschberger J
    Tierarztl Prax; 1989; 17(3):327-37. PubMed ID: 2815071
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Patient-adapted, ion selective analysis--characteristics of a new instrument].
    Dennhardt R; Frucht U; Leuchtmann D
    Anasth Intensivther Notfallmed; 1987 Dec; 22(6):294-7. PubMed ID: 3439593
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Routine clinical chemical analysis with prepared reagent carriers].
    Wisser H; Knoll E; Ratge D
    J Clin Chem Clin Biochem; 1986 Feb; 24(2):147-54. PubMed ID: 3711798
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Application of ion-selective electrodes for determining ion concentration in blood of irradiated rabbits].
    Makhlina AM; Beliustin AA; Grekovich AL; Razumova NA; Abuzina GN
    Ukr Biokhim Zh; 1977; 49(4):112-7. PubMed ID: 898310
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multilayer film analysis: evaluation of ion-selective electrolyte slides.
    Costello P; Kubasik NP; Brody BB; Sine HE; Bertsch JA; D'Souza JP
    Clin Chem; 1983 Jan; 29(1):129-32. PubMed ID: 6401231
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analytical performance of the random access analyser Hitachi 737. A multicentre evaluation.
    Knedel M; Haeckel R; Seidel D; Thiery J; Vonderschmitt DJ; Haenseler E
    J Clin Chem Clin Biochem; 1986 Jun; 24(6):409-32. PubMed ID: 3746206
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Different effect of Intralipid and triacylglycerol rich lipoproteins on the Kodak Ektachem serum cholesterol determination.
    Cobbaert C; Tricarico A
    Eur J Clin Chem Clin Biochem; 1993 Feb; 31(2):107-9. PubMed ID: 8467010
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Circadian changes in blood ionized calcium, sodium, potassium, and chloride concentrations and pH in cattle.
    Bajcsy CA; Reiczigel J; Szenci O
    Am J Vet Res; 1999 Aug; 60(8):945-8. PubMed ID: 10451202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical evaluation of the Technico Stat/Ion system.
    Slaunwhite D; Clements JC; Reynoso G
    Clin Biochem; 1977 Feb; 10(1):44-6. PubMed ID: 837527
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a direct potentiometric method for sodium and potassium used in the Du Pont aca.
    Koch DD; Parrish D; Ladenson JH
    Clin Chem; 1983 Jun; 29(6):1090-2. PubMed ID: 6851101
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.