BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 7864731)

  • 1. Late pathophysiologic sequelae after utilization of an intravenacaval oxygenator in experimental animals.
    Henrie J; Imai H; Bagley B; Bezzant T; Mortensen JD
    Artif Organs; 1994 Nov; 18(11):822-5. PubMed ID: 7864731
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo gas transfer performance of the intravascular oxygenator in acute respiratory failure.
    Conrad SA; Zwischenberger JB; Eggerstedt JM; Bidani A
    Artif Organs; 1994 Nov; 18(11):840-5. PubMed ID: 7864734
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.
    Imai H; Schaap RN; Mortensen JD
    Artif Organs; 1994 Nov; 18(11):818-21. PubMed ID: 7864730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Major findings from the clinical trials of the intravascular oxygenator.
    Conrad SA; Bagley A; Bagley B; Schaap RN
    Artif Organs; 1994 Nov; 18(11):846-63. PubMed ID: 7864735
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intravenacaval membrane oxygenation and carbon dioxide removal in severe acute respiratory failure.
    Conrad SA; Eggerstedt JM; Grier LR; Morris VF; Romero MD
    Chest; 1995 Jun; 107(6):1689-97. PubMed ID: 7781369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of an intravascular oxygenator/carbon dioxide removal device in an ovine smoke inhalation injury model.
    Cox CS; Zwischenberger JB; Traber LD; Traber DL; Herndon DN
    ASAIO Trans; 1991; 37(3):M411-3. PubMed ID: 1751213
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Significant enhancement of carbon dioxide removal by a new prototype IVOX.
    Nguyen TT; Zwischenberger JB; Tao W; Traber DL; Herndon DN; Duncan CC; Bush P; Bidani A
    ASAIO J; 1993; 39(3):M719-24. PubMed ID: 8268632
    [TBL] [Abstract][Full Text] [Related]  

  • 8. IVOX with gradual permissive hypercapnia: a new management technique for respiratory failure.
    Zwischenberger JB; Nguyen TT; Tao W; Bush PE; Cox CS; Traber DL; Herndon DN; Bidani A
    J Surg Res; 1994 Jul; 57(1):99-105. PubMed ID: 8041157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Conceptual and design features of a practical, clinically effective intravenous mechanical blood oxygen/carbon dioxide exchange device (IVOX).
    Mortensen JD; Berry G
    Int J Artif Organs; 1989 Jun; 12(6):384-9. PubMed ID: 2777397
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stragegies to reduce surface area requirements for carbon dioxide removal for an intravenacaval gas exchange device.
    Tao W; Bidani A; Cardenas VJ; Niranjan SC; Zwischenberger JB
    ASAIO J; 1995; 41(3):M567-72. PubMed ID: 8573869
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intravascular membrane oxygenation and carbon dioxide removal with IVOX: can improved design and permissive hypercapnia achieve adequate respiratory support during severe respiratory failure?
    Zwischenberger JB; Cardenas VJ; Tao W; Niranjan SC; Clark JW; Bidani A
    Artif Organs; 1994 Nov; 18(11):833-9. PubMed ID: 7864733
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prolonged intracorporeal support of gas exchange with an intravenacaval oxygenator.
    Conrad SA; Eggerstedt JM; Morris VF; Romero MD
    Chest; 1993 Jan; 103(1):158-61. PubMed ID: 8417871
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Permissive hypercapnia and intravascular oxygenator in the treatment of patients with ARDS.
    Brunet F; Mira JP; Cerf C; Belghith M; Soubrane O; Termignon JL; Renaud B; Fierobe L; Hamy I; Monchi M
    Artif Organs; 1994 Nov; 18(11):826-32. PubMed ID: 7864732
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Present status of IVOX device].
    Terada Y
    Rinsho Kyobu Geka; 1994 Dec; 14(6):461-4. PubMed ID: 9423123
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new intravascular membrane oxygenator to augment blood gas transfer in patients with acute respiratory failure.
    Zwischenberger JB; Cox CS
    Tex Med; 1991 Dec; 87(12):60-3. PubMed ID: 1801294
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative gas transfer into and out of circulating venous blood by means of an intravenacaval oxygenator.
    Bagley B; Bagley A; Henrie J; Froerer C; Brohamer J; Burkart J; Mortensen JD
    ASAIO Trans; 1991; 37(3):M413-5. PubMed ID: 1751214
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The intravascular oxygenator (IVOX): preliminary results of a new means of performing extrapulmonary gas exchange.
    Gentilello LM; Jurkovich GJ; Gubler KD; Anardi DM; Heiskell R
    J Trauma; 1993 Sep; 35(3):399-404. PubMed ID: 8371298
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An intravenacaval blood gas exchange (IVCBGE) device. A preliminary report.
    Mortensen JD
    ASAIO Trans; 1987; 33(3):570-3. PubMed ID: 3118923
    [No Abstract]   [Full Text] [Related]  

  • 19. Improved gas exchange performance of the intravascular oxygenator by active blood mixing.
    Tao W; Schroeder T; Bidani A; Cardenas VJ; Nguyen PD; Bradford DW; Traber DL; Zwischenberger JB
    ASAIO J; 1994; 40(3):M527-32. PubMed ID: 8555572
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early results of intravascular oxygenation.
    Kallis P; al-Saady NM; Bennett ED; Treasure T
    Eur J Cardiothorac Surg; 1993; 7(4):206-10. PubMed ID: 8481258
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.