These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 7865628)

  • 1. A manual spectrophotometric method for the measurement of serum sodium and potassium by enzyme activation.
    Mazzachi RD; Mazzachi BC; Berry MN
    Eur J Clin Chem Clin Biochem; 1994 Sep; 32(9):709-17. PubMed ID: 7865628
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Enzymatic determination of potassium in serum.
    Berry MN; Mazzachi RD; Pejakovic M; Peake MJ
    Clin Chem; 1989 May; 35(5):817-20. PubMed ID: 2720976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Results of multicenter evaluation of reagents for determination of sodium, potassium and chloride ions using enzyme activation].
    Ehrhardt V; Baadenhuijsen H; Brenna S; Browne M; Garcia-Beltrán L; Hellsing K; Külpmann WR; Paschen K; Pascual-Mostaza C; Pei P
    Wien Klin Wochenschr Suppl; 1992; 192():12-21. PubMed ID: 1502819
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Evaluation of enzymatic methods for the determination of plasma sodium and potassium using the Hitachi 747 analytic system].
    Pei P; Cigler C; Vonderschmitt DJ
    Schweiz Med Wochenschr; 1991 Dec; 121(50):1883-6. PubMed ID: 1759149
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Enzymatic determination of sodium in serum.
    Berry MN; Mazzachi RD; Pejakovic M; Peake MJ
    Clin Chem; 1988 Nov; 34(11):2295-8. PubMed ID: 3141085
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Enzymatic determination of sodium, potassium and chloride in plasma].
    Chalas J; Francoual J; Lindenbaum A
    Ann Biol Clin (Paris); 1994; 52(5):333-9. PubMed ID: 7856932
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Exogenous interferences with Jaffe creatinine assays: addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods.
    Srisawasdi P; Chaichanajarernkul U; Teerakanjana N; Vanavanan S; Kroll MH
    J Clin Lab Anal; 2010; 24(3):123-33. PubMed ID: 20486190
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurements of sodium and potassium in newborns and prematures by ion-selective electrodes and flame photometry: influence of lipid and protein content of blood.
    Kau N; Günther M; Fahnenstich H; Kowalewski S; Bartmann P
    Acta Anaesthesiol Scand Suppl; 1995; 107():107-11. PubMed ID: 8599260
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes.
    Hübl W; Wejbora R; Shafti-Keramat I; Haider A; Hajdusich P; Bayer PM
    Clin Chem; 1994 Aug; 40(8):1528-31. PubMed ID: 8044991
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ion chromatography as potential reference methodology for the determination of total sodium and potassium in human serum.
    Thienpont LM; Van Nuwenborg JE; Stöckl D
    J Chromatogr A; 1995 Jul; 706(1-2):443-50. PubMed ID: 7640776
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chromogenic ionophore-based methods for spectrophotometric assay of sodium and potassium in serum and plasma.
    Kumar A; Chapoteau E; Czech BP; Gebauer CR; Chimenti MZ; Raimondo O
    Clin Chem; 1988 Sep; 34(9):1709-12. PubMed ID: 3416420
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reliability of the Hitachi sodium and potassium electrodes assessed.
    Winkel P; Wilken M; Christiansen J; Buch B
    Clin Chem; 1985 Mar; 31(3):457-9. PubMed ID: 3971568
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of protein on the determination of sodium, potassium and chloride in serum by Ektachem DT 60 with the DTE module; evaluation with special attention to a possible protein error by flame atomic emission spectrometry and ion-selective electrodes; proposals to their calibration.
    Külpmann WR
    J Clin Chem Clin Biochem; 1989 Oct; 27(10):815-24. PubMed ID: 2600555
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enzymatic spectrophotometric determination of sodium and potassium ions in serum or urine: a simple and satisfactory alternative to the use of flame photometry or ion-selective electrodes.
    Berry MN; Mazzachi RD; Peake MJ
    J Int Fed Clin Chem; 1991 Feb; 3(1):18-23. PubMed ID: 10149119
    [No Abstract]   [Full Text] [Related]  

  • 15. Intermethod variability of sodium and potassium results: patients' sera and commercially available control sera.
    Cattozzo G; Fabi A; Franzini C
    Eur J Clin Chem Clin Biochem; 1997 May; 35(5):387-92. PubMed ID: 9189744
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of potassium by dry reagent carrier technology: a multicentre evaluation.
    Paschen K; Hagemann P; Lang HR; Cortes M; Weidemann G; Toffaletti J; Burritt M; Leinberger R; Tritschler W; Ramstetter E
    Eur J Clin Chem Clin Biochem; 1993 Aug; 31(8):545-52. PubMed ID: 8218590
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of moderate hypercholesterolemia on recognition of hypernatremia using indirect measurements of serum sodium and potassium concentrations.
    Naskalski JW; Solnica B; Gernand W
    Clin Lab; 2007; 53(7-8):441-7. PubMed ID: 17821948
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Frozen human serum reference material for standardization of sodium and potassium measurements in serum or plasma by ion-selective electrode analyzers.
    Gunaratna PC; Koch WF; Paule RC; Cormier AD; D'Orazio P; Greenberg N; O'Connell KM; Malenfant A; Okorodudu AO; Miller R
    Clin Chem; 1992 Aug; 38(8 Pt 1):1459-65. PubMed ID: 1643715
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of candidate reference methods based on ion chromatography for determination of total sodium, potassium, calcium and magnesium in serum through comparison with flame atomic emission and absorption spectrometry.
    Thienpont LM; Van Nuwenborg JE; Reinauer H; Stöckl D
    Clin Biochem; 1996 Dec; 29(6):501-8. PubMed ID: 8939396
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of serum electrolyte results by Technicon's Flame III and Flame IV AutoAnalyser system.
    Jacklyn CL; Kriz CD; MacAulay MA
    Clin Biochem; 1978 Feb; 11(1):10-5. PubMed ID: 630697
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.