130 related articles for article (PubMed ID: 7865948)
1. Silicone-fat differentiation in the breast: exploiting the bright-fat phenomenon in fast spin-echo MR imaging.
Hiramatsu H; Mulkern RV; Oshio K; Waitzkin E; Williamson DS; O'Connor N; Adams DF; Jolesz FA
J Magn Reson Imaging; 1994; 4(6):868-71. PubMed ID: 7865948
[TBL] [Abstract][Full Text] [Related]
2. Differentiation of silicone gel from water and fat in MR phase imaging of protons at 0.064 T.
Derby KA; Frankel SD; Kaufman L; Carlson JW; Mineyev MI; Occhipinti KA; Friedenthal R
Radiology; 1993 Nov; 189(2):617-20. PubMed ID: 8210399
[TBL] [Abstract][Full Text] [Related]
3. Combination of chemical suppression techniques for dual suppression of fat and silicone at diffusion-weighted MR imaging in women with breast implants.
Koh DM; Blackledge M; Burns S; Hughes J; Stemmer A; Kiefer B; Leach MO; Collins DJ
Eur Radiol; 2012 Dec; 22(12):2648-53. PubMed ID: 22706913
[TBL] [Abstract][Full Text] [Related]
4. Silicone-specific imaging using an inversion-recovery-prepared fast three-point Dixon technique.
Ma J; Choi H; Stafford RJ; Miller MJ
J Magn Reson Imaging; 2004 Mar; 19(3):298-302. PubMed ID: 14994297
[TBL] [Abstract][Full Text] [Related]
5. Why fat is bright in RARE and fast spin-echo imaging.
Henkelman RM; Hardy PA; Bishop JE; Poon CS; Plewes DB
J Magn Reson Imaging; 1992; 2(5):533-40. PubMed ID: 1392246
[TBL] [Abstract][Full Text] [Related]
6. Silicone breast implant rupture: comparison between three-point Dixon and fast spin-echo MR imaging.
Gorczyca DP; Schneider E; DeBruhl ND; Foo TK; Ahn CY; Sayre JW; Shaw WW; Bassett LW
AJR Am J Roentgenol; 1994 Feb; 162(2):305-10. PubMed ID: 8310916
[TBL] [Abstract][Full Text] [Related]
7. Water-silicone separated volumetric MR acquisition for rapid assessment of breast implants.
Madhuranthakam AJ; Smith MP; Yu H; Shimakawa A; Reeder SB; Rofsky NM; McKenzie CA; Brittain JH
J Magn Reson Imaging; 2012 May; 35(5):1216-21. PubMed ID: 22247050
[TBL] [Abstract][Full Text] [Related]
8. Fat suppression with short inversion time inversion-recovery and chemical-shift selective saturation: a dual STIR-CHESS combination prepulse for turbo spin echo pulse sequences.
Tanabe K; Nishikawa K; Sano T; Sakai O; Jara H
J Magn Reson Imaging; 2010 May; 31(5):1277-81. PubMed ID: 20432368
[TBL] [Abstract][Full Text] [Related]
9. Silicone breast implants in vivo: MR imaging.
Gorczyca DP; Sinha S; Ahn CY; DeBruhl ND; Hayes MK; Gausche VR; Shaw WW; Bassett LW
Radiology; 1992 Nov; 185(2):407-10. PubMed ID: 1410346
[TBL] [Abstract][Full Text] [Related]
10. Selective MR imaging of silicone with the three-point Dixon technique.
Schneider E; Chan TW
Radiology; 1993 Apr; 187(1):89-93. PubMed ID: 8451442
[TBL] [Abstract][Full Text] [Related]
11. Novel rapid fat suppression strategy with spectrally selective pulses.
Peng Q; McColl RW; Wang J; Weatherall PT
Magn Reson Med; 2005 Dec; 54(6):1569-74. PubMed ID: 16217781
[TBL] [Abstract][Full Text] [Related]
12. MR imaging of breast implants.
Gorczyca DP
Magn Reson Imaging Clin N Am; 1994 Nov; 2(4):659-72. PubMed ID: 7489315
[TBL] [Abstract][Full Text] [Related]
13. A flexible fast spin echo triple-echo Dixon technique.
Son JB; Hwang KP; Madewell JE; Bayram E; Hazle JD; Low RN; Ma J
Magn Reson Med; 2017 Mar; 77(3):1049-1057. PubMed ID: 26982770
[TBL] [Abstract][Full Text] [Related]
14. Image quality and diagnostic performance of silicone-specific breast MRI.
Kim SH; Lipson JA; Moran CJ; Shimakawa A; Kuo J; Ikeda DM; Daniel BL
Magn Reson Imaging; 2013 Nov; 31(9):1472-8. PubMed ID: 23895871
[TBL] [Abstract][Full Text] [Related]
15. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.
Kirchgesner T; Perlepe V; Michoux N; Larbi A; Vande Berg B
Diagn Interv Imaging; 2018 Jan; 99(1):23-28. PubMed ID: 29054404
[TBL] [Abstract][Full Text] [Related]
16. Improved fat suppression using multipeak reconstruction for IDEAL chemical shift fat-water separation: application with fast spin echo imaging.
Kijowski R; Woods MA; Lee KS; Takimi K; Yu H; Shimakawa A; Brittain JH; Reeder SB
J Magn Reson Imaging; 2009 Feb; 29(2):436-42. PubMed ID: 19161199
[TBL] [Abstract][Full Text] [Related]
17. [Fast spin echo imaging of vertebral metastasis: comparison of fat suppression techniques (FSE-CHESS, STIR-FSE)].
Scarabino T; Giannatempo GM; Popolizio T; Scarale MG; Cammisa M; Salvolini U
Radiol Med; 1996 Sep; 92(3):180-5. PubMed ID: 8975299
[TBL] [Abstract][Full Text] [Related]
18. Rapid fat suppression in MRI of the breast with short binomial pulses.
Morrell GR
J Magn Reson Imaging; 2006 Nov; 24(5):1172-6. PubMed ID: 17036329
[TBL] [Abstract][Full Text] [Related]
19. Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: implications for the bright fat phenomenon in fast spin-echo imaging.
Williamson DS; Mulken RV; Jakab PD; Jolesz FA
Magn Reson Med; 1996 Apr; 35(4):506-13. PubMed ID: 8992200
[TBL] [Abstract][Full Text] [Related]
20. Comparison of the artifacts caused by metallic implants in breast MRI using dual-echo dixon versus conventional fat-suppression techniques.
Le Y; Kipfer HD; Majidi SS; Holz S; Lin C
AJR Am J Roentgenol; 2014 Sep; 203(3):W307-14. PubMed ID: 25148189
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]