181 related articles for article (PubMed ID: 7868141)
1. Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models.
Wang L; Patterson R
IEEE Trans Biomed Eng; 1995 Feb; 42(2):141-8. PubMed ID: 7868141
[TBL] [Abstract][Full Text] [Related]
2. A finite-element study of the effects of electrode position on the measured impedance change in impedance cardiography.
Wang Y; Haynor DR; Kim Y
IEEE Trans Biomed Eng; 2001 Dec; 48(12):1390-401. PubMed ID: 11759920
[TBL] [Abstract][Full Text] [Related]
3. Imaging of thoracic blood volume changes during the heart cycle with electrical impedance using a linear spot-electrode array.
Hoetink AE; Faes TJ; Marcus JT; Kerkkamp HJ; Heethaar RM
IEEE Trans Med Imaging; 2002 Jun; 21(6):653-61. PubMed ID: 12166862
[TBL] [Abstract][Full Text] [Related]
4. Computational modelling of blood-flow-induced changes in blood electrical conductivity and its contribution to the impedance cardiogram.
Trakic A; Akhand M; Wang H; Mason D; Liu F; Wilson S; Crozier S
Physiol Meas; 2010 Jan; 31(1):13-33. PubMed ID: 19940342
[TBL] [Abstract][Full Text] [Related]
5. EIT images of ventilation: what contributes to the resistivity changes?
Zhang J; Patterson RP
Physiol Meas; 2005 Apr; 26(2):S81-92. PubMed ID: 15798249
[TBL] [Abstract][Full Text] [Related]
6. The contribution of the lungs to thoracic impedance measurements: a simulation study based on a high resolution finite difference model.
Yang F; Patterson RP
Physiol Meas; 2007 Jul; 28(7):S153-61. PubMed ID: 17664633
[TBL] [Abstract][Full Text] [Related]
7. Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography.
Zhang J; Patterson R
Physiol Meas; 2010 Aug; 31(8):S45-56. PubMed ID: 20647615
[TBL] [Abstract][Full Text] [Related]
8. Estimation of current leakage in left and right ventricular conductance volumetry using a dynamic finite element model.
Gopakumaran B; Petre JH; Sturm B; White RD; Murray PA
IEEE Trans Biomed Eng; 2000 Nov; 47(11):1476-86. PubMed ID: 11077741
[TBL] [Abstract][Full Text] [Related]
9. Influence of physiological sources on the impedance cardiogram analyzed using 4D FEM simulations.
Ulbrich M; Mühlsteff J; Leonhardt S; Walter M
Physiol Meas; 2014 Jul; 35(7):1451-68. PubMed ID: 24901446
[TBL] [Abstract][Full Text] [Related]
10. Induced-current electrical impedance tomography: a 2-D theoretical simulation.
Zlochiver S; Rosenfeld M; Abboud S
IEEE Trans Med Imaging; 2003 Dec; 22(12):1550-60. PubMed ID: 14649745
[TBL] [Abstract][Full Text] [Related]
11. Stroke volume estimation in heart failure patients using bioimpedance: a realistic simulation of the forward problem.
Sokolovsky RE; Zlochiver S; Abboud S
Physiol Meas; 2008 Jun; 29(6):S139-49. PubMed ID: 18544809
[TBL] [Abstract][Full Text] [Related]
12. Transthoracic impedance: differences between men and women with implications for impedance cardiography.
Frey MA; Doerr BM; Miles DS
Aviat Space Environ Med; 1982 Dec; 53(12):1190-2. PubMed ID: 7159339
[TBL] [Abstract][Full Text] [Related]
13. Impedance imaging of lung ventilation: do we need to account for chest expansion?
Adler A; Guardo R; Berthiaume Y
IEEE Trans Biomed Eng; 1996 Apr; 43(4):414-20. PubMed ID: 8626190
[TBL] [Abstract][Full Text] [Related]
14. Use of impedance ratio for the continuous measurement of stroke volume of a valveless pouch used as a cardiac-assist device.
Geddes LA; Janas W; Badylak SF
IEEE Trans Biomed Eng; 1992 Mar; 39(3):310-3. PubMed ID: 1555862
[TBL] [Abstract][Full Text] [Related]
15. End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change.
Hinz J; Hahn G; Neumann P; Sydow M; Mohrenweiser P; Hellige G; Burchardi H
Intensive Care Med; 2003 Jan; 29(1):37-43. PubMed ID: 12528020
[TBL] [Abstract][Full Text] [Related]
16. Electric field plethysmography signals of the human thorax as determined by a 2-D FE-model.
Nopp P; Pfützner H; Bögl K; Nakesch H; Ruhsam C
Med Prog Technol; 1995-1996; 21(3):135-45. PubMed ID: 8776710
[TBL] [Abstract][Full Text] [Related]
17. Anterior-posterior impedance cardiography: a new approach to accurate, non-invasive monitoring of cardiac function.
Babbs CF
Cardiovasc Eng; 2010 Jun; 10(2):52-65. PubMed ID: 20204513
[TBL] [Abstract][Full Text] [Related]
18. The measurement of cardia output by the thoracic impedance method.
Adamicza A; Tutsek L; Nagy S
Acta Physiol Hung; 1988; 71(3):395-408. PubMed ID: 3421117
[TBL] [Abstract][Full Text] [Related]
19. Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data.
Nebuya S; Mills GH; Milnes P; Brown BH
Physiol Meas; 2011 Dec; 32(12):1953-67. PubMed ID: 22048128
[TBL] [Abstract][Full Text] [Related]
20. Relations between components of impedance cardiogram analyzed by means of finite element model and sensitivity theorem.
Wtorek J
Ann Biomed Eng; 2000; 28(11):1352-61. PubMed ID: 11212953
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]