164 related articles for article (PubMed ID: 7869178)
21. Reevaluating the Icterus Index Cutoff of a Jaffé Creatinine Method.
Alvarez YF; Kelliher MT; Hubbard JA; Nerenz RD; Cervinski MA
J Appl Lab Med; 2022 Sep; 7(5):1151-1157. PubMed ID: 35899580
[TBL] [Abstract][Full Text] [Related]
22. A study of interferences in routine methods for creatinine measurement.
Kenny D
Scand J Clin Lab Invest Suppl; 1993; 212():43-7. PubMed ID: 8465153
[TBL] [Abstract][Full Text] [Related]
23. Kinetic serum creatinine assays. II. A critical evaluation and review.
Bowers LD; Wong ET
Clin Chem; 1980 Apr; 26(5):555-61. PubMed ID: 7020989
[TBL] [Abstract][Full Text] [Related]
24. Prime time for enzymatic creatinine methods in pediatrics.
Cobbaert CM; Baadenhuijsen H; Weykamp CW
Clin Chem; 2009 Mar; 55(3):549-58. PubMed ID: 19168555
[TBL] [Abstract][Full Text] [Related]
25. Development of an automated kinetic Jaffé method designed to minimise bilirubin interference in plasma creatinine assays.
Knapp ML; Mayne PD
Clin Chim Acta; 1987 Sep; 168(2):239-46. PubMed ID: 3677419
[No Abstract] [Full Text] [Related]
26. Effect of detergent on kinetic Jaffé-method assay of creatinine.
Bergman A; Ohman G
Clin Chem; 1980 Nov; 26(12):1729-32. PubMed ID: 7428157
[TBL] [Abstract][Full Text] [Related]
27. Effects of interferents on the kinetic Jaffé reaction and an enzymatic colorimetric test for serum creatinine concentration determination in cats, cows, dogs and horses.
Jacobs RM; Lumsden JH; Taylor JA; Grift E
Can J Vet Res; 1991 Apr; 55(2):150-4. PubMed ID: 1884294
[TBL] [Abstract][Full Text] [Related]
28. Negative interference in a kinetic Jaffé method for serum creatinine determination.
Cruickshank AM; Ballantyne FC; Shenkin A
Ann Clin Biochem; 1988 Jan; 25 ( Pt 1)():112-3. PubMed ID: 3355083
[No Abstract] [Full Text] [Related]
29. Ultrafiltration of serum to eliminate bilirubin interference in the kinetic Jaffé determination of creatinine.
Hardeman D; Backer ET
Clin Chem; 1991 Nov; 37(11):2010-1. PubMed ID: 1934481
[No Abstract] [Full Text] [Related]
30. [Elimination of bilirubin interference on creatinine determination (kinetic Jaffé method) using bilirubin oxidase].
Matsushita M; Maehata E; Aoki Y
Rinsho Byori; 1986 Jun; 34(6):694-8. PubMed ID: 3747210
[No Abstract] [Full Text] [Related]
31. Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent.
Guder WG; Hoffmann GE; Hubbuch A; Poppe WA; Siedel J; Price CP
J Clin Chem Clin Biochem; 1986 Nov; 24(11):889-902. PubMed ID: 3806017
[TBL] [Abstract][Full Text] [Related]
32. The effect of neonatal hyperbilirubinemia on the measurement of plasma creatinine.
Feld LG; Langford DJ; Schwartz GJ
Clin Pediatr (Phila); 1984 Mar; 23(3):154-6. PubMed ID: 6697621
[TBL] [Abstract][Full Text] [Related]
33. Effect of bilirubin on serum creatinine measurement by the kinetic Jaffe method.
Osberg IM
Clin Chem; 1979 Feb; 25(2):335. PubMed ID: 759032
[No Abstract] [Full Text] [Related]
34. Bilirubin interference with the kinetic Jaffé method for serum creatinine.
Daugherty NA; Hammond KB; Osberg IM
Clin Chem; 1978 Feb; 24(2):392-3. PubMed ID: 627087
[No Abstract] [Full Text] [Related]
35. Bilirubin and metamizol do not interfere with the randox enzymatic creatinine test. An evaluation of a new enzymatic creatinine determination method.
Harmoinen AP
Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):975-6. PubMed ID: 8986403
[TBL] [Abstract][Full Text] [Related]
36. A robust procedure for the automated measurement of total serum bilirubin using potassium ferricyanide.
O'Leary N; Pembroke A; Duggan PF
Ann Clin Biochem; 1993 Mar; 30 ( Pt 2)():175-9. PubMed ID: 8466149
[TBL] [Abstract][Full Text] [Related]
37. Creatinine and automatic analysers in relation to icteric specimens.
Blijenberg BG; Liesting EC; Zwang L
Eur J Clin Chem Clin Biochem; 1992 Nov; 30(11):779-84. PubMed ID: 1489851
[TBL] [Abstract][Full Text] [Related]
38. Glucose Interference in Serum and Urine Samples with Various Creatinine Concentrations Measured by the Jaffe Kinetic Method.
Choosongsang P; Bhornsrivathanyou N; Aiadsakun P; Choosongsang P; Bodhikul A; Yamsuwan Y; Sriwimol W; Soonthornpun S
EJIFCC; 2023 Apr; 34(1):57-65. PubMed ID: 37124654
[TBL] [Abstract][Full Text] [Related]
39. Modification of Jaffe's kinetic method decreases bilirubin interference: A preliminary report.
Vaishya R; Arora S; Singh B; Mallika V
Indian J Clin Biochem; 2010 Jan; 25(1):64-6. PubMed ID: 23105886
[TBL] [Abstract][Full Text] [Related]
40. [Kinetic assay of creatinine with the Gemsaec-Fast-Analyzer; comparison with the Fuller's earth method (author's transl].
Knoll E; Rebel FC; Wisser H
J Clin Chem Clin Biochem; 1978 Apr; 16(4):239-44. PubMed ID: 641451
[TBL] [Abstract][Full Text] [Related]