41. Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve. Lee H; Tatsumi E; Taenaka Y ASAIO J; 2008; 54(1):25-30. PubMed ID: 18204312 [TBL] [Abstract][Full Text] [Related]
42. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity. Lee H; Homma A; Taenaka Y Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477 [TBL] [Abstract][Full Text] [Related]
43. Role of vortices in cavitation formation in the flow at the closure of a bileaflet mitral mechanical heart valve. Li CP; Chen SF; Lo CW; Lu PC J Artif Organs; 2012 Mar; 15(1):57-64. PubMed ID: 22015913 [TBL] [Abstract][Full Text] [Related]
45. Causes and formation of cavitation in mechanical heart valves. Graf T; Reul H; Detlefs C; Wilmes R; Rau G J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S49-64. PubMed ID: 8061870 [TBL] [Abstract][Full Text] [Related]
46. Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals. Lee H; Akagawa E; Tatsumi E; Taenaka Y J Artif Organs; 2008; 11(2):60-6. PubMed ID: 18604610 [TBL] [Abstract][Full Text] [Related]
48. Time-frequency analysis of transient pressure signals for a mechanical heart valve cavitation study. Yu AA; White JA; Hwang NH ASAIO J; 1998; 44(5):M475-9. PubMed ID: 9804476 [TBL] [Abstract][Full Text] [Related]
49. Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation. Chandran KB; Aluri S Ann Biomed Eng; 1997; 25(6):926-38. PubMed ID: 9395039 [TBL] [Abstract][Full Text] [Related]
50. Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase. Cheon GJ; Chandran KB J Biomech Eng; 1994 Nov; 116(4):452-9. PubMed ID: 7869721 [TBL] [Abstract][Full Text] [Related]
51. Flow visualization in mechanical heart valves: occluder rebound and cavitation potential. Kini V; Bachmann C; Fontaine A; Deutsch S; Tarbell JM Ann Biomed Eng; 2000 Apr; 28(4):431-41. PubMed ID: 10870900 [TBL] [Abstract][Full Text] [Related]
52. Closing behavior of the mechanical heart valve in a total artificial heart. Lee HS; Tsukiya T; Homma A; Taenaka Y; Tatsumi E; Takano H J Artif Organs; 2003; 6(1):37-41. PubMed ID: 14598123 [TBL] [Abstract][Full Text] [Related]
53. Observation and quantification of cavitation on a mechanical heart valve with an electro-hydraulic total artificial heart. Lee H; Taenaka Y Int J Artif Organs; 2006 Mar; 29(3):303-7. PubMed ID: 16685674 [TBL] [Abstract][Full Text] [Related]
55. In-vivo prediction of cavitation near a Medtronic Hall valve. Johansen P; Andersen TS; Hasenkam JM; Nygaard H J Heart Valve Dis; 2004 Jul; 13(4):651-8. PubMed ID: 15311874 [TBL] [Abstract][Full Text] [Related]
56. Transcranial Doppler ultrasound signals associated with prosthetic heart valves: an in vitro study. Mackay TG; Georgiadis D; Grosset DG; Kelman AW; Lees KR; Wheatley DJ J Heart Valve Dis; 1995 Jul; 4(4):414-9. PubMed ID: 7582153 [TBL] [Abstract][Full Text] [Related]
57. Influence of viscosity and pressure on prosthetic valve regurgitation. Pantalos GM; Sharp MK Int J Artif Organs; 1993 Mar; 16(3):151-4. PubMed ID: 8314639 [TBL] [Abstract][Full Text] [Related]
58. Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing. Lee H; Homma A; Tatsumi E; Taenaka Y J Artif Organs; 2009; 12(2):105-10. PubMed ID: 19536627 [TBL] [Abstract][Full Text] [Related]
59. Study of an acoustic technique to detect cavitation produced by a tilting disc valve. Herman BA; Porter JM; Carey RF J Heart Valve Dis; 1996 Jan; 5(1):90-6. PubMed ID: 8834731 [TBL] [Abstract][Full Text] [Related]