These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 7869722)

  • 41. Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2008; 54(1):25-30. PubMed ID: 18204312
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity.
    Lee H; Homma A; Taenaka Y
    Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Role of vortices in cavitation formation in the flow at the closure of a bileaflet mitral mechanical heart valve.
    Li CP; Chen SF; Lo CW; Lu PC
    J Artif Organs; 2012 Mar; 15(1):57-64. PubMed ID: 22015913
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Occluder closing behavior: a key factor in mechanical heart valve cavitation.
    Wu ZJ; Wang Y; Hwang NH
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S25-33; discussion S33-4. PubMed ID: 8061868
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Causes and formation of cavitation in mechanical heart valves.
    Graf T; Reul H; Detlefs C; Wilmes R; Rau G
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S49-64. PubMed ID: 8061870
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals.
    Lee H; Akagawa E; Tatsumi E; Taenaka Y
    J Artif Organs; 2008; 11(2):60-6. PubMed ID: 18604610
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Mechanical heart valve cavitation.
    Johansen P
    Expert Rev Med Devices; 2004 Sep; 1(1):95-104. PubMed ID: 16293013
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Time-frequency analysis of transient pressure signals for a mechanical heart valve cavitation study.
    Yu AA; White JA; Hwang NH
    ASAIO J; 1998; 44(5):M475-9. PubMed ID: 9804476
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation.
    Chandran KB; Aluri S
    Ann Biomed Eng; 1997; 25(6):926-38. PubMed ID: 9395039
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase.
    Cheon GJ; Chandran KB
    J Biomech Eng; 1994 Nov; 116(4):452-9. PubMed ID: 7869721
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Flow visualization in mechanical heart valves: occluder rebound and cavitation potential.
    Kini V; Bachmann C; Fontaine A; Deutsch S; Tarbell JM
    Ann Biomed Eng; 2000 Apr; 28(4):431-41. PubMed ID: 10870900
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Closing behavior of the mechanical heart valve in a total artificial heart.
    Lee HS; Tsukiya T; Homma A; Taenaka Y; Tatsumi E; Takano H
    J Artif Organs; 2003; 6(1):37-41. PubMed ID: 14598123
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Observation and quantification of cavitation on a mechanical heart valve with an electro-hydraulic total artificial heart.
    Lee H; Taenaka Y
    Int J Artif Organs; 2006 Mar; 29(3):303-7. PubMed ID: 16685674
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Statistical characteristics of mechanical heart valve cavitation in accelerated testing.
    Wu C; Hwang NH; Lin YK
    J Heart Valve Dis; 2004 Jul; 13(4):659-66. PubMed ID: 15311875
    [TBL] [Abstract][Full Text] [Related]  

  • 55. In-vivo prediction of cavitation near a Medtronic Hall valve.
    Johansen P; Andersen TS; Hasenkam JM; Nygaard H
    J Heart Valve Dis; 2004 Jul; 13(4):651-8. PubMed ID: 15311874
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Transcranial Doppler ultrasound signals associated with prosthetic heart valves: an in vitro study.
    Mackay TG; Georgiadis D; Grosset DG; Kelman AW; Lees KR; Wheatley DJ
    J Heart Valve Dis; 1995 Jul; 4(4):414-9. PubMed ID: 7582153
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Influence of viscosity and pressure on prosthetic valve regurgitation.
    Pantalos GM; Sharp MK
    Int J Artif Organs; 1993 Mar; 16(3):151-4. PubMed ID: 8314639
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing.
    Lee H; Homma A; Tatsumi E; Taenaka Y
    J Artif Organs; 2009; 12(2):105-10. PubMed ID: 19536627
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Study of an acoustic technique to detect cavitation produced by a tilting disc valve.
    Herman BA; Porter JM; Carey RF
    J Heart Valve Dis; 1996 Jan; 5(1):90-6. PubMed ID: 8834731
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Cavitation damage of pyrolytic carbon in mechanical heart valves.
    Kafesjian R; Howanec M; Ward GD; Diep L; Wagstaff LS; Rhee R
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S2-7. PubMed ID: 8061867
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.